Experimental thermal bowing response of precast concrete insulated wall panels with stiff shear connectors and simple supports

被引:0
|
作者
Arevalo, Sergio [1 ]
Tomlinson, Douglas [1 ]
机构
[1] Univ Alberta, Dept Civil & Environm Engn, Edmonton, AB, Canada
来源
关键词
SANDWICH; DAMAGE;
D O I
10.1016/j.jobe.2020.101319
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Precast concrete Insulated Wall Panels (IWP) are thermally and structurally efficient systems used in buildings. Although their flexural behaviour has been studied in detail, there is limited research on thermal bowing of IWP. Bowing causes undesirable deflection and stresses that are not well addressed in design guides. Four 6.1 m long panels with Glass Fibre Reinforced Polymer (GFRP) shear connectors were tested using a thermal enclosure that in duced temperature differentials over 20 degrees C. The stiffness of the 9.5-16 mm diameter shear connectors used in the full panels was found with 18 push-through tests on representative segments of the larger panels. The connector stiffness ranged between 26 and 59 kN/m and is stiff relative to other connector systems reported in the literature. Thermal load caused bowing that ranged between 39 and 44% of the Canadian concrete design standard (A23.3-14) acceptable service load deflection at a 20 degrees C temperature differential. Thermal load cracked the IWP and loaded connectors beyond their proportional limit. The amount of thermal bowing at a 20 degrees C temperature differential increased 16% with an 82% increase in connector stiffness. Results of these tests in dicate that bowing is significant in panels with high connection stiffness and may be a concern in long panels designed to carry axial loads.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Experimental thermal bowing response of precast concrete insulated wall panels with stiff shear connectors and simple supports
    Arevalo, Sergio
    Tomlinson, Douglas
    [J]. Journal of Building Engineering, 2020, 30
  • [2] Bowing of insulated precast concrete wall panels
    Losch, E
    [J]. PCI JOURNAL, 2003, 48 (06): : 126 - 129
  • [3] Investigation of Various GFRP Shear Connectors for Insulated Precast Concrete Sandwich Wall Panels
    Woltman, Greg
    Tomlinson, Douglas
    Fam, Amir
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2013, 17 (05) : 711 - 721
  • [4] Thermal bowing of concrete sandwich panels with flexible shear connectors
    Pozo-Lora, Fray
    Maguire, Marc
    [J]. JOURNAL OF BUILDING ENGINEERING, 2020, 29
  • [5] Design properties of insulated precast concrete sandwich panels with composite shear connectors
    Choi, Wonchang
    Jang, Seok-Joon
    Yun, Hyun-Do
    [J]. COMPOSITES PART B-ENGINEERING, 2019, 157 : 36 - 42
  • [6] Structural shear performance of insulated precast concrete sandwich panels with steel plate connectors
    Kinnane, Oliver
    West, Roger
    Hegarty, Richard O.
    [J]. ENGINEERING STRUCTURES, 2020, 215
  • [7] Experimental Investigation of Precast Concrete Insulated Sandwich Panels with Glass Fiber-Reinforced Polymer Shear Connectors
    Tomlinson, Douglas
    Fam, Amir
    [J]. ACI STRUCTURAL JOURNAL, 2014, 111 (03) : 595 - 605
  • [8] Experimental and numerical investigations of thermal properties of insulated concrete sandwich panels with fiberglass shear connectors
    Woltman, Gregory
    Noel, Martin
    Fam, Amir
    [J]. ENERGY AND BUILDINGS, 2017, 145 : 22 - 31
  • [9] Development and performance of a ductile shear tie for precast concrete insulated wall panels
    Gombeda, Matthew J.
    Naito, Clay J.
    Quiel, Spencer E.
    [J]. JOURNAL OF BUILDING ENGINEERING, 2020, 28
  • [10] Shear behavior of stainless-steel plate connectors for insulated precast concrete sandwich panels
    Lou, Xiaohang
    Xue, Weichen
    Bai, Haoyang
    Li, Ya
    Huang, Qian
    [J]. STRUCTURES, 2022, 44 : 1046 - 1056