Automatic measurement of fetal nuchal translucency from three-dimensional ultrasound data

被引:0
|
作者
Nie, Siqing [1 ]
Yu, Jinhua [1 ,2 ]
Chen, Ping [3 ]
Wang, Yuanyuan [1 ]
Guo, Yi [1 ]
Zhang, Jian Qiu [1 ]
机构
[1] Fudan Univ, Dept Elect Engn, Shanghai, Peoples R China
[2] Key Lab Med Imaging Comp & Comp Assisted Interven, Shanghai, Peoples R China
[3] Tongji Univ, Shanghai Matern & Infant Hosp 1, Dept Ultrasound, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
CROWN-RUMP LENGTH; CHROMOSOMAL DEFECTS; 1ST TRIMESTER; PREGNANCY;
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The Nuchal translucency (NT), which is the collection of fluid at the back of the fetal neck, is related to chromosomal defects and early cardiac failure in first trimester of pregnancy. In clinic, the thickness of NT is used as an important marker in prenatal screening, and is manually measured by sonographers in the mid-sagittal plane. In this paper, an automatic method based on dynamic programming is proposed to detect the thickness and area of NT in the mid-sagittal plane. Furthermore, the volume of NT in the whole three-dimensional ultrasound data is also measured. A novel cost function for dynamic programming is proposed and results in higher accuracy of NT border detection. As the nuchal translucency is the collection fluid part, higher dimensional markers of NT possess more potential to represent the amount of the fluid.
引用
收藏
页码:3417 / 3420
页数:4
相关论文
共 50 条
  • [1] Measurement of fetal nuchal translucency thickness by three-dimensional ultrasound
    Paul, C
    Krampl, E
    Skentou, C
    Jurkovic, D
    Nicolaides, KH
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2001, 18 (05) : 481 - 484
  • [2] Three-dimensional transvaginal ultrasound improves measurement of nuchal translucency
    Kurjak, A
    Kupesic, S
    Ivancic-Kosuta, M
    [J]. JOURNAL OF PERINATAL MEDICINE, 1999, 27 (02) : 97 - 102
  • [3] Three-dimensional ultrasound for nuchal translucency thickness measurements: Comparison of transabdominal and transvaginal ultrasound
    Worda, C
    Radner, G
    Lee, A
    Eppel, W
    [J]. JOURNAL OF THE SOCIETY FOR GYNECOLOGIC INVESTIGATION, 2003, 10 (06) : 361 - 365
  • [4] Three-Dimensional Ultrasound for Nuchal Translucency Thickness Measurements: Comparison of Transabdominal and Transvaginal Ultrasound
    Christof Wordan
    Gerald Radner
    Andreas Lee
    Wolfgang Eppel
    [J]. The Journal of the Society for Gynecologic Investigation: JSGI, 2003, 10 : 361 - 365
  • [5] The application of three-dimensional ultrasound to nuchal translucency thickness measurement at 10-14 weeks of gestation
    Chung, BL
    Kim, YP
    Nam, MH
    [J]. PRENATAL AND NEONATAL MEDICINE, 2000, 5 (01): : 17 - 21
  • [6] Fetal anatomic survey using three-dimensional ultrasound in conjunction with first-trimester nuchal translucency screening
    Bhaduri, Mousumi
    Fong, Katherine
    Toi, Ants
    Tomlinson, George
    Okun, Nan
    [J]. PRENATAL DIAGNOSIS, 2010, 30 (03) : 267 - 273
  • [7] Comparison between two- and three-dimensional ultrasound measurements of nuchal translucency
    Clementschitsch, G
    Hasenöhrl, G
    Schaffer, H
    Steiner, H
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2001, 18 (05) : 475 - 480
  • [8] Automatic Nuchal Translucency Measurement from Ultrasonography
    Park, JinHyeong
    Sofka, Michal
    Lee, Sunmi
    Kim, DaeYoung
    Zhou, S. Kevin
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION (MICCAI 2013), PT III, 2013, 8151 : 243 - 250
  • [9] Cat-eye syndrome in a fetus with increased nuchal translucency: three-dimensional ultrasound and echocardiographic evaluation of the fetal phenotype
    Volpe, P
    Buonadonna, AL
    Campobasso, G
    Di Carlo, A
    Stanziano, A
    Gentile, M
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2004, 24 (04) : 485 - 487
  • [10] Automatic detection and measurement of nuchal translucency
    Sciortino, Giuseppa
    Tegolo, Domenico
    Valenti, Cesare
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 82 : 12 - 20