Metrological Performances of a Plantar Pressure Measurement System

被引:31
|
作者
Saggin, Bortolino [1 ]
Scaccabarozzi, Diego [1 ]
Tarabini, Marco [1 ]
机构
[1] Politecn Milan, I-20133 Milan, Italy
关键词
Biomedical measurements; error compensation; gait analysis; plantar pressure; uncertainty; DISTRIBUTION BENEATH; REPEATABILITY; ACCURACY; VALUES; FOOT;
D O I
10.1109/TIM.2013.2245185
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Plantar pressure measurements provide useful information to diagnose a diverse range of foot disorders; unfortunately, the commercially available measurement systems are undesirably sensitive to several disturbances, but this aspect is mostly neglected in the literature. This paper describes the results of an experimental campaign aiming at the identification of pressure measuring system metrological performances, at system modeling, and at the implementation of correction procedures. The sensor model was implemented using the results of static and dynamic tests performed on a pedar-X plantar pressure measurement system. The static calibration was performed by analyzing the effect of temperature, single sensor coverage area, local curvature, tangential forces, long-term stability (creep), and sensor crosstalk on the system performances. The dynamic calibration was performed on an electrodynamic shaker, identifying the single sensor frequency response function and the hysteresis under different average loads. The dynamic sensor model is based on the Kelvin-Voigt model, which is representative of the viscoelastic behavior of the material. The model allowed us to compensate both the creep (i.e., the behavior under static loads) and the nonunitary frequency response function. A deconvolution-based algorithm has been proposed to compensate the sensor crosstalk effects, although its implementation requires additional investigations. Experimental results of bobbing and gait tests showed that, with the adoption of the proposed compensation algorithms, the force and center of pressure errors could be reduced by more than 50% of their initial values.
引用
收藏
页码:766 / 776
页数:11
相关论文
共 50 条
  • [1] Electronic measurement system of foot plantar pressure
    Klimiec, Ewa
    Piekarski, Jacek
    Zaraska, Wieslaw
    Jasiewicz, Barabara
    [J]. MICROELECTRONICS INTERNATIONAL, 2014, 31 (03) : 229 - 234
  • [2] Foot Plantar Pressure Measurement System: A Review
    Razak, Abdul Hadi Abdul
    Zayegh, Aladin
    Begg, Rezaul K.
    Wahab, Yufridin
    [J]. SENSORS, 2012, 12 (07) : 9884 - 9912
  • [3] A PORTABLE INSOLE PLANTAR PRESSURE MEASUREMENT SYSTEM
    WERTSCH, JJ
    WEBSTER, JG
    TOMPKINS, WJ
    [J]. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1992, 29 (01): : 13 - 18
  • [4] Development of Plantar Pressure Measurement System and Personal Classification Study based on Plantar Pressure Image
    Ho, Jong Gab
    Kim, Dae Gyeom
    Kim, Young
    Jang, Seung-wan
    Min, Se Dong
    [J]. KSII TRANSACTIONS ON INTERNET AND INFORMATION SYSTEMS, 2021, 15 (11): : 3875 - 3891
  • [5] The Comparative Study of the Circumstances of Plantar Pressure at Different Speed of Walking by Utilizing the Plantar Pressure Measurement System
    Gao, Yi
    [J]. INFORMATION COMPUTING AND APPLICATIONS, PT 2, 2010, 106 : 515 - 522
  • [6] An intelligent shoe-integrated system for plantar pressure measurement
    Chen, Meng
    Huang, Bufu
    Lee, Ka Keung
    Xu, Yangsheng
    [J]. 2006 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS, VOLS 1-3, 2006, : 416 - +
  • [7] Plantar pressure measurement system based on piezoelectric sensor: a review
    Li, Xiang
    Wang, Keyi
    Wang, Yan Lin
    Wang, Kui Cheng
    [J]. SENSOR REVIEW, 2022, 42 (02) : 241 - 249
  • [8] Foot Plantar Pressure Measurement System Using Optical Sensor
    Keatsamarn, Tanapon
    Pintavirooj, Chuchart
    [J]. 2016 9TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2016,
  • [9] Multi-point sensing system for plantar pressure measurement
    Venugopal, G.
    Parmar, Biren J.
    Rajanna, K.
    Nayak, M. M.
    [J]. 2007 IEEE SENSORS, VOLS 1-3, 2007, : 978 - 981
  • [10] Development of a Portable Image-Based Plantar Pressure Measurement System
    Kaewwichit, Thossaporn
    Tseng, Chien-Hsun
    Su, Ke-Han
    Chang, Chong-Ching
    [J]. Journal of the Chinese Society of Mechanical Engineers, Transactions of the Chinese Institute of Engineers, Series C/Chung-Kuo Chi Hsueh Kung Ch'eng Hsuebo Pao, 2021, 42 (02): : 141 - 149