A DSP-based active power filter for low voltage distribution systems

被引:30
|
作者
Shireen, Wajiha [1 ]
Tao, Li [2 ]
机构
[1] Univ Houston, Houston, TX 77204 USA
[2] Schlumberger Inc, Houston, TX USA
关键词
harmonic distortion; active filters; digital signal processors; power quality; power filter; power system harmonics;
D O I
10.1016/j.epsr.2008.01.015
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The use of nonlinear loads, which inject undesired harmonic currents into low voltage distribution systems, is increasing rapidly. Active power filters are being considered as a potential candidate for solving harmonic problems in order to meet harmonic standards and guidelines. A new digital signal processor (DSP)-based control method for a single-phase active power filter (APF) is presented in this paper. Compared to conventional analog-based methods, the DSP-based solution provides a flexible and cheaper method to control the APF The proposed scheme employs a carrier-based control that requires less feedback information compared to other reported solutions. Only one current sensor is used to sense the nonlinear load current and two voltage sensors to sense the input supply voltage and the dc bus voltage. The proposed method provides both harmonic elimination and power factor correction. The PSpice simulation and experiments using the DSIP-based prototype are made to verify the feasibility of the method. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1561 / 1567
页数:7
相关论文
共 50 条
  • [1] A DSP-based active power filter for three-phase power distribution systems
    Wei, Ping
    Zhan, Zhixiong
    Chen, Houquan
    [J]. 2009 INTERNATIONAL CONFERENCE ON COMPUTER ENGINEERING AND TECHNOLOGY, VOL I, PROCEEDINGS, 2009, : 210 - 214
  • [2] DSP-based active power filter with predictive current control
    Jeong, SG
    Woo, MH
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1997, 44 (03) : 329 - 336
  • [3] Three-phrase active power filter based on DSP for power distribution systems
    Wei, Ping
    Chen, Houquan
    Zhan, Zhixiong
    [J]. 2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 3186 - 3190
  • [4] Shunt active power filter - SIMULINK simulation and DSP-based hardware realization
    Yanbo, Che
    Fudan, Zhou
    Cheng, K. W. Eric
    [J]. 2006 2ND INTERNATIONAL CONFERENCE ON POWER ELECTRONICS SYSTEMS AND APPLICATIONS, 2006, : 121 - +
  • [5] DSP-based flexible digital hysteresis in switched capacitor active power filter
    Rahim, Nasrudin Abd.
    Radzi, Mohd Amran Mohd
    [J]. IEICE ELECTRONICS EXPRESS, 2010, 7 (09): : 621 - 627
  • [6] A low-cost DSP-based equipment for the detection of transients in power systems
    Artioli, M
    Pasini, G
    Peretto, L
    Sasdelli, R
    Filippetti, F
    [J]. IMTC/O3: PROCEEDINGS OF THE 20TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1 AND 2, 2003, : 252 - 257
  • [7] A DSP-Based control algorithm for series active filter for optimized compensation under nonsinusoidal and unbalanced voltage conditions
    George, Sincy
    Agarwal, Vivek
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (01) : 302 - 310
  • [8] Control and design issues of a DSP-based shunt active power filter for utility interface of diode rectifiers
    Chen, Z
    Xu, DH
    [J]. APEC 2004: NINETEENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1-3, 2004, : 197 - 203
  • [9] A novel active power filter applied to high voltage distribution systems
    Zhang, CZ
    Chen, QF
    Zhao, YB
    Li, DY
    [J]. ICEMS 2005: PROCEEDINGS OF THE EIGHTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1-3, 2005, : 1791 - 1794
  • [10] DSP-based Direct Power Control of a VSC with voltage angle estimation
    Eloy-Garcia, Joaquin
    Alves, Roberto
    [J]. 2006 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: LATIN AMERICA, VOLS 1-3, 2006, : 639 - +