Splitting strength of hybrid fiber reinforced Concrete after exposure to elevated temperatures

被引:3
|
作者
Li, Han [1 ]
Gao, Danying [1 ]
机构
[1] Zhengzhou Univ, Res Ctr New Style Bldg Mat & Struct, Zhengzhou 450002, Peoples R China
关键词
steel fiber; polypropylene fiber; high temperature; splitting strength; POLYPROPYLENE FIBERS; RESIDUAL STRENGTH; RESISTANCE;
D O I
10.4028/www.scientific.net/AMM.71-78.1695
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Experiments were carried out to investigate the splitting properties of hybrid fiber reinforced concrete after exposure to elevated temperatures. Based on the experimental observation, the effect of steel fiber dosage, polypropylene (PP) fiber dosage and strength grade of concrete on the residual splitting strength of the concrete after being subjected to high temperature was systematically analyzed. Test data indicated that high temperature caused significant deterioration in the splitting strength of concrete; the addition of PP fiber and steel fiber could all effectively improve the residual splitting properties of concrete; the optimum amount of PP fiber and steel fiber were identified respectively; the degree of strength loss of concrete with different strength grades was very close to each other. A theoretical equation was proposed to predict the residual splitting strength of concrete after being heated to temperatures up to 800 degrees C.
引用
收藏
页码:1695 / 1702
页数:8