Kinetic-catalytic method for sequential determination of iron and copper using a chip coupled to a multipumping flow system

被引:0
|
作者
Abouhiat, Fatima Zohra [1 ,2 ]
Henriquez, Camelia [3 ]
El Yousfi, Farida [1 ]
Cerda, Ictor [2 ]
机构
[1] Univ Abdelmalek Essaadi, Fac Sci, Dept Chem, Tetouan 93002, Mexico
[2] Univ Balearic Isl, Dept Analyt Chem, Palma de Mallorca 07122, Spain
[3] Univ Sao Paulo, Ctr Nucl Energy Agr, BR-13400970 Piracicaba, SP, Brazil
关键词
SPECTROPHOTOMETRIC DETERMINATION; TRACE AMOUNTS; SAMPLES; HYDROXYLAMINE; OXIDATION;
D O I
10.1039/c5ay00799b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A kinetic-catalytic spectrophotometric method for the sequential determination of iron and copper is presented in this work. For this, a multipumping flow system (MPFS) has been coupled to a monolithic flow conductor, called a chip. The reaction is based on the catalytic effect of Cu(II) and Fe(III) on hydroxylamine oxidation in a basic medium. The addition of EDTA inhibits the Cu(II) catalytic effect and the reaction becomes selective for Fe(III). The nitrite produced is spectrophotometrically measured using a modified Griess reagent. Due to the importance of the mixing order of the reagents, a special design of the chip is proposed. The sample, hydroxylamine and buffer (with EDTA for Fe and without EDTA for Cu determination) have been simultaneously propelled into the thermostated first section of the chip for mixing and reaction at 40 degrees C. Then, this mixture and the modified Griess reagent (sulphanilamide and N-(1-naphthyl) ethylenediamine) have been injected by confluence into the second section of the chip. Under optimal conditions, the determinable range was 3-75 mu g L-1 and 70-350 mu g L-1 for Cu(II) and Fe(III) respectively, with a sample throughput of 32 h(-1) for Fe(III) and 39 h(-1) for Cu(II). The limits of detection were 0.95 mu g L-1 for Cu(II) and 21 mu g L-1 for Fe(III). The relative standard deviations (n - 6) were 1.6% for 50 mu g L-1 Cu(II) and 1.3% for 100 mu g L-1 Fe(III). The proposed method has been successfully applied to the sequential determination of Cu(II) and Fe(III) in wastewater and pharmaceutical samples. ICP-OES has been used as a reference method for validation.
引用
收藏
页码:7858 / 7865
页数:8
相关论文
共 50 条
  • [1] Sensitive kinetic-catalytic spectrophotometric method for cobalt determination using a chip coupled to a multisyringe flow injection analysis system
    Zohra Abouhiat, Fatima
    Henriquez, Camelia
    El Yousfi, Farida
    Cerda, Victor
    [J]. TALANTA, 2017, 166 : 405 - 411
  • [2] Automated in-chip kinetic-catalytic method for molybdenum determination
    Phansi, Piyawan
    Henriquez, Camelia
    Palacio, Edwin
    Nacapricha, Duangjai
    Cerda, Victor
    [J]. TALANTA, 2014, 119 : 68 - 74
  • [3] An automated in-chip-catalytic-spectrophotometric method for determination of copper(II) using a multisyringe flow injection analysis-multipumping flow system
    Phansi, Piyawan
    Henriquez, Camelia
    Palacio, Edwin
    Nacapricha, Duangjai
    Cerda, Victor
    [J]. ANALYTICAL METHODS, 2014, 6 (21) : 8494 - 8504
  • [4] DETERMINATION OF COPPER(II) BY KINETIC-CATALYTIC OXIDATION OF FERROCENE
    KAMAYA, M
    OHURI, I
    KAGAYAMA, K
    ISHII, E
    MURAKAMI, T
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (08): : 918 - 918
  • [5] A multisyringe flow-based system for kinetic-catalytic determination of cobalt(II)
    Chaparro, Laura
    Ferrer, Laura
    Leal, Luz
    Cerda, Victor
    [J]. TALANTA, 2015, 133 : 94 - 99
  • [6] DIFFERENTIAL DETERMINATION OF IODATE AND IODIDE BY A KINETIC-CATALYTIC METHOD
    TOMIYASU, T
    SAKAMOTO, H
    YONEHARA, N
    [J]. ANALYTICAL SCIENCES, 1994, 10 (02) : 293 - 297
  • [7] KINETIC-CATALYTIC DETERMINATION IN A 2-PHASE SYSTEM USING VERTICAL GLASS TUBE
    WEISZ, H
    MEINERS, W
    [J]. TALANTA, 1979, 26 (08) : 769 - 772
  • [8] Ruthenium(III) determination by kinetic-catalytic method using, the nile blue-acidic chlorite reaction
    Qwabe, L. Q.
    Pare, B.
    Jonnalagadda, S. B.
    [J]. BULLETIN OF THE CHEMICAL SOCIETY OF ETHIOPIA, 2007, 21 (02) : 171 - 178
  • [9] Kinetic-catalytic determination of iodide using the gallocyanine hydrogen peroxide redox reaction
    Ensafi, AA
    Chamjangali, MA
    [J]. CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 1999, 44 (05): : 126 - 130
  • [10] Determination of trace amounts of oxalate in vegetable and water samples using a new kinetic-catalytic reaction system
    Chamjangali, Mansour Arab
    Sharif-Razavian, Laleh
    Yousefi, Mohammad
    Amin, Amir Hossein
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2009, 73 (01) : 112 - 116