Investigation of the possibility of increasing the sensitivity of a microwave radiometer

被引:0
|
作者
Luchinin, Alexander [1 ]
Malygin, Ivan [1 ]
机构
[1] URFU, Dept Radio Elect & Commun, Ekaterinburg 620002, Russia
来源
29TH INTERNATIONAL CRIMEAN CONFERENCE: MICROWAVE & TELECOMMUNICATION TECHNOLOGY (CRIMICO'2019) | 2019年 / 30卷
关键词
D O I
10.1051/itmconf/20193013007
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The results of a sensitivity study of various types of quadratic detectors for a microwave radiometer are presented, both with and without a low-noise amplifier. A low-noise amplifier with a gain of 60 dB and a bandwidth of 1 GHz at a central frequency of 4 GHz was developed and studied.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] A new algorithm on increasing the sensitivity of microwave radiometer based on nonlinear prediction
    Fei, Gao
    ADVANCES IN SPACE RESEARCH, 2008, 42 (10) : 1743 - 1746
  • [2] INVESTIGATION OF THE SPECTRAL CHANNEL SENSITIVITY FIELDS OF AN IR RADIOMETER AND THE POSSIBILITY OF EQUALIZING THEM
    POVARKOV, VI
    SAMKOV, VM
    SOVIET JOURNAL OF OPTICAL TECHNOLOGY, 1980, 47 (09): : 517 - 518
  • [3] ON THE SENSITIVITY OF FIRE DETECTION BY A MICROWAVE RADIOMETER
    Dvorak, Petr
    Zvanovec, Stanislav
    2013 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2013, : 402 - 405
  • [4] Fluctuation sensitivity models of microwave radiometer
    Abdirasul, Tilekbek
    Alekseev, Egor
    Minenko, Dmitry
    Ubaichin, Anton
    Zhuk, Gregory
    PROCEEDINGS OF THE IV INTERNATIONAL RESEARCH CONFERENCE INFORMATION TECHNOLOGIES IN SCIENCE, MANAGEMENT, SOCIAL SPHERE AND MEDICINE (ITSMSSM 2017), 2017, 72 : 10 - 12
  • [5] Design and implementation of high sensitivity microwave radiometer
    Liu, Jie
    Zhang, Ruiqi
    Sun, Guangmin
    Zhu, Yuxuan
    Gao, Wenya
    Liu, Yixuan
    AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS, 2023, 170
  • [6] METHOD OF INCREASING THE NOISE-IMMUNITY OF A MICROWAVE RADIOMETER
    DANILOV, VI
    MODEEV, YI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1979, 22 (06) : 1604 - 1606
  • [7] Sensitivity of a microwave radiometer with digital beam-forming
    Zhang, Jing
    Li, Qingxia
    Guo, Wei
    Zhu, Yaoting
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2009, 37 (12): : 5 - 8
  • [8] A POSSIBILITY OF INCREASING THE SENSITIVITY OF DEFOCUSED SPECKLE PHOTOGRAPHY
    GEORGIEVA, J
    DENTCHEVA, M
    OPTICA APPLICATA, 1985, 15 (03) : 309 - 314
  • [9] INCREASING THE SENSITIVITY OF AN IF-MODULATED RADIOMETER BY REGULATION OF HETERODYNE POWER
    GELFER, AG
    LAPIDUS, AD
    ROMANYCHEV, YN
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1986, 29 (04) : 875 - 877
  • [10] INCREASING SENSITIVITY OF BEAM MICROWAVE SPECTROSCOPES
    KRUPNOV, AF
    SKVORTSOV, VA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1964, (01) : 230 - &