A compact light shield for the Psyche gamma-ray spectrometer

被引:1
|
作者
Hines, Nathan R. [1 ,2 ]
Burks, Morgan T. [1 ]
Kim, Geon-Bo [1 ]
Lawrence, David J. [3 ]
McNeil, Walter J. [2 ]
机构
[1] Lawrence Livermore Natl Lab, 7000 East Ave, Livermore, CA 94550 USA
[2] Kansas State Univ, 1200 N MLK Jr Dr, Manhattan, KS 66506 USA
[3] Johns Hopkins Univ, Appl Phys Lab, 11100 Johns Hopkins Rd, Laurel, MD 20723 USA
关键词
HPGe; Gamma-ray; Spectroscopy; Leakage current; Vacuum; (16) Psyche;
D O I
10.1016/j.nima.2022.167491
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A compact, low-mass light shield has been designed for the Psyche space mission high-purity germanium gamma-ray spectrometer. The spectrometer will be vented to space, which can allow solar photons to enter the cryostat and cause charge-induced noise. The light shield was designed to block more than 99.9% of solar photons while maintaining high molecular conductance to space vacuum. COMSOL simulations and experiments were performed to characterize light shield photon attenuation and molecular conductance. The light shield was integrated onto the gamma-ray spectrometer and photon suppression and vacuum performance were demonstrated.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] FAST TIMED ACTIVE SHIELD FOR A GAMMA-RAY SPECTROMETER
    Todorovic, Natasa
    Mrda, Dusan
    Bikit, Istvan
    Forkapic, Sofija
    Slivka, Jaroslav
    Veskovic, Miroslav
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 130 - 135
  • [2] BISMUTH GERMANATE GAMMA-RAY SPECTROMETER WITH A PLASTIC ANTICOINCIDENCE SHIELD.
    Wagenaar, Douglas J.
    Roberson, N.R.
    Weller, H.R.
    Tilley, D.R.
    Nuclear instruments and methods in physics research, 1985, A234 (01): : 109 - 115
  • [3] A BISMUTH-GERMANATE GAMMA-RAY SPECTROMETER WITH A PLASTIC ANTICOINCIDENCE SHIELD
    WAGENAAR, DJ
    ROBERSON, NR
    WELLER, HR
    TILLEY, DR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 234 (01): : 109 - 115
  • [4] A compact gamma-ray spectrometer for nuclear astrophysics and planetary science
    Hughes, Zachary
    Errando, Manel
    Olbemo, Tekeba
    Ho, William
    SPACE TELESCOPES AND INSTRUMENTATION 2022: ULTRAVIOLET TO GAMMA RAY, 2022, 12181
  • [5] Gamma-ray observations with the Transient Gamma-Ray Spectrometer (TGRS)
    Seifert, H
    Teegarden, BJ
    Cline, TL
    Gehrels, N
    Hurley, KH
    Madden, N
    Owens, A
    Palmer, DM
    Pehl, R
    Ramaty, R
    ASTRONOMY & ASTROPHYSICS SUPPLEMENT SERIES, 1996, 120 (04): : C653 - C656
  • [6] GAMMA-RAY LINE INVESTIGATIONS WITH THE DURHAM GAMMA-RAY SPECTROMETER
    AYRE, CA
    BHAT, PN
    OWENS, A
    SUMMERS, WM
    THOMPSON, MG
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1981, 301 (1462): : 687 - 691
  • [7] SILICON GAMMA-RAY SPECTROMETER
    GIBBONS, PE
    NORTHROP, DC
    NATURE, 1960, 188 (4753) : 803 - 803
  • [8] THE TRANSIENT GAMMA-RAY SPECTROMETER
    OWENS, A
    BAKER, R
    CLINE, TL
    GEHRELS, N
    JERMAKIAN, J
    NOLAN, T
    RAMATY, R
    SMITH, G
    STILWELL, DE
    TEEGARDEN, BJ
    TROMBKA, J
    YAVER, H
    CORK, CP
    LANDIS, DA
    LUKE, PN
    MADDEN, NW
    MALONE, D
    PEHL, RH
    HURLEY, K
    MATHIAS, S
    POST, AH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 559 - 567
  • [9] RANGER GAMMA-RAY SPECTROMETER
    METZGER, AE
    ANDERSON, EC
    VANDILLA, MA
    ARNOLD, JR
    NUCLEONICS, 1962, 20 (10): : 64 - +
  • [10] STABILISATION OF A GAMMA-RAY SPECTROMETER
    DIXON, I
    NUCLEAR INSTRUMENTS & METHODS, 1963, 25 (01): : 26 - 28