Capsular bag pacification with a new accommodating intraocular lens

被引:21
|
作者
Floyd, Anne M. [1 ]
Werner, Liliana [1 ]
Liu, Erica [1 ]
Stallings, Shannon [1 ]
Ollerton, Andrew [1 ]
Leishman, Lisa [1 ]
Bodnar, Zachary [1 ]
Morris, Caleb [1 ]
Mamalis, Nick [1 ]
机构
[1] Univ Utah, John A Moran Eye Ctr, Dept Ophthalmol & Visual Sci, Salt Lake City, UT 84132 USA
来源
关键词
SPRING ACTION; OPACIFICATION; RABBIT; PREVENTION; EFFICACY; RING; EYES; INTERLEUKIN-1; IMPLANTATION; DESIGN;
D O I
10.1016/j.jcrs.2013.01.051
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the biocompatibility and capsular bag opacification of an accommodating intraocular lens (IOL) containing large haptic elements that separate the anterior and posterior capsules. SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. DESIGN: Experimental study. METHODS: Bilateral phacoemulsification with IOL implantation was performed in 6 New Zealand rabbits. Each animal received a study (accommodating) IOL and a control (1-piece hydrophobic acrylic) IOL. Eyes were examined at the slitlamp from 1 day through 6 weeks postoperatively. The globes were then enucleated and evaluated grossly. Capsular bag opacification was scored from the posterior aspect (Miyake-Apple view). The eyes were then processed for complete histopathologic evaluation. RESULTS: At 6 weeks, the mean posterior capsule opacification (PCO) clinical score was 0.5 +/- 0.3 (SD) in the study group and 3.0 +/- 0.9 in the control group (P=.001, 2-tail paired t test). Anterior capsule opacification was practically absent in the study group and mild in the control group. Miyake-Apple posterior view showed a mean central PCO score of 0 +/- 0 in the study group and 3.0 +/- 1.1 in the control group (P=.001), peripheral PCO score of 0.7 +/- 0.4 and 3.5 +/- 0.8 (P=.0006), respectively, and Soemmerring ring score of 2.3 +/- 0.8 and 7.0 +/- 2.8 (P=.01), respectively. Histopathology showed no signs of toxicity in any eye. CONCLUSIONS: The study IOL maintained an expanded capsular bag secondary to the large size of the haptic elements, which appears to prevent capsular bag opacification.
引用
收藏
页码:1415 / 1420
页数:6
相关论文
共 50 条
  • [1] Capsular bag refilling using a new accommodating intraocular lens
    Nishi, Okihiro
    Nishi, Kayo
    Nishi, Yutaro
    Chang, Shiao
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (02): : 302 - 309
  • [2] Capsular bag opacification after experimental implantation of a new accommodating intraocular lens in rabbit eyes
    Werner, L
    Pandey, SK
    Izak, AM
    Vargas, LG
    Trivedi, RH
    Apple, DJ
    Mamalis, N
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (05): : 1114 - 1123
  • [3] Anterior haptic flexing and in-the-bag subluxation of an accommodating intraocular lens due to excessive capsular bag contraction
    Kramer, Gregory D.
    Werner, Liliana
    Neuhann, Tobias
    Tetz, Manfred
    Mamalis, Nick
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (09): : 2010 - 2013
  • [4] Capsular bag distension with an acrylic intraocular lens
    Omar, O
    Eng, CT
    Chang, A
    Durcan, FJ
    Liss, RP
    Stark, BI
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 : 1365 - 1367
  • [5] Dislocation of capsular bag with intraocular lens and capsular tension ring
    Oner, F. Hakan
    Kocak, Nilufer
    Saatci, A. Osman
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (10): : 1756 - 1758
  • [6] Long-term uveal and capsular biocompatibility of a new accommodating intraocular lens
    Kohl, Justin C.
    Werner, Liliana
    Ford, Joshua R.
    Cole, Scott C.
    Vasavada, Shall A.
    Gardiner, Gareth L.
    Noristani, Rozina
    Mamalis, Nick
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (12): : 2113 - 2119
  • [7] Capsular block syndrome after implantation of an accommodating intraocular lens
    Alessio, Giovanni
    L'Abbate, Milena
    Boscia, Francesco
    La Tegola, Maria Gabriella
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (04): : 703 - 706
  • [8] Ideal size of an intraocular lens for capsular bag fixation
    Lim, SJ
    Kang, SJ
    Kim, HB
    Apple, DJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (03): : 397 - 402
  • [9] Evaluation of stability and capsular bag opacification of a new foldable adjustable intraocular lens
    MacLean, Kyle D.
    Werner, Liliana
    Kramer, Gregory D.
    Farukhi, M. Aabid
    Gardiner, Gareth L.
    Kahook, Malik Y.
    Mamalis, Nick
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 43 (07): : 648 - 654
  • [10] Dead bag syndrome-in the capsular bag subluxated intraocular lens centration and refixation: A new technique
    Thakur, Anchal
    Bansal, Muskaan
    Challa, Divya
    Malhotra, Chintan
    Jain, Arun K.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2023, 71 (10) : 3412 - 3414