Harmonic wideband simultaneous dual-frequency MR Elastography

被引:0
|
作者
Sango Solanas, Pilar [1 ]
Tse Ve Koon, Kevin [1 ]
Ratiney, Helene [1 ]
Millioz, Fabien [1 ]
Caussy, Cyrielle [2 ,3 ]
Beuf, Olivier [1 ]
机构
[1] Univ Claude Bernard Lyon 1, CNRS, UJM St Etienne, Univ Lyon,INSA Lyon,Inserm,U1206,CREATIS,UMR 5220, Lyon, France
[2] Univ Claude Bernard Lyon 1, Univ Lyon, CarMen Lab, INSERM,INRA,INSA Lyon, Pierre Benite, France
[3] Hop Lyon Sud, Dept Endocrinol Diabet & Nutr, Hosp Civils Lyon, Pierre Benite, France
关键词
MR elastography; multifrequency; phase offset undersampling; MAGNETIC-RESONANCE ELASTOGRAPHY; VISCOELASTIC POWERLAW BEHAVIOR; FRACTAL NETWORK DIMENSION; NONINVASIVE ASSESSMENT; HEPATIC-FIBROSIS; SHEAR PROPERTIES; LIVER; MULTIFREQUENCY; BREAST; TISSUE;
D O I
10.1002/nbm.4442
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Magnetic resonance elastography (MRE) is used to non-invasively quantify viscoelastic properties of tissues based on the measurement of propagation characteristics of shear waves. Because some of these viscoelastic parameters show a frequency dependence, multifrequency analysis allows us to measure the wave propagation dispersion, leading to a better characterization of tissue properties. Conventionally, motion encoding gradients (MEGs) oscillating at the same frequency as the mechanical excitation encode motion. Hence, multifrequency data is usually obtained by sequentially repeating monochromatic wave excitations experiments at different frequencies. The result is that the total acquisition time is multiplied by a factor corresponding to the number of repetitions of monofrequency experiments, which is a major limitation of multifrequency MRE. In order to make it more accessible, a novel single-shot harmonic wideband dual-frequency MRE method is proposed. Two superposed shear waves of different frequencies are simultaneously generated and propagate in a sample. Trapezoidal oscillating MEGs are used to encode mechanical vibrations having frequencies that are an odd multiple of the MEG frequency. The number of phase offsets is optimized to reduce the acquisition time. For this purpose, a sampling method not respecting the Shannon theorem is used to produce a controlled temporal aliasing that allows us to encode both frequencies without any additional examination time. Phantom experiments were run to compare conventional monofrequency MRE with the single-shot dual-frequency MRE method and showed excellent agreement between the reconstructed shear storage moduli G '. In addition, dual-frequency MRE yielded an increased signal-to-noise ratio compared with conventional monofrequency MRE acquisitions when encoding the high frequency component. The novel proposed multifrequency MRE method could be applied to simultaneously acquire more than two frequency components, reducing examination time. Further studies are needed to confirm its applicability in preclinical and clinical models.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Short echo time dual-frequency MR Elastography with Optimal Control RF pulses
    Pilar Sango-Solanas
    Kevin Tse Ve Koon
    Eric Van Reeth
    Helene Ratiney
    Fabien Millioz
    Cyrielle Caussy
    Olivier Beuf
    [J]. Scientific Reports, 12
  • [2] Short echo time dual-frequency MR Elastography with Optimal Control RF pulses
    Sango-Solanas, Pilar
    Koon, Kevin Tse Ve
    Van Reeth, Eric
    Ratiney, Helene
    Millioz, Fabien
    Caussy, Cyrielle
    Beuf, Olivier
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [3] Dual-frequency MR elastography to differentiate between inflammation and fibrosis of the liver: Comparison with histopathology
    Sofue, Keitaro
    Onoda, Minori
    Tsurusaki, Masakatsu
    Morimoto, Daisuke
    Yada, Norihisa
    Kudo, Masatoshi
    Murakami, Takamichi
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (04) : 1053 - 1064
  • [4] Wideband Dual-Frequency Antenna With Large Frequency Ratio
    Feng, Li Ying
    Leung, Kwok Wa
    [J]. IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2019, 67 (03) : 1981 - 1986
  • [5] Editorial for "Dual-Frequency MR Elastography to Differentiate Between Inflammation and Fibrosis of the Liver: Comparison With Histopathology"
    Runge, Jurgen Henk
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (05) : 1594 - 1595
  • [6] Dual-frequency and dual-polarisation wideband microstrip antenna
    Kim, Y
    Yun, W
    Yoon, Y
    [J]. ELECTRONICS LETTERS, 1999, 35 (17) : 1399 - 1400
  • [7] Dual-Frequency Transducer with a Wideband PVDF Receiver for Contrast-Enhanced, Adjustable Harmonic Imaging
    Kim, Jinwook
    Lindsey, Brooks D.
    Li, Sibo
    Dayton, Paul A.
    Jiang, Xiaoning
    [J]. HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2017, 2017, 10170
  • [8] Acquisition Efficiency and Technical Repeatability of Dual-Frequency 3D Vector MR Elastography of the Liver
    Qiu, Caixin
    Glaser, Kevin J.
    Owusu, Nana
    Li, Jiahui
    Wu, Hao
    Venkatesh, Sudhakar K.
    Manduca, Armando
    Ehman, Richard L.
    Yin, Meng
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024,
  • [9] Wideband dual-frequency stacked microstrip patch antenna
    de Haaij, DM
    Joubert, J
    Odendaal, W
    [J]. MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2001, 31 (04) : 289 - 292
  • [10] Design of a wideband dual-frequency notched microstrip antenna
    Palit, SK
    Hamadi, A
    Tan, D
    [J]. IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM - ANTENNAS: GATEWAYS TO THE GLOBAL NETWORK, VOLS 1-4, 1998, : 2351 - 2354