Comparison of fluid volume estimates in chronic hemodialysis patients by bioimpedance, direct isotopic, and dilution methods

被引:86
|
作者
Raimann, Jochen G. [1 ]
Zhu, Fansan [1 ]
Wang, Jack [2 ]
Thijssen, Stephan [1 ]
Kuhlmann, Martin K. [3 ]
Kotanko, Peter [1 ]
Levin, Nathan W. [1 ]
Kaysen, George A. [4 ]
机构
[1] Renal Res Inst, New York, NY 10065 USA
[2] St Lukes Roosevelt Hosp, New York, NY USA
[3] Vivantes Klinikum Friedrichshain, Berlin, Germany
[4] Univ Calif Davis, Davis, CA 95616 USA
关键词
chronic hemodialysis; hemodialysis; nutrition; water-electrolyte balance; BIOELECTRICAL-IMPEDANCE ANALYSIS; BODY CELL MASS; X-RAY ABSORPTIOMETRY; WATER; SPECTROSCOPY; POTASSIUM; VALIDATION; BROMIDE; SINGLE;
D O I
10.1038/ki.2013.358
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Bioimpedance analysis (BIA) is accepted for the assessment of total-body water (TBW), intracellular fluid (ICF) and extracellular fluid (ECF). We aimed to compare precision and accuracy of single and multi-frequency-BIA to direct estimation methods (DEMs) of TBW, ECF, and ICF in hemodialysis patients. Linear regression analysis of volume estimates in 49 patients by single-and multi-frequency-BIA correlated significantly with DEMs. Bland-Altman analysis (BAA) found systemic bias for ECF single-frequency-BIA vs. ECF-DEMs. No other systematic biases were found. Proportional errors were found by BAA of ICF and ECF assessments with single-and multi-frequency bioimpedance spectroscopy compared to the DEMs. Comparisons of indirect methods (IEMs) to DEMs showed no significant differences and proportional errors. Root mean-squared-error analysis suggested slightly better accuracy and precision of ICF single-frequency-BIA vs. DEMs over ICF multi-frequency-BIA and IEMs to DEMs, and slightly better performance for ECF multi-frequency-BIA over both respective other methods. Compared to DEMs, there is slightly better accuracy for ECF multi-over single-frequency-BIA and ICF single-over multi-frequency-BIA. However the margin of differences between direct and indirect methods suggests that none of the analyzed methods served as a true "gold standard'', because indirect methods are almost equally precise compared to DEMs.
引用
收藏
页码:898 / 908
页数:11
相关论文
共 50 条
  • [1] Estimation of fluid volumes in hemodialysis patients: comparing bioimpedance with isotopic and dilution methods
    Piccoli, Antonio
    KIDNEY INTERNATIONAL, 2014, 85 (04) : 738 - 741
  • [2] Estimating extracellular fluid volume in chronic hemodialysis patients:: A comparison between methods based on the volume of distribution of iohexol and multifrequency bioimpedance spectroscopy
    Tidman, Martin
    Sjotrom, Per
    Jones, Ian
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 : 185 - 185
  • [3] Segment-specific resistivity improves body fluid volume estimates from bioimpedance spectroscopy in hemodialysis patients
    Zhu, F
    Kuhlmann, MK
    Kaysen, GA
    Sarkar, S
    Kaitwatcharachai, C
    Khilnani, R
    Stevens, L
    Leonard, EF
    Wang, J
    Heymsfield, S
    Levin, NW
    JOURNAL OF APPLIED PHYSIOLOGY, 2006, 100 (02) : 717 - 724
  • [4] LUNG ULTRASONOGRAPHY AND BIOIMPEDANCE IN ASSESSMENT OF VOLUME STATUS OF HEMODIALYSIS PATIENTS: A COMPARISON BETWEEN BOTH METHODS
    Figueiredo, Catia
    Roldao, Marisa
    Valerio Alves, Ana Rita
    Goncalves, Hernani
    Sofia, Flora
    Lopes, Karina
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2021, 36 : 487 - 487
  • [5] BIOIMPEDANCE GUIDED DRY WEIGHT IN HEMODIALYSIS PATIENTS - COMPARISON OF METHODS
    Seibert, Eric
    Greinert, Daniel
    Dorligjav, Otgontogoo
    Mueller, Stephan
    Pattmoeller, Johanna
    Kotanko, Peter
    Levin, Nathan W.
    Girndt, Matthias
    Fiedler, Roman
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2016, 31 : 1491 - 1491
  • [6] Bioimpedance is not an accurate tool to detect volume overload in chronic hemodialysis patients
    Kuhn, Christian
    Rykow, Kai
    Saile, Peter
    Kuhn, Andrea
    Osten, Bernd
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 : 422 - 423
  • [7] MULTIFREQUENCY BIOIMPEDANCE ASSESSMENT OF VOLUME COMPARTMENTS IN CHRONIC-HEMODIALYSIS PATIENTS
    HO, LT
    GUDIVAKA, R
    SCHOELLER, D
    KUSHNER, R
    SPIEGEL, DM
    CLINICAL RESEARCH, 1993, 41 (03): : A655 - A655
  • [8] Comparison of multiple fluid status assessment methods in patients on chronic hemodialysis
    Alexiadis, Giannis
    Panagoutsos, Stelios
    Roumeliotis, Stefanos
    Stibiris, Ilias
    Markos, Angelos
    Kantartzi, Konstantia
    Passadakis, Ploumis
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2017, 49 (03) : 525 - 532
  • [9] Comparison of multiple fluid status assessment methods in patients on chronic hemodialysis
    Giannis Alexiadis
    Stelios Panagoutsos
    Stefanos Roumeliotis
    Ilias Stibiris
    Angelos Markos
    Konstantia Kantartzi
    Ploumis Passadakis
    International Urology and Nephrology, 2017, 49 : 525 - 532
  • [10] EVALUATION OF EXTRAVASCULAR FLUID IN HEMODIALYSIS PATIENTS BY LUNG ULTRASOUND IN COMPARISON WITH BIOIMPEDANCE
    Putintceva, Anastasiia
    Zdanova, Irina
    Tsukanova, Ekaterina
    Fadeeva, Julia
    Esayan, Ashot
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2021, 36