Reproducibility of human cardiac phosphorus MRS (31P-MRS) at 7 T

被引:18
|
作者
Ellis, Jane [1 ]
Valkovic, Ladislav [1 ,2 ]
Purvis, Lucian A. B. [1 ]
Clarke, William T. [1 ,3 ]
Rodgers, Christopher T. [1 ,4 ]
机构
[1] Univ Oxford, RDM Cardiovasc Med, OCMR, Oxford, England
[2] Slovak Acad Sci, Inst Measurement Sci, Bratislava, Slovakia
[3] Univ Oxford, Nuffield Dept Clin Neurosci, FMRIB, Wellcome Ctr Integrat Neuroimaging, Oxford, England
[4] Univ Cambridge, Dept Clin Neurosci, Wolfson Brain Imaging Ctr, Cambridge, England
基金
英国惠康基金; 英国医学研究理事会;
关键词
P-31; 7; T; cardiac; human; MRS; reproducibility; MAGNETIC-RESONANCE-SPECTROSCOPY; ENERGY PHOSPHATE METABOLITES; CORONARY-ARTERY-DISEASE; DILATED CARDIOMYOPATHY; IN-VIVO; HEART; QUANTIFICATION; MYOCARDIUM;
D O I
10.1002/nbm.4095
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Purpose We test the reproducibility of human cardiac phosphorus MRS (P-31-MRS) at ultra-high field strength (7 T) for the first time. The primary motivation of this work was to assess the reproducibility of a 'rapid' 61/2 min P-31 three-dimensional chemical shift imaging (3D-CSI) sequence, which if sufficiently reproducible would allow the study of stress-response processes. We compare this with an established 28 min protocol, designed to record high-quality spectra in a clinically feasible scan time. Finally, we use this opportunity to compare the effect of per-subject B-0 shimming on data quality and reproducibility in the 61/2 min protocol. Methods 10 healthy subjects were scanned on two occasions: one to test the 28 min 3D-CSI protocol, and one to test the 61/2 min protocol. Spectra were fitted using the OXSA MATLAB toolbox. The phosphocreatine to adenosine triphosphate concentration ratio (PCr/ATP) from each scan was analysed for intra- and intersubject variability. The impact of different strategies for voxel selection was assessed. Results There were no significant differences between repeated measurements in the same subject. For the 28 min protocol, PCr/ATP in the midseptal voxel across all scans was 1.91 +/- 0.36 (mean +/- intersubject SD). For the 61/2 min protocol, PCr/ATP in the midseptal voxel was 1.76 +/- 0.40. The coefficients of reproducibility (CRs) were 0.49 (28 min) and 0.67 (61/2 min). Per-subject B-0 shimming improved the fitted PCr/ATP precision (for 61/2 min scans), but had negligible effect on the CR (0.67 versus 0.66). Conclusions Both 7 T protocols show improved reproducibility compared with a previous 3 T study by Tyler et al. Our results will enable informed power calculations and protocol selection for future clinical research studies.
引用
下载
收藏
页数:11
相关论文
共 50 条
  • [1] Concentration of human cardiac 31P-metabolites determined by SLOOP 31P-MRS
    Landschuetz, W.
    Meininger, M.
    Beer, M.
    Seyfarth, T.
    Horn, M.
    Pabst, T.
    Haase, A.
    Hahn, D.
    Neubauer, S.
    von Kienlin, M.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1998, 6 (2-3) : 155 - 156
  • [2] 31P-MRS of healthy human brain: Measurement of guanosine diphosphate mannose at 7 T
    Ren, Jimin
    Sherry, A. Dean
    NMR IN BIOMEDICINE, 2021, 34 (10)
  • [3] Depth-resolved surface coil MRS (DRESS)-localized dynamic 31P-MRS of the exercising human gastrocnemius muscle at 7 T
    Valkovic, Ladislav
    Chmelik, Marek
    Kukurova, Ivica Just
    Jakubova, Michaela
    Kipfelsberger, Monika Christina
    Krumpolec, Patrik
    Jelenc, Marjeta Tusek
    Bogner, Wolfgang
    Meyerspeer, Martin
    Ukropec, Jozef
    Frollo, Ivan
    Ukropcova, Barbara
    Trattnig, Siegfried
    Krssak, Martin
    NMR IN BIOMEDICINE, 2014, 27 (11) : 1346 - 1352
  • [4] Detection of monoester signals in human myocardium by 31P-MRS
    Widmaier, Stefan
    Jung, Wulf-Ingo
    Sieverding, Ludger
    Breuer, Johannes
    Schmidt, Oliver
    Dietze, Gunther J.
    Lutz, Otto
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 1998, 6 (2-3) : 161 - 163
  • [5] Bloch-Siegert B1+-Mapping for Human Cardiac 31P-MRS at 7 Tesla
    Clarke, William T.
    Robson, Matthew D.
    Rodgers, Christopher T.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (04) : 1047 - 1058
  • [6] 31P-MRS of the healthy human brain at 7 T detects multiple hexose derivatives of uridine diphosphate glucose
    Ren, Jimin
    Malloy, Craig R.
    Sherry, A. Dean
    NMR IN BIOMEDICINE, 2021, 34 (07)
  • [7] 31P-MRS in Migraine: Fallen Through the Cracks
    Paemeleire, Koen
    Schoenen, Jean
    HEADACHE, 2013, 53 (04): : 676 - 678
  • [8] Effects of hyperthermia on bioenergetic status and phosphorus T1S in human melanoma xenografts monitored by 31P-MRS
    Olsen, DR
    Singstad, TE
    Rofstad, EK
    MAGNETIC RESONANCE IMAGING, 1999, 17 (07) : 1049 - 1056
  • [9] Insights into neuromuscular fatigue using 31P-MRS
    Forbes, Sean C.
    JOURNAL OF PHYSIOLOGY-LONDON, 2022, 600 (13): : 3011 - 3012
  • [10] Reproducibility Assessment of Metabolic Variables Characterizing Muscle Energetics In Vivo: A 31P-MRS Study
    Layec, Gwenael
    Bringard, Aurelien
    Le Fur, Yann
    Vilmen, Christophe
    Micallef, Jean-Paul
    Perrey, Stephane
    Cozzone, Patrick J.
    Bendahan, David
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (04) : 840 - 854