Comparison of Two Devices for Intraoperative Portal Venous Flow Measurement in Living-Donor Liver Transplantation: Transit Time Ultrasound and Conventional Doppler Ultrasound

被引:2
|
作者
Wang, H. -K. [1 ,2 ]
Chen, C. -Y. [2 ,3 ]
Lin, N. -C. [2 ,3 ]
Liu, C. -S. [2 ,3 ]
Loong, C. C. [2 ,3 ]
Lin, Y. -H. [1 ]
Lai, Y. -C. [1 ,2 ]
Chiou, H. -J. [1 ,2 ]
机构
[1] Taipei Vet Gen Hosp, Dept Radiol, 201,2nd Sec,Shih Pai Rd, Taipei 112, Taiwan
[2] Natl Yang Ming Univ, Sch Med, Taipei, Taiwan
[3] Taipei Vet Gen Hosp, Dept Surg, Taipei, Taiwan
关键词
CIRRHOSIS;
D O I
10.1016/j.transproceed.2018.01.037
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. Intraoperative portal venous flow measurement provides surgeons with instant guidance for portal flow modulation during living-donor liver transplantation (LDLT). In this study, we compared the agreement of portal flow measurement obtained by 2 devices: transit time ultrasound (TTU) and conventional Doppler ultrasound (CDU). Methods. Fifty-four recipients of LDLT underwent intraoperative measurement of portal flow after completion of vascular anastomosis of the implanted partial liver graft. Both TTU and CDU were used concurrently. Agreement of TTU and CDU was assessed by intraclass correlation coefficient using a model of 2-way random effects, absolute agreement, and single measurement. A Bland-Altman plot was applied to assess the variability between the 2 devices. Results. The mean, median, and range of portal venous flow was 1456, 1418, and 117 to 2776 mL/min according to TTU; and 1564, 1566, and 119 to 3216 mL/min according to CDU. The intraclass correlation coefficient of portal venous flow between TTU and CDU was 0.68 (95% confidence interval, 0.51-0.80). The Bland-Altman plots revealed an average variation of 4.8% between TTU and CDU but with a rather wide 95% confidence interval of variation ranging from 57.7% to 67.4%. Conclusions. Intraoperative TTU and CDU showed moderate agreement in portal flow measurement. However, a relatively wide range of variation exists between TTU and CDU, indicating that data obtained from the 2 devices may not be interchangeable.
引用
收藏
页码:1157 / 1159
页数:3
相关论文
共 50 条
  • [1] Measurement of liver volumes by portal vein flow by Doppler ultrasound in living donor liver transplantation
    Choi, Sang Hyun
    Kwon, Jae Hyun
    Kim, Kyoung Won
    Jang, Hye Young
    Kim, Ji Hye
    Kwon, Heon-Ju
    Lee, Jeongjin
    Song, Gi-Won
    Lee, Sung-Gyu
    [J]. CLINICAL TRANSPLANTATION, 2017, 31 (09)
  • [2] Intraoperative ultrasound guided portal venous thrombectomy in living donor liver transplantation recipient surgery
    Inoue, Yosuke
    Sugawara, Yasuhiko
    Tamura, Surnihito
    Makuuchi, Masatoshi
    [J]. TRANSPLANT INTERNATIONAL, 2008, 21 (05) : 428 - 433
  • [3] Predictive factors of intraoperative portal vein occlusion in pediatric living donor liver transplantation: Doppler ultrasound
    Cheng, YF
    Huang, TL
    Chen, TY
    Chen, YS
    Chen, CL
    [J]. LIVER TRANSPLANTATION, 2003, 9 (06) : C13 - C13
  • [4] Intraoperative Doppler ultrasound in living-related liver transplantation
    Huang, TL
    Cheng, YF
    Chen, CL
    Lee, TY
    Chen, TY
    Chen, YS
    Chiang, YC
    Eng, HL
    Wang, CC
    Wang, SH
    Lin, CL
    Cheung, HK
    Jawan, B
    [J]. TRANSPLANTATION PROCEEDINGS, 2000, 32 (07) : 2097 - 2098
  • [5] Portal hemodynamics in living-related liver transplantation: Quantitative measurement by Doppler ultrasound
    Huang, TL
    Cheng, YF
    Chen, TY
    Lee, TYC
    Lee, TY
    Chen, YS
    Chiang, YC
    Liu, PP
    Eng, HL
    Chen, CL
    [J]. TRANSPLANTATION PROCEEDINGS, 1998, 30 (07) : 3186 - 3187
  • [6] Doppler Ultrasound Evaluation of Postoperative Portal Vein Stenosis in Adult Living Donor Liver Transplantation
    Huang, T. L.
    Cheng, Y. F.
    Chen, T. Y.
    Tsang, L. L.
    Ou, H. Y.
    Yu, C. Y.
    Wang, C. C.
    Wang, S. H.
    Lin, C. L.
    Cheung, H. K.
    Eng, H. L.
    Jawan, B.
    Concejero, A. M.
    Chen, C. L.
    [J]. TRANSPLANTATION PROCEEDINGS, 2010, 42 (03) : 879 - 881
  • [7] The Role of Color Doppler Ultrasound in Living Donor Liver Transplantation
    Huang, Tung-Liang
    [J]. JOURNAL OF MEDICAL ULTRASOUND, 2008, 16 (03) : 177 - 187
  • [8] Optimal portal venous circulation for liver function after living-donor liver transplantation
    Yagi, S
    Iida, T
    Hori, T
    Taniguchi, K
    Yamagiwa, K
    Uemoto, S
    [J]. AMERICAN JOURNAL OF TRANSPLANTATION, 2005, 5 : 210 - 210
  • [9] Transvenous Variceal Embolization during or after Living-donor Liver Transplantation to Improve Portal Venous Flow
    Kim, Jin Hyoung
    Ko, Gi-Young
    Sung, Kyu-Bo
    Yoon, Hyun-Ki
    Kim, Kyung Rae
    Moon, Deok-Bog
    Lee, Sung-Gyu
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (11) : 1454 - 1459
  • [10] MEASUREMENT OF NORMAL PORTAL VENOUS-BLOOD FLOW BY DOPPLER ULTRASOUND
    BROWN, HS
    HALLIWELL, M
    QAMAR, M
    READ, AE
    EVANS, JM
    WELLS, PNT
    [J]. GUT, 1989, 30 (04) : 503 - 509