Wetting and drying of cover-zone concrete

被引:16
|
作者
McCarter, WJ [1 ]
Watson, D [1 ]
机构
[1] BLYTH & BLYTH ASSOCIATES,EDINBURGH,MIDLOTHIAN,SCOTLAND
关键词
D O I
10.1680/istbu.1997.29312
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The influence of wetting and drying on cover-zone concrete was studied, Plain ordinary Portland cement (OPC) concretes and OPC with partial replacement with pulverized fuel ash, ground granulated blast furnace slag, micro-silica and metakaolin were used in the experimental programme, The effects of water-binder ratio and initial curing were examined, After curing, samples were subjected to a cycle of drying followed by water infiltration to investigate the movement and distribution of moisture within the surface 100 mm of the concrete samples, Use was made of electrical monitoring techniques, together with cumulative volumetric gain and loss.
引用
收藏
页码:227 / 236
页数:10
相关论文
共 50 条
  • [1] Depth-related variation in conductivity to study cover-zone concrete during wetting and drying
    Chrisp, TM
    McCarter, WJ
    Starrs, G
    Basheer, PAM
    Blewett, J
    [J]. CEMENT & CONCRETE COMPOSITES, 2002, 24 (05): : 415 - 426
  • [2] Discretized conductivity measurements to study wetting and drying of cover zone concrete
    McCarter, WJ
    Chrisp, TM
    Ezirim, HC
    [J]. ADVANCES IN CEMENT RESEARCH, 1998, 10 (04) : 195 - 202
  • [3] Field monitoring of electrical conductivity of cover-zone concrete
    McCarter, WJ
    Chrisp, TM
    Starrs, G
    Basheer, PAM
    Blewett, J
    [J]. CEMENT & CONCRETE COMPOSITES, 2005, 27 (7-8): : 809 - 817
  • [4] Monitoring water and ionic penetration into cover-zone concrete
    McCarter, WJ
    Chrisp, M
    [J]. ACI MATERIALS JOURNAL, 2000, 97 (06) : 668 - 674
  • [5] DEVELOPMENTS IN MONITORING TECHNIQUES FOR DURABILITY ASSESSMENT OF COVER-ZONE CONCRETE
    McCarter, W. J.
    Chrisp, T. M.
    Starrs, G.
    Holmes, N.
    Basheer, L.
    Basheer, M.
    Nanukuttan, S. V.
    [J]. ADVANCES IN CONCRETE STRUCTURAL DURABILITY: PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON DURABILITY OF CONCRETE STRUCTURES ICDCS2010, 2010, : 137 - 146
  • [6] Tower Type Sensors for Monitoring Corrosion Risk in Cover-zone Concrete
    Lu, Shuang
    Ba, Hengjing
    Wang, Anjian
    Yang, Yingzi
    [J]. MANUFACTURING SCIENCE AND ENGINEERING, PTS 1-5, 2010, 97-101 : 4305 - +
  • [7] Transient moisture profiles in cover-zone concrete during water absorption
    McCarter, W. J.
    Alaswad, G.
    Suryanto, B.
    [J]. CEMENT AND CONCRETE RESEARCH, 2018, 108 : 167 - 171
  • [8] Near-surface sensors for condition monitoring of cover-zone concrete
    McCarter, WJ
    Chrisp, TM
    Butler, A
    Basheer, PAM
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2001, 15 (2-3) : 115 - 124
  • [9] Monitoring the influence of water and ionic ingress on cover-zone concrete subjected to repeated absorption
    McCarter, WJ
    [J]. CEMENT CONCRETE AND AGGREGATES, 1996, 18 (01): : 55 - 63
  • [10] Influence of Different European Cements on the Hydration of Cover-Zone Concrete during the Curing and Postcuring Periods
    McCarter, W. J.
    Starrs, G.
    Adamson, A.
    Chrisp, T. M.
    Basheer, P. A. M.
    Nanukuttan, S.
    Srinivasan, S.
    Green, C.
    [J]. JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2013, 25 (09) : 1335 - 1343