Influence of robust optimization in intensity-modulated proton therapy with different dose delivery techniques

被引:72
|
作者
Liu, Wei [1 ]
Li, Yupeng [1 ]
Li, Xiaoqiang [1 ]
Cao, Wenhua [2 ]
Zhang, Xiaodong [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Houston, Dept Ind Engn, Houston, TX 77204 USA
关键词
robust optimization; IMPT; distal edge tracking; PENCIL BEAM ALGORITHM; TREATMENT UNCERTAINTIES; RANGE UNCERTAINTIES; PROSTATE-CANCER; RADIOTHERAPY; SENSITIVITY; APPROXIMATION; STRATEGY; ERRORS; TUMORS;
D O I
10.1118/1.4711909
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The distal edge tracking (DET) technique in intensity-modulated proton therapy (IMPT) allows for high energy efficiency, fast and simple delivery, and simple inverse treatment planning; however, it is highly sensitive to uncertainties. In this study, the authors explored the application of DET in IMPT (IMPT-DET) and conducted robust optimization of IMPT-DET to see if the planning technique's sensitivity to uncertainties was reduced. They also compared conventional and robust optimization of IMPT-DET with three-dimensional IMPT (IMPT-3D) to gain understanding about how plan robustness is achieved. Methods: They compared the robustness of IMPT-DET and IMPT-3D plans to uncertainties by analyzing plans created for a typical prostate cancer case and a base of skull (BOS) cancer case (using data for patients who had undergone proton therapy at our institution). Spots with the highest and second highest energy layers were chosen so that the Bragg peak would be at the distal edge of the targets in IMPT-DET using 36 equally spaced angle beams; in IMPT-3D, 3 beams with angles chosen by a beam angle optimization algorithm were planned. Dose contributions for a number of range and setup uncertainties were calculated, and a worst-case robust optimization was performed. A robust quantification technique was used to evaluate the plans' sensitivity to uncertainties. Results: With no uncertainties considered, the DET is less robust to uncertainties than is the 3D method but offers better normal tissue protection. With robust optimization to account for range and setup uncertainties, robust optimization can improve the robustness of IMPT plans to uncertainties; however, our findings show the extent of improvement varies. Conclusions: IMPT's sensitivity to uncertainties can be improved by using robust optimization. They found two possible mechanisms that made improvements possible: (1) a localized single-field uniform dose distribution (LSFUD) mechanism, in which the optimization algorithm attempts to produce a single-field uniform dose distribution while minimizing the patching field as much as possible; and (2) perturbed dose distribution, which follows the change in anatomical geometry. Multiple-instance optimization has more knowledge of the influence matrices; this greater knowledge improves IMPT plans' ability to retain robustness despite the presence of uncertainties. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4711909]
引用
收藏
页码:3089 / 3101
页数:13
相关论文
共 50 条
  • [1] Dose Interval Volume Constraint Based Robust Optimization of Intensity-Modulated Proton Therapy
    Shan, J.
    Liu, W.
    Au, Y.
    Schild, M.
    Bues, M.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2994 - 2995
  • [2] Robust Beam Orientation Optimization for Intensity-Modulated Proton Therapy
    Gu, W.
    Neph, R.
    Ruan, D.
    Zou, J.
    Dong, L.
    Sheng, K.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E257 - E258
  • [3] High Fidelity Robust Optimization for Intensity-Modulated Proton Therapy
    Gu, W.
    Ruan, D.
    Zou, J.
    Dong, L.
    Sheng, K.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E641 - E641
  • [4] Biological Based Robust Optimization for Intensity-Modulated Proton Therapy
    Bai, X.
    Lim, G.
    Grosshans, D.
    Mohan, R.
    Cao, W.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E643 - E643
  • [5] Robust beam orientation optimization for intensity-modulated proton therapy
    Gu, Wenbo
    Neph, Ryan
    Ruan, Dan
    Zou, Wei
    Dong, Lei
    Sheng, Ke
    [J]. MEDICAL PHYSICS, 2019, 46 (08) : 3356 - 3370
  • [6] Selective robust optimization: A new intensity-modulated proton therapy optimization strategy
    Li, Yupeng
    Niemela, Perttu
    Liao, Li
    Jiang, Shengpeng
    Li, Heng
    Poenisch, Falk
    Zhu, X. Ronald
    Siljamaki, Sami
    Vanderstraeten, Reynald
    Sahoo, Narayan
    Gillin, Michael
    Zhang, Xiaodong
    [J]. MEDICAL PHYSICS, 2015, 42 (08) : 4840 - 4847
  • [7] Region-Specific Robust Optimization for Intensity-Modulated Proton Therapy
    Liao, L.
    Chen, M.
    Adair, A.
    Zhu, X.
    Cao, W.
    Sahoo, N.
    Yang, M.
    Gunn, B.
    Frank, S.
    Zhang, X.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E481 - E481
  • [8] Robust Optimization in Intensity-Modulated Proton Therapy for Base-Of-Skull Cancers
    Liu, W.
    Mohan, R.
    Zhu, X.
    Grosshans, D.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [9] Robust optimization for intensity-modulated proton therapy with soft spot sensitivity regularization
    Gu, Wenbo
    Ruan, Dan
    O'Connor, Daniel
    Zou, Wei
    Dong, Lei
    Tsai, Min-Yu
    Jia, Xun
    Sheng, Ke
    [J]. MEDICAL PHYSICS, 2019, 46 (03) : 1408 - 1425
  • [10] Proton energy optimization and reduction for intensity-modulated proton therapy
    Cao, Wenhua
    Lim, Gino
    Liao, Li
    Li, Yupeng
    Jiang, Shengpeng
    Li, Xiaoqiang
    Li, Heng
    Suzuki, Kazumichi
    Zhu, X. Ronald
    Gomez, Daniel
    Zhang, Xiaodong
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (21): : 6341 - 6354