Effects of glenosphere positioning on impingement-free internal and external rotation after reverse total shoulder arthroplasty

被引:66
|
作者
Li, Xinning [1 ]
Knutson, Zakary [1 ]
Choi, Daniel [1 ]
Lobatto, Daniel [1 ]
Lipman, Joseph [1 ]
Craig, Edward V. [1 ]
Warren, Russell F. [1 ]
Gulotta, Lawrence V. [1 ]
机构
[1] Hosp Special Surg, Div Sports Med & Shoulder Surg, New York, NY 10012 USA
关键词
Glenosphere position; reverse shoulder arthroplasty; internal rotation; external rotation; impingement; SCAPULAR IMPINGEMENT; ABDUCTION RANGE; CUFF TEAR; PROSTHESIS; ARTHRITIS; MOTION; BIOMECHANICS; REPLACEMENT; MODEL; JOINT;
D O I
10.1016/j.jse.2012.07.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Patients may experience a loss of internal rotation (IR) and external rotation (ER) after reverse total shoulder arthroplasty (RTSA). We hypothesized that alterations in the glenosphere position will affect the amount of impingement-free IR and ER. Materials and methods: Computed tomography (CT) scans of the scapula and humerus were obtained from 7 cadaveric specimens, and 3-dimensional reconstructions were created. RTSA models were virtually implanted into each specimen. The glenosphere position was determined in relation to the neutral position in 7 settings: medialization (5 mm), lateralization (10 mm), superior translation (6 mm), inferior translation (6 mm), superior tilt (20 degrees), and inferior tilt (15 degrees and 30 degrees). The humerus in each virtual model was allowed to freely rotate at a fixed scaption angle (0 degrees, 20 degrees, 40 degrees, and 60 degrees) until encountering bone-to-bone or bone-to-implant impingement (180 degrees of limitation). Measurements were recorded for each scaption angulation. Results: At 0 degrees scaption, only inferior translation, lateralization, and inferior tilt (30 degrees) allowed any impingement-free motion in IR and ER. At the midranges of scaption (20 degrees and 40 degrees), increased lateralization and inferior translation resulted in improved rotation. Supraphysiologic motion (>90 degrees rotation) was seen consistently at 60 degrees of scaption in IR. Superior translation (6 mm) resulted in no rotation at 0 degrees and 20 degrees of scaption for IR and ER. Conclusions: Glenosphere position significantly affected humeral IR and ER after RTSA. Superior translation resulted in significant restrictions on IR and ER. Optimal glenosphere positioning was achieved with inferior translation, inferior tilt, and lateralization in all degrees of scaption. Level of evidence: Basic Science Study, Computer Modeling. (C) 2013 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:807 / 813
页数:7
相关论文
共 50 条
  • [1] Influence of scapular neck length on the extent of impingement-free adduction after reverse total shoulder arthroplasty
    Arashiro, Yasuhara
    Izaki, Teruaki
    Miyake, Satoshi
    Shibata, Terufumi
    Yoshimura, Ichiro
    Yamamoto, Takuaki
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (01) : 185 - 191
  • [2] Optimal rotation and screw positioning for initial glenosphere baseplate fixation in reverse shoulder arthroplasty
    Parsons, Bradford O.
    Gruson, Konrad I.
    Accousti, Kenneth J.
    Klug, Raymond A.
    Flatow, Evan L.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (06) : 886 - 891
  • [3] Influence of subscapularis stiffness with glenosphere lateralization on physiological external rotation limits after reverse shoulder arthroplasty
    Linderman, Shannon E.
    Johnson, Joshua E.
    Anderson, Donald D.
    Patterson, Brendan M.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (11) : 2629 - 2637
  • [4] Glenosphere size in reverse shoulder arthroplasty: is larger better for external rotation and abduction strength?
    Mueller, Andreas M.
    Born, Marian
    Jung, Christian
    Flury, Matthias
    Kolling, Christoph
    Schwyzer, Hans-Kaspar
    Audige, Laurent
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (01) : 44 - 52
  • [5] Glenosphere size in reverse shoulder arthroplasty: is larger better for external rotation and abduction strength?
    Mueller, Andreas
    Born, Marian
    Jung, Christian
    Flury, Matthias
    Kolling, Christoph
    Schwyzer, Hans-Kaspar
    Audige, Laurent
    SWISS MEDICAL WEEKLY, 2018, 148 : 28S - 28S
  • [6] Extension of the shoulder is essential for functional internal rotation after reverse total shoulder arthroplasty
    Hochreiter, Bettina
    Wyss, Sabine
    Gerber, Christian
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (06) : 1166 - 1174
  • [7] Extension of the Shoulder is Essential for Functional Internal Rotation After Reverse Total Shoulder Arthroplasty
    Hochreiter, Bettina
    Wyss, Sabine
    Gerber, Christian
    SWISS MEDICAL WEEKLY, 2021, 151 : 10S - 10S
  • [8] Glenosphere dissociation after reverse shoulder arthroplasty
    Cusick, Michael C.
    Hussey, Michael M.
    Steen, Brandon M.
    Hartzler, Robert U.
    Clark, Rachel E.
    Cuff, Derek J.
    Cabezas, Andres F.
    Santoni, Brandon G.
    Frankle, Mark A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (07) : 1061 - 1068
  • [9] Analysis of impingement-free range of motion of the glenohumeral joint after reverse total shoulder arthroplasty using three different implant models
    Kim, Sung-Jae
    Jang, Seong-wook
    Jung, Koo-Hyun
    Kim, Yoon Sang
    Lee, Seung-Jin
    Yoo, Yon-sik
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2019, 24 (01) : 87 - 94
  • [10] Factors Influencing Functional Internal Rotation after Reverse Total Shoulder Arthroplasty
    Hochreiter, Bettina
    Hasler, Anita
    Hasler, Julian
    Kriechling, Philipp
    Borbas, Paul
    Gerber, Christian
    SWISS MEDICAL WEEKLY, 2021, 151 : 10S - 10S