Robotically-actuated catheters are being employed in endovascular interventions for their improved maneuverability and steering precision over conventional catheters. Fluoroscopy is commonly used to guide such medical devices during interventions. Motivated by the limitations and hazards associated with fluoroscopy, this study investigates the use of ultrasound images as a viable alternative for the real-time visualization of a robotic catheter. In order to validate the proposed approach, an integrated system is developed which employs a two-dimensional ultrasound-based tracking algorithm to detect and track a magnetically-actuated catheter. By using Euler-Bernoulli beam theory to describe the motion of the catheter and a closed-loop control, the magnetic field steers the robotic catheter in two-dimensional space. Experiments show that the model is able to describe the catheter deflections with a fitting error of R-2 = 0.96. Closed-loop steering experiments show a maximum positioning error of 0.46 mm. Our study demonstrates the possibility to accurately steer a magnetic catheter using two-dimensional ultrasound images.
引用
收藏
页码:61 / 66
页数:6
相关论文
共 50 条
  • [1] Ultrasound Tracking and Closed-Loop Control of a Magnetically-Actuated Biomimetic Soft Robot
    Anjos de Oliveira, Artur Joao
    Batista, Jorge
    Misra, Sarthak
    Venkiteswaran, Venkatasubramanian Kalpathy
    [J]. 2022 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2022, : 3422 - 3428
  • [2] Constant flow rate micropumping using closed-loop control of magnetically actuated nanofluid
    Doganay, Serkan
    Cetin, Levent
    Ezan, Mehmet Akif
    Turgut, Alpaslan
    [J]. TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2023, 45 (08) : 1558 - 1569
  • [3] Two-dimensional phase imaging based on closed-loop feedback control
    Watanabe, Eriko
    Toshima, Miki
    Fujikawa, Chiemi
    [J]. OPTICS AND PHOTONICS FOR INFORMATION PROCESSING V, 2011, 8134
  • [4] Closed-loop feedback-control system for improved tracking in magnetically actuated micromirrors
    Pannu, S
    Chang, C
    Muller, RS
    Pisano, AP
    [J]. 2000 IEEE/LEOS INTERNATIONAL CONFERENCE ON OPTICAL MEMS, 2000, : 107 - 108
  • [5] Grasping Using Magnetically-Actuated Tentacle Catheter: A Proof-Of-Concept Study
    Sikorski, Jakub
    Rutting, Etienne S. A. A. M.
    Misra, Sarthak
    [J]. 2018 7TH IEEE INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB2018), 2018, : 609 - 614
  • [6] Two-dimensional numerical analysis of a rectangular closed-loop thermosiphon
    Desrayaud, Gilles
    Fichera, Alberto
    Lauriat, Guy
    [J]. APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 187 - 196
  • [7] Closed-loop Force Control of a Pneumatic Gripper Actuated by Two Pressure Regulators
    Romeo, Rocco A.
    Fiorio, Luca
    Avila-Mireles, Edwin J.
    Cannella, Ferdinando
    Metta, Giorgio
    Pucci, Daniele
    [J]. 2019 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2019, : 7157 - 7162
  • [8] Closed-Loop Time-Optimal Attitude Maneuvering of Magnetically Actuated Spacecraft
    Pooya Sekhavat
    Hui Yan
    Andrew Fleming
    I. Michael Ross
    Kyle T. Alfriend
    [J]. The Journal of the Astronautical Sciences, 2011, 58 : 81 - 97
  • [9] Closed-Loop Time-Optimal Attitude Maneuvering of Magnetically Actuated Spacecraft
    Sekhavat, Pooya
    Yan, Hui
    Fleming, Andrew
    Ross, I. Michael
    Alfriend, Kyle T.
    [J]. JOURNAL OF THE ASTRONAUTICAL SCIENCES, 2011, 58 (01): : 81 - 97
  • [10] Nested PCR in magnetically actuated circular closed-loop PCR microchip system
    Khoi Seng Lok
    Peter Peng Foo Lee
    Yien Chian Kwok
    Nam-Trung Nguyen
    [J]. Microchimica Acta, 2012, 177 : 111 - 117