摘要
Light yield nonproportionality and the intrinsic resolution of some low atomic number scintillators were studied by means of the Wide Angle Compton Coincidence (WACC) technique. The plastic and liquid scintillator response to Compton electrons was measured in the energy range of 10 keV up to 4 MeV, whereas a CaF2:Eu sample was scanned from 3 keV up to 1 MeV. The nonproportionality of the CaF2:Eu light yield has characteristics typical for inorganic scintillators of the multivalent halides group, whereas tested organic scintillators show steeply increasing nonproportionality without saturation point. This is in contrast to the behavior of all known inorganic scintillators having their nonproportionality curves at saturation above energies between tens and several hundred keV.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] A Technique for Measuring the Energy Resolution of Low-Z Scintillators
    Roemer, Katja
    Pausch, Guntram
    Herbach, Claus-Michael
    Kong, Yong
    Lentering, Ralf
    Plettner, Cristina
    Stein, Juergen
    Moszynski, Marek
    Swiderski, Lukasz
    Szczesniak, Tomasz
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 6 - 11
  • [2] Measurement of Compton edge position in low-Z scintillators
    Swiderski, Lukasz
    Moszynski, Marek
    Czarnacki, Wiestaw
    Iwanowska, Joanna
    Syntfeld-Kazuch, Agnieszka
    Szczesniak, Tomasz
    Pausch, Guntram
    Plettner, Cristina
    Roemer, Katja
    RADIATION MEASUREMENTS, 2010, 45 (3-6) : 605 - 607
  • [3] Low-z test for interacting dark energy
    Goncalves, R. S.
    Carvalho, G. C.
    Alcaniz, J. S.
    PHYSICAL REVIEW D, 2015, 92 (12)
  • [4] ELECTRON IONIZATION OF SOME LOW-Z IONS IN THE PLANE-WAVE BORN APPROXIMATION
    MCGUIRE, EJ
    PHYSICAL REVIEW A, 1982, 25 (01): : 192 - 203
  • [5] ELECTRON BACKSCATTERING FROM LOW-Z THICK ABSORBERS
    KALEFEZRA, J
    HOROWITZ, YS
    MACK, JM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 195 (03): : 587 - 595
  • [6] ELECTRON-ENERGY LOSS CHEMICAL MAPPING OF LOW-Z ELEMENTS IN BIOLOGICAL SECTIONS
    JEANGUILLAUME, C
    TENCE, M
    TREBBIA, P
    COLLIEX, C
    SCANNING ELECTRON MICROSCOPY, 1983, : 745 - 756
  • [7] PROTON STOPPING POWERS IN SOME LOW-Z ELEMENTS
    SHARADA, KS
    RADIATION RESEARCH, 1993, 136 (03) : 335 - 340
  • [8] NONLINEAR RESPONSE OF SI DETECTORS FOR LOW-Z IONS
    LENNARD, WN
    GEISSEL, H
    WINTERBON, KB
    PHILLIPS, D
    ALEXANDER, TK
    FORSTER, JS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 248 (2-3): : 454 - 460
  • [9] LOW TEMPERATURE RESPONSE OF SOME SCINTILLATORS
    WERKHEISER, AH
    MILLER, TG
    NUCLEAR INSTRUMENTS & METHODS, 1969, 75 (01): : 167 - +
  • [10] LOW-Z ABLATOR TARGETS FOR ELECTRON-BEAM FUSION
    SWEENEY, MA
    CLAUSER, MJ
    APPLIED PHYSICS LETTERS, 1975, 27 (09) : 483 - 486