Attractive performance of a Gifford-McMahon cryocooler by co-axial layout of regenerator materials

被引:3
|
作者
Masuyama, Shinji [1 ]
Matsui, Kohei [1 ]
Tamura, Kota [1 ]
Numazawa, Takenori [2 ]
机构
[1] Oshima Natl Coll Maritime Technol, Yamaguchi, Japan
[2] Natl Inst Mat Sci, Tsukuba, Ibaraki, Japan
关键词
Gifford-McMahon cryocooler; Co-axial layout; Layer layout; Gd2O2S; HoCu2;
D O I
10.1016/j.cryogenics.2012.04.018
中图分类号
O414.1 [热力学];
学科分类号
摘要
A novel filling method of regenerator materials, which we name a co-axial layout, is experimentally investigated. The 2nd stage regenerator of a Gifford-McMahon cryocooler was packed with 50% by volume of the co-axial layout (low temperature side) that consisted of 20% Gd2O2S and 30% HoCu2 spheres. The warm temperature side was packed with 50% lead spheres as a single layer. The experimental results show that the cooling power of co-axial layout is almost the same as that of a three-layer layout, 20% Gd2O2S, 30% HoCu2 and 50% lead, at temperatures between the ultimate low temperature (3.0 K) and 6 K. Moreover, at the temperatures above 10 K, the co-axial layout has 1.7-2.0 times the cooling power of the three-layer layout. Thus the co-axial layout produces a major improvement in cooling power. In this paper, the performance of five types of material assortments is discussed. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:695 / 698
页数:4
相关论文
共 50 条
  • [1] Characteristics of a 1.6 W Gifford-McMahon Cryocooler with a Double Pipe Regenerator
    Masuyama, S.
    Numazawa, T.
    ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278
  • [2] AXIAL CONDUCTIVITY AND HEAT EXCHANGES IN A HYBRIDIZED GIFFORD-MCMAHON CRYOCOOLER
    BORCHI, E
    ZOLI, M
    FRIGO, A
    LOMBARDINI, L
    CRYOGENICS, 1989, 29 (03) : 196 - 199
  • [3] Development of SNSPD System With Gifford-McMahon Cryocooler
    Miki, Shigehito
    Fujiwara, Mikio
    Sasaki, Masahide
    Wang, Zhen
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) : 332 - 335
  • [4] Monolithic versus conventional packed bed second stage regenerator evaluation in a Gifford-McMahon cryocooler
    Wysokinski, TW
    Xu, XD
    Barclay, JA
    CRYOGENICS, 2002, 42 (11) : 691 - 696
  • [5] Low cost Gifford-McMahon cryocooler development program
    Kurtak, JS
    CRYOCOOLERS 9, 1997, : 607 - 615
  • [6] The characteristics of a 4 K Gifford-McMahon cryocooler with a second stage-regenerator packed with cenospheres
    Lavrenchenko, G. K.
    Kravchenko, M. B.
    LOW TEMPERATURE PHYSICS, 2019, 45 (04) : 452 - 464
  • [7] Helium liquefaction with a commercial 4 K Gifford-McMahon cryocooler
    Schmidt-Wellenburg, P.
    Zimmer, O.
    CRYOGENICS, 2006, 46 (11) : 799 - 803
  • [8] Effect of magnetic field on performance of ErNi0.9Co0.1 regenerator in Gifford-McMahon refrigerator
    Yayama, Hideki
    Low Temperature Physics, Pts A and B, 2006, 850 : 1577 - 1578
  • [9] A Gifford-McMahon cycle cryocooler below 2K
    Satoh, T
    Onishi, A
    Umehara, I
    Adachi, Y
    Sato, K
    Minehara, EJ
    CRYOCOOLERS 11, 2001, : 381 - 386
  • [10] Test apparatus utilizing a Gifford-McMahon cryocooler to measure the thermal performance of multilayer insulation
    Ohmori, T.
    Kodama, K.
    Tomaru, T.
    Kimura, N.
    Suzuki, T.
    PROCEEDINGS OF THE 25TH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2014, 2015, 67 : 999 - 1004