Influence of Spectral Characteristics on the Accuracy of Concentration Quantitatively Analysis by NIR

被引:1
|
作者
Zhao Zhe [1 ,2 ,3 ]
Wang Hui [1 ]
Wang Hui-quan [1 ,2 ,3 ]
He Xin-wei [1 ]
Miao Jing-hong [1 ,2 ]
Wang Jin-hai [1 ,2 ]
机构
[1] Tianjin Polytech Univ, Sch Elect & Informat Engn, Tianjin 300387, Peoples R China
[2] Tianjin Key Lab Optoelect Detect Technol & Syst, Tianjin 300387, Peoples R China
[3] Tianjin Univ, Sch Precis Instrument & Optoelect Engn, Tianjin 300072, Peoples R China
关键词
Overlapping coefficient; Noise-signal ratio; Spectrum analysis; Measurable analysis;
D O I
10.3964/j.issn.1000-0593(2019)04-1070-05
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In order to solve the problem of measurement blindness caused by the lack of measurable analysis in the the near-infrared spectroscopy, we can roughly estimate the analytical error of the concentration of the tested substances using the spectral characteristics of near-infrared spectroscopy under the known conditions of measurement, sample types, components under analysis and modeling and analysis methods, before a large number of samples were collected by near-infrared spectroscopy and concentration data measured by standard method. In the research, two important parameters, ESNR and OC, were proposed and tested. ESNR reflects the proportion of the component absorbance to the total absorbance, while OC reflects the overlap degree between near-infrared spectral curves of the components. We got the relationship between spectral characteristics and concentration analysis error when using the classical partial least squares regression in spectral analysis to establish quantitative analysis model through theoretical simulation. The relationship between ESNR and OC and the concentration of analyte (RMSE) was calculated respectively, and the independence of the two spectral parameters was also studied. The results of theoretical analysis were used to measure the concentration of aqueous ethanol solution between 8% and 12%, and compared with the actual results of near infrared spectroscopy. The relationship between the spectra] characteristics and the concentration analysis errors when using partial least squares regression to establish a quantitative analysis model was obtained through theoretical simulation. ESNR is inversely proportional to RMSE, and OC is in a non-linear monotonic relationship with the measured component analysis error, and the independence of ESNR and OC was verified. The quantitative relationship between ESNR and OC and spectral concentration error was discussed by theoretical calculations and near-infrared spectroscopy of ethanol aqueous solution. The RMSE of ethanol concentration was 0. 3% which was estimated by theoretical analysis, and the RMSE of near infrared spectroscopy was 0. 32%. The relative error was 6. 67%. We have realized the quantitative calculation and experimental verification of the theoretical error of the content of the tested components based on near infrared spectroscopy under the conditions of the measurement conditions, the types of samples, the components to be measured, and the methods of modeling and analysis. This study identified two spectral parameters that have a clear and quantitative relationship with the concentration of the measured component in NIR spectroscopy. The analytical accuracy empirical curve was established when using the classical partial least-squares regression in spectral analysis. In addition, the analysis of the measurable degree of the concentration of the components could also be tested by near infrared spectroscopy. The results showed the effectiveness of the ESNR and OC in this paper, as well as the analytical method of error prediction. This study provided an effective and rapid prediction method for the quantitative analysis of near infrared spectroscopy, and optimized the theory of measurable analysis of near infrared spectroscopy, which has a good guidance for the quantitative analysis of the concentration of near infrared spectroscopy.
引用
收藏
页码:1070 / 1074
页数:5
相关论文
共 15 条
  • [1] Camara A B F, 2017, FUEL
  • [2] Chen HongYan Chen HongYan, 2014, Transactions of the Chinese Society of Agricultural Engineering, V30, P91
  • [3] A systematic study on the application of scatter-corrective and spectral-derivative preprocessing for multivariate prediction of soil organic carbon by Vis-NIR spectra
    Dotto, Andre Carnieletto
    Diniz Dalmolin, Ricardo Simao
    ten Caten, Alexandre
    Grunwald, Sabine
    [J]. GEODERMA, 2018, 314 : 262 - 274
  • [4] Two preprocessing techniques to reduce model covariables in soil property predictions by Vis-NIR spectroscopy
    Dotto, Andre Carnieletto
    Diniz Dalmolin, Ricardo Simao
    Grunwald, Sabine
    ten Caten, Alexandre
    Pereira Filho, Waterloo
    [J]. SOIL & TILLAGE RESEARCH, 2017, 172 : 59 - 68
  • [5] FAN Rui, 2017, Modern Food Science and Technology, V33, P264
  • [6] The relationship between the perfusion index and precision of noninvasive blood component measurement based on dynamic spectroscopy
    Feng, Ximeng
    Yu, Haixia
    Yi, Xiaoqing
    Wang, Shaohui
    Li, Gang
    Lin, Ling
    [J]. ANALYTICAL METHODS, 2017, 9 (17) : 2578 - 2584
  • [7] Association between Elevated Hemoglobin A1c Levels and the Outcomes of Patients with Small-Artery Occlusion: A Hospital-Based Study
    Gao, Yuan
    Jiang, Lihong
    Wang, Hui
    Yu, Changshen
    Wang, Wanjun
    Liu, Shoufeng
    Gao, Chunlin
    Tong, Xiaoguang
    Wang, Jinhuan
    Jin, Yi
    Wu, Jialing
    [J]. PLOS ONE, 2016, 11 (08):
  • [8] Floating reference position-based correction method for near-infrared spectroscopy in long-term glucose concentration monitoring
    Han, Guang
    Han, Tongshuai
    Xu, Kexin
    Liu, Jin
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (07)
  • [9] Holland JK, 1998, J SCI FOOD AGR, V76, P263, DOI 10.1002/(SICI)1097-0010(199802)76:2<263::AID-JSFA943>3.0.CO
  • [10] 2-F