Intraaortic balloon pumping in children

被引:26
|
作者
Akomea-Agyin, C
Kejriwal, NK
Franks, R
Booker, PD
Pozzi, M
机构
[1] Royal Liverpool Childrens Hosp Alder Hey, Dept Cardiac Surg, Liverpool L12 2AP, Merseyside, England
[2] Royal Liverpool Childrens Hosp Alder Hey, Dept Anaesthet, Liverpool L12 2AP, Merseyside, England
来源
ANNALS OF THORACIC SURGERY | 1999年 / 67卷 / 05期
关键词
D O I
10.1016/S0003-4975(99)00264-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Intraaortic balloon pump (IABP) usage in young children remains a rarity because, first, there is a widespread misconception that the greater elasticity of the aorta in children may prevent effective augmentation, and second, children in low cardiac output states are more likely to have associated right ventricular failure and pulmonary problems. We report our experience with the use of IABP in children undergoing cardiac surgery in whom mechanical support was necessary for the treatment of refractory cardiac failure. Methods. Over a 3-year period, 14 children were identified as requiring IABP support after cardiac surgery. Their median age was 3 years (range 7 days to 13 years) and their median weight was 13.3 kg (range 3.5-51 kg). Indications for IABP use were: failure to wean from cardiopulmonary bypass (5 patients), sudden deterioration in intensive therapy unit (ITU) (3 patients), progressive deterioration in ITU (4 patients), and prophylactic therapy for known poor preoperative ventricular function (2 patients). Results. Ten of 14 patients (71%) were successfully weaned from the IABP, of whom 8 became long-term survivors (57%). Among the survivors, the mean duration of IABP usage was 127 h (range 12-260 h), while for those who died while on IABP, the mean duration was 15 h (range 8-24 h). The most major IABP-related complication encountered was mesenteric ischemia, which had a fatal outcome. Conclusions. IABP therapy, used as an adjunct to conventional medical treatment, can give properly selected young children in refractory low cardiac output states after heart surgery a greater than 50% chance of long-term survival. (Ann Thorac Surg 1999;67:1415-20) (C) 1999 by The Society of Thoracic Surgeons.
引用
收藏
页码:1415 / 1420
页数:6
相关论文
共 50 条
  • [1] INTRAAORTIC BALLOON PUMPING
    KANTROWITZ, A
    TJONNELAND, S
    FREED, PS
    PHILLIPS, SJ
    BUTNER, AN
    SHERMAN, JL
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1968, 203 (11) : 988 - +
  • [2] Current results with Intraaortic balloon pumping in infants and children
    Pinkney, KA
    Minich, LL
    Tani, LY
    Di Russo, GB
    Veasy, LG
    McGough, EC
    Hawkins, JA
    ANNALS OF THORACIC SURGERY, 2002, 73 (03): : 887 - 891
  • [3] ORIGINS OF INTRAAORTIC BALLOON PUMPING
    KANTROWITZ, A
    ANNALS OF THORACIC SURGERY, 1990, 50 (04): : 672 - 674
  • [4] OPTIMAL CONTROLLER FOR INTRAAORTIC BALLOON PUMPING
    BARNEA, O
    SMITH, BT
    DUBIN, S
    MOORE, TW
    JARON, D
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (06) : 629 - 634
  • [5] ASSISTED CIRCULATION - INTRAAORTIC BALLOON PUMPING
    AUSTEN, WG
    BUCKLEY, MJ
    SANDERS, CA
    MUNDTH, ED
    TRANSPLANTATION PROCEEDINGS, 1971, 3 (04) : 1473 - &
  • [6] PEDIATRIC USE OF INTRAAORTIC BALLOON PUMPING
    VEASY, LG
    ORSMOND, GS
    RUTTENBERG, HD
    BOUCEK, MM
    PEDIATRIC CARDIOLOGY, 1983, 4 (04) : 310 - 310
  • [7] Physiology and biomechanics of intraaortic balloon pumping
    Chen, FY
    Aklog, L
    Couper, GS
    Cohn, LH
    ANNALS OF THORACIC SURGERY, 1997, 63 (01): : 294 - 296
  • [8] Paraplegia complicating intraaortic balloon pumping
    Hurle, A
    Llamas, P
    Meseguer, J
    Casillas, JA
    ANNALS OF THORACIC SURGERY, 1997, 63 (04): : 1217 - 1218
  • [9] Current results with intraaortic balloon pumping in infants and children - Invited commentary
    Delius, RE
    ANNALS OF THORACIC SURGERY, 2002, 73 (03): : 891 - 891
  • [10] Physiology and biomechanics of intraaortic balloon pumping - Reply
    Kim, SY
    Euler, DE
    Pifarre, R
    ANNALS OF THORACIC SURGERY, 1997, 63 (01): : 296 - 297