Validation of biplane high-speed fluoroscopy combined with two different noninvasive tracking methodologies for measuring invivo distal limb kinematics of the horse

被引:5
|
作者
Geiger, S. M. [1 ]
Reich, E. [1 ]
Boettcher, P. [2 ]
Grund, S. [1 ]
Hagen, J. [1 ]
机构
[1] Univ Leipzig, Inst Vet Anat Histol & Embryol, Fac Vet Med, Leipzig, Germany
[2] Free Univ Berlin, Small Anim Clin, Dept Vet Med, Berlin, Germany
关键词
horse; computer tomography; bone models; 3-dimensional gait analysis; validation; XROMM; locomotion; SOFT-TISSUE ARTIFACT; MOTION ANALYSIS; IMAGING TECHNIQUE; JOINT KINEMATICS; TROTTING HORSES; 3D KINEMATICS; ACCURACY; RECONSTRUCTION; FORELIMB; MARKERS;
D O I
10.1111/evj.12717
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Reason for performing studyBiplane high-speed fluoroscopy is a new method for gait analysis of the equine distal extremity. This is the first study validating the noninvasive tracking possibilities (Autoscoping and Scientific Rotoscoping) taking equine anatomy into account. ObjectivesTo determine the resolution with which Autoscoping and Scientific Rotoscoping depict motion of the equine phalanges in comparison to the invasive gold standard marker-based registration. Study designComparative exvivo study. MethodsIn 5 distal extremities of slaughtered ponies, 3 or 4 tantalum beads with 1mm diameter were implanted in each of the proximal, middle and distal phalangeal bones. Three-dimensional models of the bones were reconstructed using computed tomographic data (120kV, 50mA, slice thickness 1mm, increment 0.5). The beads were digitally removed from the bone models. Biplane fluoroscopic videos were taken at 69.53.5kV, 102.522.5mA, 500frames/s and 0.5ms shutter speed. The 5 specimens were moved in the trial field of the biplane fluoroscopic setup in a step-like motion (simulation of landing, main stance phase, lift-off). Marker-based registration, Autoscoping and Scientific Rotoscoping were carried out. For statistical analysis agreement was computed as percentiles, mean and s.d. ResultsThe medians of Scientific Rotoscoping ranged from 0.16 to 0.66mm in translations and 0.43 to 2.78 degrees in rotations, while values for Autoscoping were 0.13-0.70mm and 0.28-2.39 degrees respectively. With 2 exceptions, all differences between methods were statistically significant. Scientific Rotoscoping is more time efficient than Autoscoping and results in smaller maximum errors. Main limitationsThe experimental set-up was specifically designed to accommodate invivo requirements. Autoscoping was not manually corrected but rather expected to work automatically. ConclusionsIt is possible to noninvasively apply both Autoscoping and Scientific Rotoscoping for gait analysis of the equine phalanges with high precision. The summary is available in Chinese - see supporting information.
引用
下载
收藏
页码:261 / 269
页数:9
相关论文
共 2 条
  • [1] Validation of 2 noninvasive, markerless reconstruction techniques in biplane high-speed fluoroscopy for 3-dimensional research of bovine distal limb kinematics
    Weiss, M.
    Reich, E.
    Grund, S.
    Muelling, C. K. W.
    Geiger, S. M.
    JOURNAL OF DAIRY SCIENCE, 2017, 100 (10) : 8372 - 8384
  • [2] Sagittal distal limb kinematics inside the hoof capsule captured using high-speed fluoroscopy in walking and trotting horses
    Roach, J. M.
    Pfau, T.
    Bryars, J.
    Unt, V.
    Channon, S. B.
    Weller, R.
    VETERINARY JOURNAL, 2014, 202 (01): : 94 - 98