Development of a spiral type heat exchanger for ground source heat pump system

被引:18
|
作者
Suzuki, Michiya [1 ]
Yoneyama, Kazuyuki [2 ]
Amemiya, Saya [2 ]
Oe, Motoaki [3 ]
机构
[1] Tohoku Gakuin Univ, 1-13-1 Chuo, Tagajou City 9858537, Japan
[2] Shimizu Corp, Koto Ku, 3-4-17 Etchujima, Tokyo 1358530, Japan
[3] Inoac Housing & Construct Mat Co Ltd, Atsuta Ku, 4-9-27 Taiho, Nagoya, Aichi 4560062, Japan
关键词
ground source heat pump system; ground heat exchanger; spiral type;
D O I
10.1016/j.egypro.2016.09.091
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In Japan, net Zero Energy Buildings are crucial for reducing energy use and environmental load to realize a sustainable society. Ground-source heat pump systems are a key technology for reducing energy consumption by air conditioning systems. There are two types of ground-source heat pump systems: "closed loop type" and "open loop type". In general, open loop type ground-source heat pump systems have better relative performance than closed loop type systems. However, pumping up underground water is prohibited in urban areas of Japan to prevent the ground surface level from sinking. Therefore, closed loop type systems are used more extensively in Japan. The typical and conventional heat exchangers used for closed loop type heat pump systems are of the "U tube" or "double U tube" types. However, neither type has a high heat exchange capacity per unit length. Thus, in this study, a spiral-type heat exchanger for a ground-source heat pump system is developed. The aim of the heat exchanger is to perform intensive heat-exchange in the aquifer layer near the ground surface (ten to twenty meters in depth). To use the underground water flow in order to facilitate intensive heat exchange, the length of the heat exchanger is planned to be inserted between ten and twenty meters below the surface into the upper part of the aquifer. The diameter of the spiral-type heat exchanger is determined such that a borehole machine for piles can be used for settlement of heat exchangers to reduce the construction cost. The performance of the heat exchanger is simulated under various flow rates and soil conditions using the numerical simulator "TOUGH2/EOS1." Based on the simulation and construction cost study, the cost-effectiveness of the spiral-type exchanger is made clear. (C) 2016 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:503 / 510
页数:8
相关论文
共 50 条
  • [1] Experimental and numerical investigation on a new type of heat exchanger in ground source heat pump system
    Xichen Liu
    Yimin Xiao
    Kiao Inthavong
    Jiyuan Tu
    [J]. Energy Efficiency, 2015, 8 : 845 - 857
  • [2] Experimental and numerical investigation on a new type of heat exchanger in ground source heat pump system
    Liu, Xichen
    Xiao, Yimin
    Inthavong, Kiao
    Tu, Jiyuan
    [J]. ENERGY EFFICIENCY, 2015, 8 (05) : 845 - 857
  • [3] Measured performance of a solar-ground source heat pump system with vertical double spiral coil ground heat exchanger
    Bi, Y.
    Chen, L.
    Wu, C.
    [J]. International Journal of Ambient Energy, 2001, 22 (01) : 3 - 11
  • [4] Study for the performance of a solar-ground source heat pump system with vertical double spiral coil ground heat exchanger
    Bi, YH
    Guo, TW
    Zhang, L
    Chen, LG
    [J]. PROCEEDINGS OF THE 3RD INTERNATIONAL SYMPOSIUM ON HEAT TRANSFER ENHANCEMENT AND ENERGY CONSERVATION, VOLS 1 AND 2, 2004, : 508 - 515
  • [5] Heat transfer analysis of underground U-type heat exchanger of ground source heat pump system
    Pei, Guihong
    Zhang, Liyin
    [J]. SPRINGERPLUS, 2016, 5
  • [6] Optimized Design of Ground-Source Heat Pump System Heat Exchanger
    Shi, Zhigang
    Song, Shangping
    Hu, Songtao
    [J]. PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 723 - 730
  • [7] Research on ground heat exchanger of Ground Source Heat Pump technique
    LIU Dong-sheng
    [J]. Global Geology, 2004, (02) : 196 - 199
  • [8] Operation characteristics and experience of a ground source heat pump system with a vertical ground heat exchanger
    Michopoulos, A.
    Zachariadis, T.
    Kyriakis, N.
    [J]. ENERGY, 2013, 51 : 349 - 357
  • [9] Using a capillary mat as a shallow heat exchanger for a ground source heat pump system
    Widiatmojo, Arif
    Gaurav, Shrestha
    Ishihara, Takeshi
    Yasukawa, Kasumi
    Uchida, Youhei
    Yoshioka, Mayumi
    Tomigashi, Akira
    [J]. ENERGY AND BUILDINGS, 2020, 209
  • [10] PERFORMANCE OF A SPIRAL GROUND HEAT-EXCHANGER FOR HEAT-PUMP APPLICATION
    SVEC, OJ
    PALMER, JHL
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1989, 13 (05) : 503 - 510