Percutaneous vertebroplasty with high- versus low-viscosity bone cement for osteoporotic vertebral compression fractures

被引:7
|
作者
Miao, Feng [1 ]
Zeng, Xiaojun [1 ]
Wang, Wei [1 ]
Zhao, Zhou [1 ]
机构
[1] Hubei Univ Med, Renmin Hosp, Dept Spine Surg, 39 Middle Chaoyang Rd, Shiyan 442000, Hubei, Peoples R China
关键词
Percutaneous vertebroplasty; Bone cement; Leakage; Viscosity; Osteoporotic vertebral compression fracture; EMBOLISM; LEAKAGE;
D O I
10.1186/s13018-020-01835-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
ObjectiveThere is no consensus on the best choice between high- and low-viscosity bone cement for percutaneous vertebroplasty (PVP). This study aimed to compare the clinical and radiological outcomes and leakage between three cements with different viscosities in treating osteoporotic vertebral compression fractures.MethodsThis is a prospective study comparing patients who were treated with PVP under local anesthesia: group A (n = 99, 107 vertebrae) with high-viscosity OSTEOPAL V cement, group B (n = 79, 100 vertebrae) with low-viscosity OSTEOPAL V cement, and group C (n = 88, 102 vertebrae) with low-viscosity Eurofix VTP cement. Postoperative pain severity was evaluated using the visual analog scale. Cement leakage was evaluated using radiography and computed tomography.ResultsThere was no significant difference in the incidence of cement leakage between the three groups (group A 20.6%, group B 24.2%, group C 20.6%, P = 0.767). All three groups showed significant reduction in postoperative pain scores but did not differ significantly in pain scores at postoperative 2days (group A 2.01 0.62, group B 2.15 +/- 0.33, group C 1.92 +/- 0.71, P = 0.646). During the 6months after cement implantation, significantly less reduction in the fractured vertebral body height was noticed in group B and group C than in group A (group A 19.0%, group B 8.1%, group C 7.3%, P = 0.009).Conclusions p id=Pa Low-viscosity cement has comparable incidence of leakage compared to high-viscosity cement in PVP for osteoporotic vertebral compression fractures. It also can better prevent postoperative loss of fractured vertebral body's height.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Percutaneous vertebroplasty with high- versus low-viscosity bone cement for osteoporotic vertebral compression fractures
    Feng Miao
    Xiaojun Zeng
    Wei Wang
    Zhou Zhao
    [J]. Journal of Orthopaedic Surgery and Research, 15
  • [2] High- versus low-viscosity cement vertebroplasty and kyphoplasty for osteoporotic vertebral compression fracture: a meta-analysis
    Wang, Qiang
    Sun, Changtai
    Zhang, Liang
    Wang, Lin
    Ji, Quan
    Min, Nan
    Yin, Zilong
    [J]. EUROPEAN SPINE JOURNAL, 2022, 31 (05) : 1122 - 1130
  • [3] High- versus low-viscosity cement vertebroplasty and kyphoplasty for osteoporotic vertebral compression fracture: a meta-analysis
    Qiang Wang
    Changtai Sun
    Liang Zhang
    Lin Wang
    Quan Ji
    Nan Min
    Zilong Yin
    [J]. European Spine Journal, 2022, 31 : 1122 - 1130
  • [4] A comparison of high viscosity bone cement and low viscosity bone cement vertebroplasty for severe osteoporotic vertebral compression fractures
    Zhang, Liang
    Wang, Jingcheng
    Feng, Xinmin
    Tao, Yuping
    Yang, Jiandong
    Wang, Yongxiang
    Zhang, Shengfei
    Cai, Jun
    Huang, Jijun
    [J]. CLINICAL NEUROLOGY AND NEUROSURGERY, 2015, 129 : 10 - 16
  • [5] A comparative study of high-viscosity cement percutaneous vertebroplasty vs. low-viscosity cement percutaneous kyphoplasty for treatment of osteoporotic vertebral compression fractures
    Sun, Kai
    Liu, Yang
    Peng, Hao
    Tan, Jun-feng
    Zhang, Mi
    Zheng, Xian-nian
    Chen, Fang-zhou
    Li, Ming-hui
    [J]. JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2016, 36 (03) : 389 - 394
  • [6] A comparative study of high-viscosity cement percutaneous vertebroplasty vs. low-viscosity cement percutaneous kyphoplasty for treatment of osteoporotic vertebral compression fractures
    Kai Sun
    Yang Liu
    Hao Peng
    Jun-feng Tan
    Mi Zhang
    Xian-nian Zheng
    Fang-zhou Chen
    Ming-hui Li
    [J]. Journal of Huazhong University of Science and Technology [Medical Sciences], 2016, 36 : 389 - 394
  • [7] A Comparative Study of High-viscosity Cement Percutaneous Vertebroplasty vs. Low-viscosity Cement Percutaneous Kyphoplasty for Treatment of Osteoporotic Vertebral Compression Fractures
    孙凯
    刘洋
    彭昊
    谭俊峰
    张觅
    郑先念
    陈方舟
    李明辉
    [J]. Current Medical Science, 2016, (03) : 389 - 394
  • [8] Risk Factors for Cement Leakage in Percutaneous Vertebroplasty for Osteoporotic Vertebral Compression Fractures An Analysis of 1456 Vertebrae Augmented by Low-Viscosity Bone Cement
    Tang, Benqiang
    Cui, Libin
    Chen, Xueming
    Liu, Yadong
    [J]. SPINE, 2021, 46 (04) : 216 - 222
  • [9] A Comparison of Percutaneous Kyphoplasty with High-Viscosity and Low-Viscosity Bone Cement for Treatment of Osteoporotic Vertebral Compression Fractures: A Retrospective Study
    Wang, Wenhao
    Liu, Hao
    Wu, Zhikai
    Teng, Yun
    Huang, Yixue
    Liu, Tao
    Yang, Huilin
    [J]. GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2022, 13
  • [10] High viscosity bone cement vertebroplasty versus low viscosity bone cement vertebroplasty in the treatment of mid-high thoracic vertebral compression fractures
    Luo, An-Jhih
    Liao, Jen-Chung
    Chen, Lih-Hui
    Lai, Po-Liang
    [J]. SPINE JOURNAL, 2022, 22 (04): : 524 - 534