Development of a model system for preliminary evaluation of tissue-engineered vascular conduits

被引:13
|
作者
Goyal, Amit [1 ]
Wang, Yinong [1 ]
Su, Haili [1 ]
Dobrucki, Lawrence W. [1 ]
Brennan, Matthew [1 ]
Fong, Peter [1 ]
Dardik, Alan [1 ]
Tellides, George [1 ]
Sinusas, Albert [1 ]
Pober, Jordan S. [1 ]
Saltzman, W. Mark [1 ]
Breuer, Christopher K. [1 ]
机构
[1] Yale Univ, Dept Surg, New Haven, CT 06520 USA
关键词
tissue engineering; vascular conduit; SCID; mice; decellularized; ovine;
D O I
10.1016/j.jpedsurg.2006.02.019
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background/Purpose: The ability to construct tissue-engineered neovessels for use as arterial or venous grafts holds great promise for the advancement of pediatric surgical disciplines. Although the feasibility of tissue engineering vascular grafts has been demonstrated, the long-term function, safety, and efficacy of these grafts as well as their capacity to grow and adapt remain largely unknown. In all attempt to further characterize and develop this technology, we used severe combined immunodeficiency beige (SCID/bg) Mouse recipients, chosen because such animals accept xenogenic human cells, to create a small animal model that would allow a rapid and cost-effective preliminary evaluation of the function of tissue-engineered vascular grafts. Methods: Eight CB-17 SCID/bg female mice underwent vascular graft placement. Four of these mice received aortic interposition grafts, I mouse received an inferior vena cava interposition graft, and 3 mice underwent aortocaval graft insertion. All grafts were fashioned from decellularized ovine arteriole tissue engineering scaffolds. Grafts were evaluated for patency using clinical examination, ultrasound interrogation, and micro-computed tomography. Animals were killed at various time points after implantation, and grafts were harvested and analyzed histologically using standard hematoxylin and eosin staining. Results: All grafts were patent based on clinical examination for up to 35 days. Patency was confirmed in 5 grafts using ultrasound interrogation. Patency was confirmed in 4 grafts using micro-computed tomography. One animal that underwent arteriovenous grafting had to be euthanized secondary to high-output cardiac failure oil postoperative day 2. The remaining animals were killed between postoperative days 12 and 35. Histologic evaluation of the specimens demonstrated patent grafts with cellular ingrowth into the tissue engineering scaffold. Conclusions: From these results, we conclude that the use of the SCID/bg mouse model for preliminary evaluation of new tissue engineering methodologies for construction of vascular conduits is feasible. Use of this model has the added advantage of evaluating nonautologous and even xenograft tissues, including human cells. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:787 / 791
页数:5
相关论文
共 50 条
  • [1] Tissue-Engineered Urinary Conduits
    Max Kates
    Anirudha Singh
    Hotaka Matsui
    Gary D. Steinberg
    Norm D. Smith
    Mark P. Schoenberg
    Trinity J Bivalacqua
    [J]. Current Urology Reports, 2015, 16
  • [2] Tissue-Engineered Urinary Conduits
    Kates, Max
    Singh, Anirudha
    Matsui, Hotaka
    Steinberg, Gary D.
    Smith, Norm D.
    Schoenberg, Mark P.
    Bivalacqua, Trinity J.
    [J]. CURRENT UROLOGY REPORTS, 2015, 16 (03)
  • [3] Evaluation of tissue-engineered vascular autografts
    Matsumura, Goki
    Ishihara, Yoko
    Miyagawa-Tomita, Sachiko
    Ikada, Yoshito
    Matsuda, Shojiro
    Kurosawa, Hiromi
    Shin'oka, Toshiharu
    [J]. TISSUE ENGINEERING, 2006, 12 (11): : 3075 - 3083
  • [4] The development and translation of the tissue-engineered vascular graft
    Breuer, Christopher K.
    [J]. JOURNAL OF PEDIATRIC SURGERY, 2011, 46 (01) : 8 - 17
  • [5] Tissue-engineered valved conduits in the pulmonary circulation
    Stock, UA
    Nagashima, M
    Khalil, PN
    Nollert, GD
    Herden, T
    Sperling, JS
    Moran, A
    Lien, J
    Martin, DP
    Schoen, FJ
    Vacanti, JP
    Mayer, JE
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 119 (04): : 732 - 740
  • [6] Tissue-engineered vascular grafts
    Williams, SK
    Jarrell, BE
    [J]. NATURE MEDICINE, 1996, 2 (01) : 32 - 34
  • [7] Experimental study on tissue-engineered vascular model in vitro
    Xia, WS
    Lu, KH
    Ai, YF
    Xiong, M
    Zhang, LX
    Shu, MG
    [J]. TISSUE ENGINEERING, 2006, 12 (04): : 1088 - 1088
  • [8] Tissue-engineered valved conduits in the pulmonary circulation - Discussion
    Carpentier, AF
    Stock
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 119 (04): : 740 - 740
  • [9] Adherence of human saphenous vein endothelial cell monolayers to tissue-engineered biomatrix vascular conduits
    Birchall, IE
    Field, PL
    Ketharanathan, V
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 56 (03): : 437 - 443
  • [10] In Vivo Evaluation of a Tissue-Engineered Stem Cell Vascular Graft
    McIlhenny, Stephen E.
    Comeau, Jason A.
    Fernandez, Sarah I.
    Ferroni, Matthew C.
    Faul, Elizabeth J.
    Bagameri, Gabor
    Shapiro, Irving M.
    Tulenko, Thomas N.
    DiMuzio, Paul J.
    [J]. ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2010, 30 (11) : E222 - E222