Sampling systems for isotope-ratio mass spectrometry of atmospheric ammonia

被引:12
|
作者
Skinner, R [1 ]
Ineson, P
Jones, H
Sleep, D
Theobald, M
机构
[1] Univ York, York YO10 5DD, N Yorkshire, England
[2] CEH Lancaster, Lancaster LA1 4AP, England
[3] CEH Edinburgh, Penicuik EH26 0QB, Midlothian, Scotland
基金
英国自然环境研究理事会;
关键词
D O I
10.1002/rcm.2279
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Passive and active ammonia (NH3) sampling devices have been tested for their nitrogen (N) capture potential and delta N-15 fractionation effects. Several sampling techniques produced significantly different delta(15) NH3 signals when sampling the same NH3 source released from field site fumigation campaigns. Conventional passive NH3-Monitoring systems have shown to provide insufficient N for isotope-ratio mass spectrometry and various modified devices have been developed, based on existing diffusion tube designs, to overcome this problem. The final sampler design was then tested in a wind tunnel to verify that sampling NH3 in different environmental conditions did not significantly fractionate the delta N-15 signal. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 50 条
  • [1] ISOTOPE-RATIO AND BACKGROUND CORRECTIONS FOR ACCELERATOR MASS-SPECTROMETRY RADIOCARBON MEASUREMENTS
    DONAHUE, DJ
    LINICK, TW
    JULL, AJT
    RADIOCARBON, 1990, 32 (02) : 135 - 142
  • [2] Determination of surfactant bio-sourced origin by isotope-ratio mass spectrometry
    Gaubert, Alexandra
    Jame, Patrick
    Bordes, Claire
    Clement, Yohann
    Guibert, Sylvie
    Batteau, Magali
    Lomberget, Thierry
    Anchisi, Anthony
    Lanteri, Pierre
    Casabianca, Herve
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2016, 30 (09) : 1108 - 1114
  • [3] NITROGEN GAS PREPARATIVE SYSTEM FOR ISOTOPE-RATIO ANALYSIS BY MASS-SPECTROMETRY
    SMITH, CJ
    CHALK, PM
    ANALYTICA CHIMICA ACTA, 1979, 104 (02) : 245 - 252
  • [4] Comparison of catabolic rates of fatty acids using stable isotope and isotope-ratio mass spectrometry
    Gotoh, Naohiro
    Nagai, Toshiharu
    Yoshinaga, Kazuaki
    Mizobe, Hoyo
    Watanabe, Hiroyuki
    Lipid Technology, 2013, 25 (05) : 110 - 112
  • [5] A MICROPROCESSOR-CONTROLLED DEVICE FOR ISOTOPE-RATIO MEASUREMENTS BY MASS-SPECTROMETRY
    BANCROFT, PG
    CHALK, PM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 275 (01): : 192 - 193
  • [6] Protein Stable Isotope Fingerprinting: Multidimensional Protein Chromatography Coupled to Stable Isotope-Ratio Mass Spectrometry
    Mohr, Wiebke
    Tang, Tiantian
    Sattin, Sarah R.
    Bovee, Roderick J.
    Pearson, Ann
    ANALYTICAL CHEMISTRY, 2014, 86 (17) : 8514 - 8520
  • [7] Caution on the Use of Liquid Nitrogen Traps in Stable Hydrogen Isotope-Ratio Mass Spectrometry
    Coplen, Tyler B.
    Qi, Haiping
    ANALYTICAL CHEMISTRY, 2010, 82 (18) : 7849 - 7851
  • [8] Invited Review Article: Recent developments in isotope-ratio mass spectrometry for geochemistry and cosmochemistry
    Ireland, Trevor R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (01):
  • [9] GAS-CHROMATOGRAPHY WITH MASS-SPECTROMETRY OR ISOTOPE-RATIO MASS-SPECTROMETRY IN STUDYING THE GEOGRAPHICAL ORIGIN OF HEROIN
    DESAGE, M
    GUILLUY, R
    BRAZIER, JL
    CHAUDRON, H
    GIRARD, J
    CHERPIN, H
    JUMEAU, J
    ANALYTICA CHIMICA ACTA, 1991, 247 (02) : 249 - 254
  • [10] Accuracy of δ18O isotope ratio measurements on the same sample by continuous-flow isotope-ratio mass spectrometry
    Wong, William W.
    Clarke, Lucinda L.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2015, 29 (23) : 2252 - 2256