Construction of 3-D angiography data using the algebraic reconstruction technique (ART)

被引:1
|
作者
Hampton, CJ [1 ]
Hamler, PF [1 ]
机构
[1] Wake Forest Univ, Sch Med, Winston Salem, NC 27109 USA
关键词
three-dimensional reconstruction; algebraic reconstruction technique (ART); 3-D angiography; intraoperative localization and visualization;
D O I
10.1117/12.430990
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Three-dimensional angiographic reconstrcution has emerged as an alternative to the traditional depiction of aneurysm angioarchitecture provided by 2-D perspective project-ions acquired by digital subtraction angiography (DSA) and fluoroscopy. One clinical application of research involving 3-D angiographic reconstruction is intraoperative localization and visualization during aneurysm embolization procedures. For this procedure, reconstruction quality is important for the 3-D reconstruction of anatomy as well as for the reconstrucution of intraaneurysm coils imaged endovascularly and subsequently renderded within an existing 3-D anatomic representation. Rotational angiography involves the acquisition of a series of 2-D, cone-beam projections of intracranial anatomy by a rotating x-ray gantry following a single injection of contrast media. Our investigation focuses on the practicality of using methods that employ algebraic reconstruction techniques (ART) to reconstruct 3-D data from 2-D cone-beam projections acquired using rotational angiography during embolization procedures. Important to our investigation axe issues that arise within the implementation of the projection, correction and backprojection steps of the reconstruction algorithm that affect reconstruction quality. Several methods are discussed to perform accurate voxel grid projection and backprojection. Various parameters of the reconstruction algorithm implementation are also investigated., Preliminary results indicating that quality 3-D reconstructions from 2-D projections of synthetic volumes are presented. Further modifications to our implementation hold the promise of achieving accurate reconstruction results with a lower computation cost than the algorithm implemention used for this study. We have concluded that methods to extend the traditional ART algorithm for cone-beam projection acquisition produce quality 3-D reconstructions.
引用
收藏
页码:98 / 104
页数:3
相关论文
共 50 条
  • [1] Algebraic Reconstruction Technique (ART) using linograms
    Matela, NPL
    Trindade, A
    Martins, MV
    Oliveira, N
    Rodrigues, P
    Peralta, L
    Varela, J
    Almeida, PMD
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S271 - S272
  • [2] The Algebraic Reconstruction Technique (ART)
    Raparia, D
    Alessi, J
    Kponou, A
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS, 1998, : 2023 - 2025
  • [3] Rapid 3-D cone-beam reconstruction with the simultaneous algebraic reconstruction technique (SART) using 2-D texture mapping hardware
    Mueller, K
    Yagel, R
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (12) : 1227 - 1237
  • [4] 3-D model construction using range and image data
    Stamos, I
    Allen, PK
    IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, PROCEEDINGS, VOL I, 2000, : 531 - 536
  • [5] Tomosynthesis reconstruction using the simultaneous algebraic reconstruction technique (SART) on breast phantom data - art. no. 614249
    Zhang, Yiheng
    Chan, Heang-Ping
    Sahiner, Berkman
    Wei, Jun
    Goodsitt, Mitchell M.
    Hadjiiski, Lubomir M.
    Ge, Jun
    Zhou, Chuan
    Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 : 14249 - 14249
  • [6] A fast and accurate projection algorithm for 3D cone-beam reconstruction with the Algebraic Reconstruction Technique (ART)
    Mueller, K
    Yagel, R
    Wheller, JJ
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 724 - 732
  • [7] 3D grainmap generation with the algebraic reconstruction technique from 3DXRD data
    Knudsen, E
    MATERIALS SCIENCE AND TECHNOLOGY, 2005, 21 (12) : 1376 - 1378
  • [8] Detection and 3-D positioning of small defects using 3-D point reconstruction, tracking, and the radiographic magnification technique
    Lindgren, Erik
    NDT & E INTERNATIONAL, 2015, 76 : 1 - 8
  • [9] On the 3-D reconstruction of Coronal Mass Ejections using coronagraph data
    Mierla, M.
    Inhester, B.
    Antunes, A.
    Boursier, Y.
    Byrne, J. P.
    Colaninno, R.
    Davila, J.
    de Koning, C. A.
    Gallagher, P. T.
    Gissot, S.
    Howard, R. A.
    Howard, T. A.
    Kramar, M.
    Lamy, P.
    Liewer, P. C.
    Maloney, S.
    Marque, C.
    McAteer, T. J.
    Moran, T.
    Rodriguez, L.
    Srivastava, N.
    Cyr, O. C. St.
    Stenborg, G.
    Temmer, M.
    Thernisien, A.
    Vourlidas, A.
    West, M. J.
    Wood, B. E.
    Zhukov, A. N.
    ANNALES GEOPHYSICAE, 2010, 28 (01) : 203 - 215
  • [10] 3-D Reconstruction of Bubble Flow Field Based on the Method of Multivision by Rough-Precise Location Algebraic Reconstruction Technique
    Wang, Hong-Yi
    Shi, Ya-Fang
    Zhu, Xin-Jun
    Song, Li-Mei
    Dong, Feng
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71