Nafion/Multi-wall Carbon Nanotubes Composite Modified Glassy Carbon Electrode for Sensitive Determination of Bilirubin

被引:7
|
作者
Filik, Hayati [1 ]
Avan, Asiye A. [1 ]
Aydar, Sevda [1 ]
机构
[1] Istanbul Univ, Dept Chem, Fac Engn, TR-34320 Istanbul, Turkey
关键词
Bilirubin; biomolecule; graphene; urine analysis; voltammetry; ELECTROCHEMICAL OXIDATION; ENZYMATIC METHOD; SERUM BILIRUBIN; REDUCTION; NANOCOMPOSITE; NANOPARTICLES; BILIVERDIN; BIOSENSOR; PIGMENTS;
D O I
10.2174/1573413711666150529202436
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A composite picture of multi-wall carbon nanotubes (MWCNTs) with Nafion (NF) cation exchange membrane is prepared by cast deposition on glassy carbon electrodes. A sensitive electrochemical sensor for the detection of bilirubin (BR) at the NF/MWCNTs hybrid modified glassy carbon electrode was offered. The electrochemical behaviors of bilirubin at the NF/MWCNTs hybrid electrode were studied in acetone containing sulfuric acid as the supporting electrolyte. Compared with bare glassy carbon electrode (GCE), the proposed integrated sensor, improved analytical performance characteristics in the electrochemical oxidation of bilirubin. The electrochemistry of bilirubin on NF/MWCNTs hybrid electrodes were studied by electrochemical impedance spectroscopy, cyclic voltammetry (CV) and square-wave voltammetry (SWV). The oxidation peak current of bilirubin obtained at the NF/MWCNTs modified GC electrode was 10 times higher than that of the unmodified glassy carbon electrode. To optimize the experimental conditions, a linear calibration plot for bilirubin was obtained between 0.8 mu M and 10 mu M with the detection limit of 0.014 mu M. Finally, the proposed sensor was successfully employed to determine bilirubin in human urine samples.
引用
收藏
页码:784 / 791
页数:8
相关论文
共 50 条
  • [1] Nafion/multi-wall carbon nanotubes composite film coated glassy carbon electrode for sensitive determination of caffeine
    Yang, Suling
    Yang, Ran
    Li, Gang
    Qu, Lingbo
    Li, Jianjun
    Yu, Lanlan
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2010, 639 (1-2) : 77 - 82
  • [2] Voltammetric determination of theophylline at a Nafion/multi-wall carbon nanotubes composite film-modified glassy carbon electrode
    Yang, Suling
    Yang, Ran
    Li, Gang
    Li, Jianjun
    Qu, Lingbo
    [J]. JOURNAL OF CHEMICAL SCIENCES, 2010, 122 (06) : 919 - 926
  • [3] VOLTAMMETRIC DETERMINATION OF METHYLPARABAN IN COSMETICS USING A MULTI-WALL CARBON NANOTUBES/NAFION COMPOSITE MODIFIED GLASSY CARBON ELECTRODE
    Luo, Peili
    Liu, Jie
    Li, Yamin
    Miao, Yurui
    Ye, Baoxian
    [J]. ANALYTICAL LETTERS, 2012, 45 (16) : 2445 - 2454
  • [4] Voltammetric determination of theophylline at a Nafion/multi-wall carbon nanotubes composite film-modified glassy carbon electrode
    Suling Yang
    Ran Yang
    Gang Li
    Jianjun Li
    Lingbo Qu
    [J]. Journal of Chemical Sciences, 2010, 122 : 919 - 926
  • [5] Sensitive Adsorption Stripping Voltammetric Determination of Reserpine by a Glassy Carbon Electrode Modified with Multi-Wall Carbon Nanotubes
    Huajie Zhang
    Kangbing Wu
    [J]. Microchimica Acta, 2005, 149 : 73 - 78
  • [6] Sensitive adsorption stripping voltammetric determination of reserpine by a glassy carbon electrode modified with multi-wall carbon nanotubes
    Zhang, HJ
    Wu, KB
    [J]. MICROCHIMICA ACTA, 2005, 149 (1-2) : 73 - 78
  • [7] Electrocatalytic Oxidation of Trimethoprim at Multi-wall Carbon Nanotubes-Nafion Modified Glassy Carbon Electrode and Its Electrochemical Determination
    Gao Zuo-Ning
    Sun Yu-Qin
    You Wei
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 37 (04) : 553 - 557
  • [8] Electrochemical Sensor for Determination of Fenitrothion at Multi-wall Carbon Nanotubes Modified Glassy Carbon Electrode
    Tefera, M.
    Tessema, M.
    Admassie, S.
    Mehretie, S.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2015, 2 (02): : 139 - 150
  • [9] Voltammetric behavior and determination of phenylephrine at a glassy carbon electrode modified with multi-wall carbon nanotubes
    Zhu, Yuan-hai
    Zhang, Zhi-ling
    Zhao, Wei
    Pang, Dai-wen
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 119 (01) : 308 - 314
  • [10] Electrochemical behaviours of scutellarin at multi-wall carbon nanotubes modified glassy carbon electrode
    Cai, Zhuo
    Yue, Weichao
    Gan, Jingni
    Peng, Yue
    He, Xiaoliang
    [J]. PROGRESS IN MATERIALS AND PROCESSES, PTS 1-3, 2013, 602-604 : 239 - 242