Scheme to reconstruct phase current information of inverter fed AC drives

被引:10
|
作者
Wolbank, TM [1 ]
Macheiner, P [1 ]
机构
[1] Vienna Univ Technol, Dept Elect Drives & Machines, A-1040 Vienna, Austria
关键词
D O I
10.1049/el:20020172
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In modern inverter fed AC drives the current control loop is usually realised by applying two current sensors in the phases of the machine. Different schemes have been presented in the past which enable a current control loop with a single current sensor in the DC link. At low fundamental frequencies they all need to modify the standard pulse-width modulation (PWM) scheme periodically in order to update the phase current values. Here, an advanced method is presented which improves the accuracy of the phase current reconstruction, thus reducing the necessary modification of the PWM.
引用
收藏
页码:204 / 205
页数:2
相关论文
共 50 条
  • [1] Severity and Impact of Faults on Current Harmonics in Inverter-Fed AC Drives
    Jyothi, R.
    Jayapal, R.
    Rao, K. Uma
    2016 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT-ASIA), 2016, : 401 - 405
  • [2] Overmodulation strategies of inverter-fed ac drives
    Halász, S
    Varjasi, I
    Zacharov, A
    PCC-OSAKA 2002: PROCEEDINGS OF THE POWER CONVERSION CONFERENCE-OSAKA 2002, VOLS I - III, 2002, : 1346 - 1351
  • [3] Voltage spectra of two-phase PWM techniques in inverter fed AC drives
    Halasz, S
    Zaharov, A
    IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE 98) - PROCEEDINGS, VOLS 1 AND 2, 1998, : 202 - 207
  • [4] Continuous PWM strategies of multi-phase inverter-fed AC drives
    Halász, Sándor
    Periodica polytechnica Electrical engineering and computer science, 2012, 56 (02): : 51 - 62
  • [5] Integral variable structure controller for current control of PWM inverter-fed AC drives
    Chung, SK
    ELECTRIC MACHINES AND POWER SYSTEMS, 1999, 27 (07): : 753 - 769
  • [6] High-speed inverter-fed AC drives
    Binder, A.
    Schneider, T.
    INTERNATIONAL AEGEAN CONFERENCE ON ELECTRICAL MACHINES AND POWER ELECTRONICS & ELECTROMOTION, PROCEEDINGS, 2007, : 9 - 16
  • [7] Automatic operation of pulsed inverter-fed AC drives
    Ruff, M
    ELECTROMECHANICAL DRIVE TECHNOLOGY 1997, 1997, 1346 : 129 - 148
  • [8] Two-phase modulation technique for three-level inverter fed AC drives
    Halasz, S
    Huu, BT
    Zakharov, A
    MELECON '98 - 9TH MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, VOLS 1 AND 2, 1998, : 1209 - 1213
  • [9] Analysis model of leakage current in a long shield power cable in inverter-fed AC drives
    Funato, H
    Bandou, M
    Kamiyama, K
    ELECTRICAL ENGINEERING IN JAPAN, 2002, 140 (02) : 65 - 72
  • [10] Common Mode Voltage Elimination Scheme for Dual-Inverter fed Five Phase AC Drives with Open-end Stator Windings
    Rajeevan, P. P.
    Abu-Rub, Haitham
    Iqbal, Atif
    Gopakumar, K.
    2013 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2013, : 1680 - 1685