Pre-operative assessment of living renal transplant donors with state-of-the-art imaging modalities: computed tomography angiography versus magnetic resonance angiography in 118 patients

被引:16
|
作者
Engelken, F. [1 ]
Friedersdorff, F. [2 ]
Fuller, T. F. [2 ]
Magheli, A. [2 ]
Budde, K. [3 ]
Halleck, F. [3 ]
Deger, S. [5 ]
Liefeldt, L. [3 ]
Hamm, B. [1 ]
Giessing, M. [4 ]
Diederichs, G. [1 ]
机构
[1] Charite, Dept Radiol, D-10117 Berlin, Germany
[2] Charite, Dept Urol, D-10117 Berlin, Germany
[3] Charite, Dept Nephrol, D-10117 Berlin, Germany
[4] Univ Dusseldorf, Dept Urol, D-40225 Dusseldorf, Germany
[5] Paracelsus Krankenhaus Ruit, Dept Urol, Ostfildern, Germany
关键词
Renal transplantation; Vascular anatomy; Living renal donors; CT angiography; MR angiography; MULTIDETECTOR-ROW CT; KIDNEY DONORS; MR-ANGIOGRAPHY; URETERAL COMPLICATIONS; VASCULAR ANATOMY; NEPHRECTOMY; MULTIPLE; ARTERIES; EXPERIENCE; RECIPIENT;
D O I
10.1007/s00345-012-1022-y
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
To compare current technology multislice computed tomography angiography (CTA) with magnetic resonance angiography (MRA) in the pre-operative evaluation of vascular anatomy of living renal transplant donors. Two hundred and thirty-six kidneys were included in the CTA and MRA analysis. Renal vasculature was evaluated independently by two readers in each modality with a delay of 4 weeks between reading sessions. Surgical correlation on the operated side was available in all patients. The reference standard was defined by surgical correlation and consensus reading of both modalities. Detection rate of CTA for arteries was 99.1 and 95.0 % for reader 1 and reader 2, respectively. Detection rate of MRA for arteries was 95.0/94.3 %. Most of the undetected arteries were a parts per thousand currency sign1 mm diameter (reader 1: 2 of 3 in CTA and 9 of 16 in MRA; reader 2: 11 of 16 in CTA, and 8 of 18 in MRA). Detection rates for arteries a parts per thousand yen2 mm for reader 1/reader 2 were 99.7/98.7 % in CTA and 99.1/97.8 % in MRA, respectively. Detection rates for veins were 99.6/97.4 % in CTA and 97.8/96.9 % in MRA, respectively. Both readers misdiagnosed between 0 and 1 non-present arteries and between 2 and 3 non-present veins in both modalities. Modern multislice CT and MRI scanners allow highly accurate evaluation of the vascular anatomy, especially for vessels of a parts per thousand yen2 mm diameter. CTA may provide slightly better depiction of very small arteries; however, this may be reader-dependent. Additional factors affecting the choice of imaging modality should include local availability, cost, and the desire to avoid ionizing radiation in healthy transplant donors.
引用
收藏
页码:983 / 990
页数:8
相关论文
共 50 条
  • [1] Pre-operative assessment of living renal transplant donors with state-of-the-art imaging modalities: computed tomography angiography versus magnetic resonance angiography in 118 patients
    F. Engelken
    F. Friedersdorff
    T. F. Fuller
    A. Magheli
    K. Budde
    F. Halleck
    S. Deger
    L. Liefeldt
    B. Hamm
    M. Giessing
    G. Diederichs
    World Journal of Urology, 2013, 31 : 983 - 990
  • [2] Pre-operative assessment of living renal transplant donors with state-of-the-art imaging modalities: Computed tomography angiography vs. magnetic resonance angiography in 118 patients
    Friedersdorff, F.
    Engelken, F.
    Hamm, B.
    Fuller, T. F.
    Deger, S.
    Magheli, A.
    Budde, K.
    Miller, K.
    Diederichs, G.
    EUROPEAN UROLOGY SUPPLEMENTS, 2012, 11 (01) : E316 - E316
  • [3] Pre-Operative Assessment of Living Renal Transplant Donors with State-Of-The-Art Imaging Modalities: Computed Tomography Angiography vs. Magnetic Resonance Angiography in 118 Patients
    Friedersdorff, F.
    Engelken, F.
    Hamm, B.
    Fuller, F.
    Deger, S.
    Magheli, A.
    Budde, K.
    Diederichs, G.
    TRANSPLANTATION, 2012, 94 (10) : 187 - 187
  • [4] Renal imaging: duplex ultrasound, computed tomography angiography, magnetic resonance angiography, and angiography
    AbuRahma, Ali F.
    Yacoub, Michael
    SEMINARS IN VASCULAR SURGERY, 2013, 26 (04) : 134 - 143
  • [5] Evaluation of MR-angiography for pre-operative assessment of living kidney donors
    Prosst, RL
    Fernández, ED
    Neff, W
    Braun, C
    Neufang, T
    Post, S
    CLINICAL TRANSPLANTATION, 2005, 19 (04) : 522 - 526
  • [6] Noncontrast-Enhanced Magnetic Resonance Versus Computed Tomography Angiography in Preoperative Evaluation of Potential Living Renal Donors
    Blankholm, Anne Dorte
    Pedersen, Bodil G.
    Ostrat, Ernst O.
    Andersen, Gratien
    Stausbol-Gron, Brian
    Laustsen, Susse
    Ringgaard, Steffen
    ACADEMIC RADIOLOGY, 2015, 22 (11) : 1368 - 1375
  • [7] Value of cardiac computed tomography angiography in pre-operative assessment of infective endocarditis
    Narumol Chaosuwannakit
    Pattarapong Makarawate
    Journal of Cardiothoracic Surgery, 14
  • [8] Value of cardiac computed tomography angiography in pre-operative assessment of infective endocarditis
    Chaosuwannakit, Narumol
    Makarawate, Pattarapong
    JOURNAL OF CARDIOTHORACIC SURGERY, 2019, 14 (1)
  • [9] High resolution computed tomography and magnetic resonance imaging in the pre-operative assessment of cochlear implant patients
    Gleeson, TG
    Lacy, PD
    Bresnihan, M
    Gaffney, R
    Brennan, P
    Viani, L
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2003, 117 (09): : 692 - 695
  • [10] Non-invasive imaging of living kidney donors: intraindividual comparison of multislice computed tomography angiography with magnetic resonance angiography
    Liefeldt, Lutz
    Kluener, Claudia
    Glander, Petra
    Giessing, Markus
    Budde, Klemens
    Taupitz, Matthias
    Rogalla, Patrik
    Kroencke, Thomas J.
    CLINICAL TRANSPLANTATION, 2012, 26 (04) : E412 - E417