Fully Analog Baseline Wander Elimination Circuit For Real-Time Ambulatory ECG Recording

被引:0
|
作者
Nazari, Masoud [1 ]
Lee, Kye-Shin [1 ]
机构
[1] Univ Akron, Dept ECE, Akron, OH 44325 USA
关键词
Baseline wander elimination; ECG sensor frontend; Linear interpolation; Sampled moving average; Skip sampling;
D O I
10.1109/mwscas.2019.8884992
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work describes a fully analog baseline wander elimination circuit that can be incorporated in the ECG sensor frontend. The proposed approach can effectively remove the baseline wander from ECG signals corrupted with motion artifacts by extracting the baseline level, and subtracting it from the original ECG signal in the analog domain. The baseline level is detected by linearly interpolating the sampled moving average values of the corrupted signal within a certain period. In this case, in order to exclude huge R-peak samples from the moving average, a skip sampling technique is adopted. The proposed circuit is realized with 0.18-mu m CMOS technology using 1.8 V supply voltage. Results show SNR improvement of 26.7 dB after eliminating baseline wander from a corrupted ECG waveform with power consumption of 11.8 mu W.
引用
收藏
页码:33 / 36
页数:4
相关论文
共 50 条
  • [1] Low-Power Real-Time ECG Baseline Wander Removal: Hardware Implementation
    Guven, Onur
    Eftekhar, Amir
    Kindt, Wilko
    Constandinou, Timothy G.
    [J]. 2017 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2017,
  • [2] ECG Baseline Wander Elimination using Wavelet Packets
    Mozaffary, Behzad
    Tinati, Mohammad A.
    [J]. PROCEEDINGS OF WORLD ACADEMY OF SCIENCE, ENGINEERING AND TECHNOLOGY, VOL 3, 2005, 3 : 14 - 16
  • [3] REAL-TIME FETAL ECG RECORDING
    BERGVELD, P
    KOLLING, AJ
    PEUSCHER, JHJ
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (05) : 505 - 509
  • [4] Real-Time Baseline Wander Removal in ECG Signal Based on Weighted Local Linear Regression Smoothing
    Tan, Xiao
    Chen, Xianxiang
    Ren, Ren
    Hu, Xinyu
    Zhou, Bing
    Fang, Zhen
    Xia, Shanhong
    [J]. 2013 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION (ICIA), 2013, : 453 - 456
  • [5] Real-Time Baseline Wander Removal from Electrooculography Using Probabilistic Baseline Prediction
    Baek, Changhoon
    Goo, Yongsook
    Seo, Jong-Mo
    [J]. 6TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2015, 45 : 78 - +
  • [6] PORTABLE DEVICE FOR REAL-TIME ECG RECORDING AND TELEMETRY
    Naeemabadi, Mohammad Reza
    Chomachar, Nooshaz Amirahmadi
    Khalilzadeh, Mohammad Ali
    Dehnavi, Alireza Mehri
    [J]. 2011 24TH CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (CCECE), 2011, : 508 - 511
  • [7] An 8-Channel Ambulatory EEG Recording IC With In-Channel Fully-Analog Real-Time Motion Artifact Extraction and Removal
    Dabbaghian, Alireza
    Kassiri, Hossein
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2023, 17 (05) : 999 - 1009
  • [8] A New Strategy for ECG Baseline Wander Elimination Using Empirical Mode Decomposition
    Shahbakhti, Mohammad
    Bagheri, Hamed
    Shekarchi, Babak
    Mohammadi, Somayeh
    Naji, Mohsen
    [J]. FLUCTUATION AND NOISE LETTERS, 2016, 15 (02):
  • [9] LOW-COST ADAPTIVE METHOD FOR REAL-TIME ECG BASELINE WANDER REMOVAL WITH REDUCED P AND T WAVE DISTORTION
    Fraile, Ruben
    Ignacio Godino-Llorente, Juan
    [J]. BIOSIGNALS 2009: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIO-INSPIRED SYSTEMS AND SIGNAL PROCESSING, 2009, : 476 - 479
  • [10] Real-Time Estimation of the ECG-Derived Respiration (EDR) Signal using a New Algorithm for Baseline Wander Noise Removal
    Arunachalam, Shivaram P.
    Brown, Lewis F.
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5681 - +