Improved reproducibility of high-resolution peripheral quantitative computed tomography for measurement of bone quality

被引:175
|
作者
MacNeil, Joshua A. [1 ]
Boyd, Steven K. [1 ]
机构
[1] Univ Calgary, Dept Mech & Mfg Engn, Schulich Sch Engn, Calgary, AB T2N 1N4, Canada
关键词
osteoporosis; densitometry; micro-computed tomography; reproducibility; bone;
D O I
10.1016/j.medengphy.2007.11.003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A human high-resolution peripheral quantitative computed tomography scanner (HR-pQCT) (XtremeCT, Scanco Medical, Switzerland) capable of measuring three important indicators of bone quality (micro-architectural morphology, mineralization and mechanical stiffness) has been developed. The goal of this study was to evaluate the reproducibility of male and female HR-pQCT in vivo measurements, and elucidate the causes of error in these measurements through a comparison with in vitro measurements. The best possible short-term reproducibility was found using a set of 10 in vitro measurements without repositioning, and a set of 10 with repositioning. Subsequently, in vivo measurements were performed on 15 male and 15 female subjects at baseline and follow-ups of I week and 4 months to determine the short- and long-term reproducibility of the system. In addition to the 2D area matching method used in the standard evaluation protocol, a custom developed 3D registration method was used to find the common region between repeated scans. The best possible reproducibility without movement artifacts and repositioning error was less than 0.5%, while the reproducibility with repositioning error was less than 1.5%. The in vivo reproducibility of density (< 1%), morphological (< 4.5%) and stiffness (< 3.5) measurements was consistently poorer than the reproducibility of cadaver measurements, presumably due to small movement artifacts and repositioning errors. Using 3D image registration, repositioning error was reduced on average by 23% and 8% for measurements of the radius and tibia sites, respectively. This study has provided bounds for the reproducibility of HR-pQCT to monitor bone quality longitudinally, and a basis for clinical study design to determine detectable changes. (C) 2007 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:792 / 799
页数:8
相关论文
共 50 条
  • [1] Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality
    MacNeil, Joshua A.
    Boyd, Steven K.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2007, 29 (10) : 1096 - 1105
  • [2] Accuracy of volumetric bone mineral density measurement in high-resolution peripheral quantitative computed tomography
    Sekhon, Kiranjit
    Kazakia, Galateia J.
    Burghardt, Andrew J.
    Hermannsson, Bryan
    Majumdar, Sharmila
    [J]. BONE, 2009, 45 (03) : 473 - 479
  • [3] Quality control for bone quality parameters affected by subject motion in high-resolution peripheral quantitative computed tomography
    Pauchard, Yves
    Liphardt, Anna-Maria
    Macdonald, Heather M.
    Hanley, David A.
    Boyd, Steven K.
    [J]. BONE, 2012, 50 (06) : 1304 - 1310
  • [4] High-Resolution Peripheral Quantitative Computed Tomography for Bone Evaluation in Inflammatory Rheumatic Disease
    Klose-Jensen, Rasmus
    Tse, Justin J.
    Keller, Kresten Krarup
    Barnabe, Cheryl
    Burghardt, Andrew J.
    Finzel, Stephanie
    Tam, Lai-Shan
    Hauge, Ellen-Margrethe
    Stok, Kathryn S.
    Manske, Sarah L.
    [J]. FRONTIERS IN MEDICINE, 2020, 7
  • [5] Bone Evaluation by High-Resolution Peripheral Quantitative Computed Tomography in Patients With Adrenal Incidentaloma
    Moraes, Aline Barbosa
    de Paula, Marcela Pessoa
    Paranhos-Neto, Francisco de Paula
    Ribeiro Cavalari, Emanuela Mello
    Cordeiro de Morais, Felipe Fernandes
    Carvalho Curi, Daniel Silva
    Cardoso Lima, Luis Felipe
    Carvalho de Mendonca, Laura Maria
    Fleiuss Farias, Maria Lucia
    Madeira, Miguel
    Vieira Neto, Leonardo
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2020, 105 (08): : E2726 - E2737
  • [6] In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography
    Boutroy, S
    Bouxsein, ML
    Munoz, F
    Delmas, PD
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2005, 90 (12): : 6508 - 6515
  • [7] Multicenter precision of cortical and trabecular bone quality measures assessed by high-resolution peripheral quantitative computed tomography
    Burghardt, Andrew J.
    Pialat, Jean-Baptiste
    Kazakia, Galateia J.
    Boutroy, Stephanie
    Engelke, Klaus
    Patsch, Janina M.
    Valentinitsch, Alexander
    Liu, Danmei
    Szabo, Eva
    Bogado, Cesar E.
    Belen Zanchetta, Maria
    McKay, Heather A.
    Shane, Elizabeth
    Boyd, Steven K.
    Bouxsein, Mary L.
    Chapurlat, Roland
    Khosla, Sundeep
    Majumdar, Sharmila
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2013, 28 (03) : 524 - 536
  • [8] Quantitative and Semiquantitative Bone Erosion Assessment on High-resolution Peripheral Quantitative Computed Tomography in Rheumatoid Arthritis
    Srikhum, Waraporn
    Virayavanich, Warapat
    Burghardt, Andrew J.
    Yu, Andrew
    Link, Thomas M.
    Imboden, John B.
    Li, Xiaojuan
    [J]. JOURNAL OF RHEUMATOLOGY, 2013, 40 (04) : 408 - 416
  • [9] High-resolution peripheral quantitative computed tomography in children with osteogenesis imperfecta
    David J. Fennimore
    Maria Digby
    Margaret Paggiosi
    Paul Arundel
    Nick J. Bishop
    Paul Dimitri
    Amaka C. Offiah
    [J]. Pediatric Radiology, 2020, 50 : 1781 - 1787
  • [10] High-resolution peripheral quantitative computed tomography in children with osteogenesis imperfecta
    Fennimore, David J.
    Digby, Maria
    Paggiosi, Margaret
    Arundel, Paul
    Bishop, Nick J.
    Dimitri, Paul
    Offiah, Amaka C.
    [J]. PEDIATRIC RADIOLOGY, 2020, 50 (12) : 1781 - 1787