Internal winding faults in three-phase five-limb transformer

被引:4
|
作者
Pérez-Rojas, C
García-Martínez, S
机构
关键词
transformer; saturation; internal winding faults;
D O I
10.1109/ICEEE.2005.1529633
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a three-phase five-limb transformer is used to include some changes to modelling internal winding faults. The developed model is based on primitive parameters and it takes into account the physical dimensions at different regions of the iron core, the nonlinear effects of magnetic saturation and the effect of internal windings faults on the three-phase transformer.
引用
收藏
页码:314 / 317
页数:4
相关论文
共 50 条
  • [1] Model of a five-limb amorphous core used in a three-phase distribution transformer
    Gacek, Z
    Soinski, M
    Sosinski, R
    NON-LINEAR ELECTROMAGNETIC SYSTEMS: ADVANCED TECHNIQUES AND MATHEMATICAL METHODS, 1998, 13 : 689 - 692
  • [2] Simplified models of three-phase, five-limb transformer for studying GIC effects
    Zirka, S. E.
    Moroz, Y. I.
    Elovaara, J.
    Lahtinen, M.
    Walling, R. A.
    Hoidalen, H. Kr
    Bonmann, D.
    Arturi, C. M.
    Chiesa, N.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 103 : 168 - 175
  • [3] Three-Phase Five-Limb Transformer Harmonic Analysis under DC-bias
    Murwira, Talent T.
    Mkhonta, Sizwe
    Oyedokun, David T. O.
    Folly, Komla A.
    Gaunt, C. T.
    2019 SOUTHERN AFRICAN UNIVERSITIES POWER ENGINEERING CONFERENCE/ROBOTICS AND MECHATRONICS/PATTERN RECOGNITION ASSOCIATION OF SOUTH AFRICA (SAUPEC/ROBMECH/PRASA), 2019, : 420 - 424
  • [4] Analysis of Nonlinear Characteristics for a Three-Phase, Five-Limb Transformer Under DC Bias
    Li, Xiaoping
    Wen, Xishan
    Markham, Penn N.
    Liu, Yilu
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) : 2504 - 2510
  • [5] A Duality Based Quasi-Steady-State Model of Three-Phase Five-Limb Sen Transformer
    Zhou, Chao
    Han, Song
    Rong, Na
    Liu, Min
    IEEE ACCESS, 2021, 9 : 115217 - 115226
  • [6] Finite Element Method Based Determination of Magnetic Loading of Three-Phase Five-Limb Transformer with Impact of DC Offset
    Kohli, Saurabh
    Mahajan, S. B.
    Badave, S. M.
    Sanjeevikumar, Padmanaban
    Iqbal, Atif
    ADVANCES IN POWER SYSTEMS AND ENERGY MANAGEMENT, 2018, 436
  • [7] Quasi steady-state model of three-phase five-limb ST based on duality principle
    Zhou C.
    Han S.
    Bu L.
    Pan Y.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2022, 42 (05): : 198 - 203and211
  • [8] Simulation of internal fault of three-phase five-leg transformer
    Department of Electrical Engineering, Southwest Jiaotong University, Chengdu 610031, China
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 2007, 8 (43-47):
  • [9] The Application of Correlation Technique in Detecting Internal and External Faults in Three-Phase Transformer and Saturation of Current Transformer
    Etumi, Adel A.
    Anayi, Fatih
    IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (05) : 2131 - 2139
  • [10] Modelling of three-limb wound magnetic core of three-phase transformer with disconnected neutral wire of primary winding
    Sosinski, Rafal
    PRZEGLAD ELEKTROTECHNICZNY, 2007, 83 (04): : 109 - 111