Fine Tilt Tuning of a Laparoscopic Camera by Local Magnetic Actuation: Two-Port Nephrectomy Experience on Human Cadavers

被引:16
|
作者
Simi, Massimiliano [1 ,3 ]
Pickens, Ryan [2 ]
Menciassi, Arianna [1 ]
Herrell, S. Duke [2 ]
Valdastri, Pietro [1 ,3 ]
机构
[1] Scuola Super Sant Anna, Biorobot Inst, Pisa, Italy
[2] Vanderbilt Univ, Med Ctr, Nashville, TN 37235 USA
[3] Vanderbilt Univ, Dept Mech Engn, STORM Lab, Nashville, TN 37235 USA
关键词
robotic surgery; biomedical engineering; urology; magnetic surgical instruments; INTRAABDOMINAL CAMERA; SURGERY; INSTRUMENTATION; SYSTEM;
D O I
10.1177/1553350612462458
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background. The magnetic surgical camera is an emerging technology having the potential to improve visualization without taking up port site space. However, tilting the point of view downward/upward can be done only by constantly applying a pressure on the abdomen. This study aims to test the hypothesis that the novel concept of local magnetic actuation (LMA) is able to increase the tilt range available for a magnetic camera without the need for deforming the abdominal wall. The hypothesis that 2-port laparoscopic nephrectomy in fresh tissue human cadavers could be performed by using the LMA camera is also tested. Methods. First, the 2 cameras were separately inserted, anchored, and moved inside the inflated abdomen. Tilting angles were quantified by image analysis while intra-abdominal pressure changes were monitored. Then, 5 two-port nephrectomies were performed by using the LMA camera while collecting quantitative outcomes. Results. The magnetic camera required a constant pressure on the magnetic handle to achieve an average +/- 20 degrees tilt from the horizontal position, with an average of 7 mm Hg loss of intra-abdominal pressure. The LMA camera allowed for 75 degrees of tilt from the horizontal position with a resolution of +/- 1 degrees, without any need to deform the abdomen. All the nephrectomies were completed successfully within an average time of 11 minutes. Conclusion. LMA is an effective strategy to provide magnetic cameras with wide-range and high-resolution vertical motion without the need to deform the abdominal wall.
引用
收藏
页码:385 / 394
页数:10
相关论文
共 3 条
  • [1] FINE TILT TUNING OF A LAPAROSCOPIC CAMERA BY LOCAL MAGNETIC ACTUATION: TWO-PORT LAPAROSCOPIC NEPHRECTOMY EXPERIENCE ON HUMAN CADAVERS
    Pickens, Ryan
    Simi, Massimiliano
    Valdastri, Pietro
    Herrell, Duke
    JOURNAL OF UROLOGY, 2013, 189 (04): : E339 - E339
  • [2] Two-Port Laparoscopic Cholecystectomy: 18 Patients Human Experience Using the Dynamic Laparoscopic NovaTract Retractor
    Sucandy, Iswanto
    Nadzam, Geoffrey
    Duffy, Andrew J.
    Roberts, Kurt E.
    JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES, 2016, 26 (08): : 625 - 629
  • [3] Another Option for Laparoscopic Living Donor Nephrectomy: A Single Center Experience Comparing Two-Port Versus Hand-Assisted Technique
    Cho, Hyuk Jin
    Choi, Yong Sun
    Bae, Woong Jin
    Bae, Jang Ho
    Hong, Sung-Hoo
    Lee, Ji Youl
    Kim, Sae Woong
    Hwang, Tae-Kon
    Cho, Yong-Hyun
    JOURNAL OF ENDOUROLOGY, 2013, 27 (05) : 587 - 591