PurposeKnowing the location of the blood vessels supplying the skin and subcutaneous tissue is a requirement during the planning of tissue transfer in reconstructive surgery. Commonly used imaging techniques such as computed tomography angiography and indocyanine green angiography expose the patient to radiation or a contrast agent, respectively. Infrared thermal imaging was evaluated with success as a non-invasive alternative. To support the interpretation of thermograms, a method to automatically detect the perforators was developed and evaluated.MethodsA system consisting of a thermal camera, a PC and custom software was developed. The temperature variations of the skin surface were analysed to extract the perforator locations. A study was conducted to assess the performance of the algorithm by comparing the detection results of the algorithm with manually labelled thermal images by two clinicians of the deep inferior epigastric perforator flap of 20 healthy volunteers.ResultsThe F measure, precision and recall were used to evaluate the system performance. The median F measure is 0.833, the median precision is 0.80, and the median recall is 0.907.ConclusionThe results of this study showed that it is possible to automatically and reliably detect the skin perforators in thermograms despite their weak temperature signature. Infrared thermal imaging is a non-invasive and contactless approach suitable for intraoperative use. Combined with a computer-assisted tool for the automatic detection of perforator vessels, it is a relevant alternative intraoperative imaging method to the standard indocyanine green angiography.
引用
收藏
页码:501 / 507
页数:7
相关论文
共 50 条
  • [1] Automatic detection of perforator vessels using infrared thermography in reconstructive surgery
    Michael Unger
    Miriam Markfort
    Dirk Halama
    Claire Chalopin
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2019, 14 : 501 - 507
  • [2] Automatic detection of subsurface defects using infrared thermography
    Lonkar, GM
    Klinkhachom, P
    Halabe, UB
    GangaRao, HVS
    [J]. REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 24A AND 24B, 2005, 760 : 1469 - 1476
  • [3] Automatic seepage detection in cable tunnels using infrared thermography
    Lu, Zilin
    Zhu, Fulong
    Shi, Lang
    Wang, Fengren
    Zeng, Pengjun
    Hu, Jianxiong
    Liu, Xiaojian
    Xu, Yixin
    Chen, Qian
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (11)
  • [4] The Value of Dynamic Infrared Thermography in Pedicled Thoracodorsal Artery Perforator Flap Surgery
    Sjoberg, Thomas
    Mercer, James B.
    Weum, Sven
    de Weerd, Louis
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2020, 8 (07)
  • [5] AUTOMATIC DEFECT DETECTION IN INFRARED THERMOGRAPHY BY DEEP LEARNING ALGORITHM
    Fang, Qiang
    Nguyen, Ba Diep
    Castanedo, Clemente Ibarra
    Duan, Yuxia
    Maldague, Xavier
    [J]. THERMOSENSE: THERMAL INFRARED APPLICATIONS XLII, 2020, 11409
  • [6] Static Versus Dynamic Infrared Thermography in Perforator Mapping
    de Weerd, Louis
    Mercer, James B.
    Weum, Sven
    [J]. ANNALS OF PLASTIC SURGERY, 2021, 86 (06) : 733 - 734
  • [7] Detection of Dentinal Microcracks Using Infrared Thermography
    Matsushita-Tokugawa, Manami
    Miura, Jiro
    Iwami, Yukiteru
    Sakagami, Takahide
    Izumi, Yui
    Mori, Naoya
    Hayashi, Mikako
    Imazato, Satoshi
    Takeshige, Fumio
    Ebisu, Shigeyuki
    [J]. JOURNAL OF ENDODONTICS, 2013, 39 (01) : 88 - 91
  • [8] Automated thermographic detection of blood vessels for DIEP flap reconstructive surgery
    De La Hoz, Edgar Cardenas
    Verstockt, Jan
    Verspeek, Simon
    Clarys, Warre
    Thiessen, Filip E. F.
    Tondu, Thierry
    Tjalma, Wiebren A. A.
    Steenackers, Gunther
    Vanlanduit, Steve
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2024, 19 (09) : 1733 - 1741
  • [9] Detection of wood damages using infrared thermography
    Pitarma, Rui
    Crisostomo, Joao
    Pereira, Livia
    [J]. 16TH INTERNATIONAL CONFERENCE ON MOBILE SYSTEMS AND PERVASIVE COMPUTING (MOBISPC 2019),THE 14TH INTERNATIONAL CONFERENCE ON FUTURE NETWORKS AND COMMUNICATIONS (FNC-2019),THE 9TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY INFORMATION TECHNOLOGY, 2019, 155 : 480 - 486
  • [10] Automatic detection of diabetic foot complications with infrared thermography by asymmetric analysis
    Liu, Chanjuan
    van Netten, Jaap J.
    van Baal, Jeff G.
    Bus, Sicco A.
    van der Heijden, Ferdi
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (02)