An evaluation of intraoperative digital specimen mammography versus conventional specimen radiography for the excision of nonpalpable breast lesions

被引:28
|
作者
Kim, Song Hon H. [1 ,2 ]
Cornacchi, Sylvie D. [1 ,2 ]
Heller, Barbara [1 ,2 ]
Farrokhyar, Forough [1 ,2 ,3 ]
Babra, Melissa [1 ,2 ]
Lovrics, Peter J. [1 ,2 ]
机构
[1] McMaster Univ, Dept Surg, Hamilton, ON L8N 4A6, Canada
[2] St Josephs Healthcare, Hamilton, ON L8N 4A6, Canada
[3] McMaster Univ, Dept Clin Epidemiol & Biostat, Hamilton, ON L8N 4A6, Canada
来源
AMERICAN JOURNAL OF SURGERY | 2013年 / 205卷 / 06期
关键词
Breast cancer; Wire localization; Breast conservation surgery; Positive margin status; Faxitron microradiography; Specimen mammography; SURGICAL MARGIN STATUS; 20-YEAR FOLLOW-UP; CONSERVING SURGERY; CONSERVATION THERAPY; RE-EXCISION; PARTIAL MASTECTOMY; GROSS EXAMINATION; CANCER PATIENTS; SHAVED MARGINS; LUMPECTOMY;
D O I
10.1016/j.amjsurg.2012.08.010
中图分类号
R61 [外科手术学];
学科分类号
摘要
BACKGROUND: This study examined the impact of intraoperative digital specimen mammography (IDSM) compared with conventional specimen radiography (CSR) for nonpalpable breast lesions in patients undergoing breast-conserving surgery (BCS). METHODS: In this retrospective cohort study, 201 consecutive image-detected nonpalpable breast lesions underwent BCS after preoperative localization and specimen radiography. Data on patient, tumor, and surgical factors were collected. RESULTS: CSR was performed in 105 patients and IDSM was used in 96 patients. Patient and tumor factors were similar in both groups. Using univariate analysis, CSR resulted in more positive margins (19% vs 6.2%; P = .012). Rates of cavity margin resection, reoperation, and operative times were similar for CSR and IDSM. Independent predictors of positive margins on multivariable analysis were use of CSR, microcalcifications on mammography, the need for bracketing for localization, and no cavity margin excision (all P < .05). CONCLUSIONS: In this study, the use of IDSM resulted in fewer positive margins after BCS, although operative times were similar. (c) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:703 / 710
页数:8
相关论文
共 50 条
  • [1] Intraoperative digital specimen radiography in the treatment of nonpalpable breast lesions
    Vicko, Ferenc
    Radovanovic, Zoran
    Ivkovic-Kapicl, Tatjana
    Dilas, Dragana
    Lukic, Dejan
    Tatic, Milanka
    Petrovic, Tatjana
    [J]. SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2017, 145 (7-8) : 378 - 381
  • [2] Intraoperative Specimen Radiography in Patients with Nonpalpable Malignant Breast Lesions
    Schmachtenberg, C.
    Engelken, F.
    Fischer, T.
    Bick, U.
    Poellinger, A.
    Fallenberg, E. M.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (07): : 635 - 642
  • [3] SPECIMEN RADIOGRAPHY FOR NONPALPABLE BREAST LESIONS FOUND BY MAMMOGRAPHY - PROCEDURES AND RESULTS
    ROSEN, PP
    SNYDER, RE
    ROBBINS, G
    [J]. CANCER, 1974, 34 (06) : 2028 - 2033
  • [4] A Comparison of Intraoperative Versus Traditional Specimen Radiography in Patients Undergoing Breast-Conserving Surgery for Nonpalpable Breast Lesions
    Goodwin, Mary Catherine
    Stull, Tari S.
    Collett, Abigail E.
    Chernick, Michael R.
    Barrio, Andrea V.
    Frazier, Thomas G.
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2011, 18 : S168 - S168
  • [5] Intraoperative Specimen Tomosynthesis Comparison With Digital Specimen Mammography
    Kaufman, Cary S.
    Behrndt, Valerie
    Hill, Laurie
    Caro, Rebecca
    Nix, Sid
    Evans, Erik
    Schnell, Nancy
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2015, 22 : 66 - 66
  • [6] SPECIMEN RADIOGRAPHY IN SELECTIVE RECOGNITION OF BREAST LESIONS SUSPECTED ON MAMMOGRAPHY
    MENGES, V
    ENGELER, V
    STADELMANN, R
    [J]. DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1974, 99 (20) : 1058 - +
  • [7] Clinical Evaluation of a Mobile Digital Specimen Radiography System for Intraoperative Specimen Verification
    Wang, Yingbing
    Ebuoma, Lilian
    Saksena, Mansi
    Liu, Bob
    Specht, Michelle
    Rafferty, Elizabeth
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (02) : 457 - 462
  • [8] Diagnostic performance of tomosynthesis, digital mammography and a dedicated digital specimen radiography system versus pathological assessment of excised breast lesions
    Almasarweh, Sa'ed
    Sudah, Mazen
    Okuma, Hidemi
    Joukainen, Sarianna
    Karja, Vesa
    Vanninen, Ritva
    Masarwah, Amro
    [J]. RADIOLOGY AND ONCOLOGY, 2022, 56 (04) : 461 - 470
  • [9] INTRAOPERATIVE SPECIMEN RADIOGRAPHY IN MAMMOGRAPHICALLY SUSPICIOUS, NONPALPABLE LESIONS OF THE BREAST, EXPERIENCES WITH THE X-RAY UNIT FAXITRON
    KURZL, R
    BALTZER, J
    LOHE, KJ
    [J]. FORTSCHRITTE DER MEDIZIN, 1979, 97 (38) : 1688 - 1690
  • [10] Comparison of dedicated digital specimen radiography with direct digital specimen mammography images
    JC Morel
    V Milnes
    A Iqbal
    MJ Michell
    [J]. Breast Cancer Research, 13