Effect of Heat Softening versus Ultrasonic Removal of Root-End Gutta-Percha on the Quality of Root-End Preparation for Endodontic Microsurgery

被引:1
|
作者
Ling, Zhiting [1 ]
Zheng, Ziting [1 ]
Zeng, Yuting [1 ]
Jiang, Lifang [1 ]
Wu, Yuan [1 ]
Wu, Buling [1 ]
Yan, Wenjuan [1 ]
机构
[1] Southern Med Univ, Nanfang Hosp, Dept Conservat & Endodont Dent, 1838 N Guangzhou Rd, Guangzhou 510515, Peoples R China
关键词
OUT BOND STRENGTH; CAVITY PREPARATION; FILLING MATERIALS; INTEGRITY; APICES; TEETH; LASER;
D O I
10.1155/2021/8320234
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This study is aimed at comparing the efficacy of heat softening and ultrasonic removal of root-end gutta-percha during retrograde preparation for root apical microsurgery. Recently extracted single-rooted premolars (n = 40) were prepared with standardized endodontically treated and root-end resection and then randomly divided into four groups that received root-end cavity preparation using four different instruments: a diamond-coated ultrasonic tip (AS3D; SACTEON, Paris, France), AS3D with the modified plugger of cordless heat carrier (MSE; B&L Biotech, Bala Cynwyd, PA, USA), stainless steel ultrasonic tip (Jetip-2; B&L Biotech, Bala Cynwyd, PA, USA), or Jetip-2 with MSE. The time required for root-end preparation was recorded. The root apex samples were examined by scanning electron microscopy to assess root surface microcracks and marginal integrity. The remnants of gutta-percha on the cavity walls were evaluated using a stereomicroscope. Statistical analysis was performed using Student's t-test and Wilcoxon rank-sum test (P < 0:05). Usage of MSE with Jetip-2 significantly reduced preparation time from 99:8 +/- 6:8 s to 32:4 +/- 1:0 s (P = 0:009), the number of microcracks from 42 to 13 (P = 0:036), and the remnants of gutta-percha from 80% to 20% (P = 0:041). Similar results were observed for AS3D with MSE. The heat softening of MSE was effective in cleaning gutta-percha, thus greatly improving the efficiency of the root-end preparation, thereby producing a root-end cavity with fewer microcracks and better marginal integrity.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Evaluation for cracks associated with ultrasonic root-end preparation of gutta-percha filled canals
    Beling, KL
    Marshall, JG
    Morgan, LA
    Baumgartner, JC
    JOURNAL OF ENDODONTICS, 1997, 23 (05) : 323 - 326
  • [2] Evaluation of Root-End Preparation with Two Different Endodontic Microsurgery Ultrasonic Tips
    Palma, Paulo J.
    Marques, Joana A.
    Casau, Margarida
    Santos, Andre
    Caramelo, Francisco
    Falacho, Rui I.
    Santos, Joao Miguel
    BIOMEDICINES, 2020, 8 (10) : 1 - 19
  • [3] Effect of various sealers with gutta-percha as root-end fillings on healing after replantation
    Ford, TRP
    Andreasen, JO
    Dorn, SO
    Kariyawasam, SP
    ENDODONTICS & DENTAL TRAUMATOLOGY, 1996, 12 (01): : 33 - 37
  • [4] ULTRASONIC ROOT-END PREPARATION .2. MICROLEAKAGE OF EBA ROOT-END FILLINGS
    SAUNDERS, WP
    SAUNDERS, EM
    GUTMANN, JL
    INTERNATIONAL ENDODONTIC JOURNAL, 1994, 27 (06) : 325 - 329
  • [5] The quality of ultrasonic root-end preparation: A quantitative study
    Lin, CP
    Chou, HG
    Kuo, JC
    Lan, WH
    JOURNAL OF ENDODONTICS, 1998, 24 (10) : 666 - 670
  • [6] A scanning electron microscopic evaluation of root surfaces and the gutta-percha interface following root-end resection in vitro
    Weston, GD
    Moule, AJ
    Bartold, PM
    INTERNATIONAL ENDODONTIC JOURNAL, 1999, 32 (06) : 450 - 458
  • [7] ULTRASONIC PREPARATION AND OBTURATION OF ROOT-END CAVITIES
    SULTAN, M
    FORD, TRP
    INTERNATIONAL ENDODONTIC JOURNAL, 1995, 28 (05) : 231 - 238
  • [8] Breakage of ultrasonic root-end preparation tips
    Walmsley, AD
    Lumley, PJ
    Johnson, WT
    Walton, RE
    JOURNAL OF ENDODONTICS, 1996, 22 (06) : 287 - 289
  • [9] EFFECTS OF ULTRASONIC ROOT-END CAVITY PREPARATION ON THE ROOT APEX
    ABEDI, HR
    VANMIERLO, BL
    WILDERSMITH, P
    TORABINEJAD, M
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1995, 80 (02): : 207 - 213
  • [10] The effect of ultrasonic removal of various root-end filling materials
    Pirani, C.
    Iacono, F.
    Chersoni, S.
    Sword, J.
    Pashley, D. H.
    Tay, F. R.
    Looney, S.
    Gandolfi, M. G.
    Prati, C.
    INTERNATIONAL ENDODONTIC JOURNAL, 2009, 42 (11) : 1015 - 1025