Non-Fourier encoding with multiple spin echoes

被引:18
|
作者
Panych, LP
Mulkern, RV
Saiviroonporn, P
Zientara, GP
Jolesz, FA
机构
[1] CHILDRENS HOSP,DEPT RADIOL,BOSTON,MA 02115
[2] BOSTON UNIV,DEPT BIOMED ENGN,BOSTON,MA 02215
关键词
magnetic resonance image encoding; non-Fourier encoded MRI; spatially selective RF excitation;
D O I
10.1002/mrm.1910380616
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The advantages and limitations of multiple spin-echo sequences for non-fourier encoding are investigated, Complications caused by improper encoding of alternate magnetization pathways due to imperfect refocusing pulses are analyzed, It is shown that mirror image ghosts result if the encoding RF pulse matrix is real-valued, These ghosts can be avoided as long as the rows of the RF pulse matrix are conjugate symmetric, which implies that spatial profiles are real valued, Non-Fourier encoding using bases derived from wavelet, Hadamard, and other real-valued orthogonal functions does not result in a mirror ghost artifact, A RARE sequence for non-fourier encoding has been implemented on a clinical imaging system and successfully applied for brain imaging.
引用
收藏
页码:964 / 973
页数:10
相关论文
共 50 条
  • [1] Time domain multiplexing for multichannel non-Fourier spatial encoding
    Bankson, JA
    Wright, SM
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 453 - 455
  • [2] Non-Fourier motion in the Fourier spectrum
    Beauchemin, SS
    INTERNATIONAL CONFERENCE ON IMAGING SCIENCE, SYSTEMS, AND TECHNOLOGY, PROCEEDINGS, 1999, : 423 - 428
  • [3] Emergence of Non-Fourier Hierarchies
    Fulop, Tamas
    Kovacs, Robert
    Lovas, Adam
    Rieth, Agnes
    Fodor, Tamas
    Szucs, Matyas
    Van, Peter
    Grof, Gyula
    ENTROPY, 2018, 20 (11)
  • [4] Fourier and non-Fourier pattern discrimination compared
    Lin, LM
    Wilson, HR
    VISION RESEARCH, 1996, 36 (13) : 1907 - 1918
  • [5] FOURIER AND NON-FOURIER TERMINATORS IN MOTION PERCEPTION
    ORBACH, HS
    WILSON, HR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1827 - 1827
  • [6] NON-FOURIER MOTION ANALYSIS
    CHUBB, C
    MCGOWAN, J
    SPERLING, G
    WERKHOVEN, P
    HIGHER-ORDER PROCESSING IN THE VISUAL SYSTEM, 1994, 184 : 193 - 205
  • [7] NON-FOURIER PLASMA ELECTRODYNAMICS
    SHVARTSBURG, AB
    PHYSICA SCRIPTA, 1994, 49 (03): : 351 - 355
  • [8] STEREOSCOPIC INTEGRATION OF FOURIER AND NON-FOURIER PATTERNS
    LIN, L
    WILSON, HR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S364 - S364
  • [9] PERCEIVED VELOCITY OF FOURIER AND NON-FOURIER STIMULI
    WITT, R
    CONTE, MM
    WARAN, M
    VICTOR, JD
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1269 - 1269
  • [10] Functional magnetic resonance imaging using non-Fourier, spatially selective radiofrequency encoding
    Yoo, SS
    Guttmann, CRG
    Panych, LP
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (04) : 759 - 766