Phase sensitivity at the Heisenberg limit in an SU(1,1) interferometer via parity detection

被引:73
|
作者
Li, Dong [1 ,2 ,3 ]
Gard, Bryan T. [2 ,3 ]
Gao, Yang [4 ]
Yuan, Chun-Hua [1 ,5 ]
Zhang, Weiping [5 ,6 ]
Lee, Hwang [2 ,3 ]
Dowling, Jonathan P. [2 ,3 ]
机构
[1] East China Normal Univ, Dept Phys, Quantum Inst Light & Atoms, Shanghai 200062, Peoples R China
[2] Louisiana State Univ, Hearne Inst Theoret Phys, Baton Rouge, LA 70803 USA
[3] Louisiana State Univ, Dept Phys & Astron, Baton Rouge, LA 70803 USA
[4] Xinyang Normal Univ, Dept Phys, Xinyang 464000, Henan, Peoples R China
[5] Shanxi Univ, Collaborat Innovat Ctr Extreme Opt, Taiyuan 030006, Shanxi, Peoples R China
[6] Shanghai Jiao Tong Univ, Dept Phys & Astron, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金; 美国国家科学基金会;
关键词
QUANTUM OPTICAL METROLOGY; STATES; INFORMATION; OPERATOR;
D O I
10.1103/PhysRevA.94.063840
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We theoretically investigate the phase sensitivity with parity detection on an SU(1,1) interferometer with a coherent state combined with a squeezed vacuum state. This interferometer is formed with two parametric amplifiers for beam splitting and recombination instead of beam splitters. We show that the sensitivity of phase estimation approaches the Heisenberg limit and give the corresponding optimal condition. Moreover, we derive the quantum Cramer-Rao bound of the SU(1,1) interferometer.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Effects of loss on the phase sensitivity with parity detection in an SU(1,1) interferometer
    Li, Dong
    Yuan, Chun-Hua
    Yao, Yao
    Jiang, Wei
    Li, Mo
    Zhang, Weiping
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2018, 35 (05) : 1080 - 1092
  • [2] Phase sensitivity of an SU(1,1) interferometer via product detection
    Wang, Qingle
    Fang, Yami
    Ma, Xiaoping
    Li, Dong
    [J]. EPJ QUANTUM TECHNOLOGY, 2021, 8 (01)
  • [3] Improving the phase sensitivity of an SU (1,1) interferometer via a nonlinear phase encoding
    Seth, Osei
    Li, Xinfang
    Xiong, Heng-Na
    Luo, Junyan
    Huang, Yixiao
    [J]. JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2020, 53 (20)
  • [4] Improvement of phase sensitivity in an SU(1,1) interferometer via a phase shift induced by a Kerr medium
    Chang, Shoukang
    Ye, Wei
    Zhang, Huan
    Hu, Liyun
    Huang, Jiehui
    Liu, Sanqiu
    [J]. PHYSICAL REVIEW A, 2022, 105 (03)
  • [5] Phase sensitivity of an SU(1,1) interferometer in photon-loss via photon operations
    Xu, Youke
    Zhao, Teng
    Kang, Qingqian
    Liu, Cunjin
    Hu, Liyun
    Liu, Sanqiu
    [J]. OPTICS EXPRESS, 2023, 31 (05) : 8414 - 8427
  • [6] Absolute sensitivity of phase measurement in an SU(1,1) type interferometer
    Du, Wei
    Jia, Jun
    Chen, J. F.
    Ou, Z. Y.
    Zhang, Weiping
    [J]. OPTICS LETTERS, 2018, 43 (05) : 1051 - 1054
  • [7] Negativity of Wigner function and phase sensitivity of an SU(1,1) interferometer
    Liu, Chun-Li
    Guo, Li-Li
    Zhang, Zhi-Ming
    Yu, Ya-Fei
    [J]. CHINESE PHYSICS B, 2019, 28 (06)
  • [8] Negativity of Wigner function and phase sensitivity of an SU(1,1) interferometer
    刘春丽
    郭丽丽
    张智明
    於亚飞
    [J]. Chinese Physics B, 2019, 28 (06) : 121 - 125
  • [9] SU(1,1) Interferometer by Direct Detection
    Huo, Nan
    Guo, Xueshi
    Zhao, Wen
    Zhang, Yunxiao
    Li, Xiaoying
    Ou, Z. Y.
    [J]. 2021 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2021,
  • [10] Enhancement in phase sensitivity of SU(1,1) interferometer with Kerr state seeding
    Sharma, Priyanka
    Pandey, Aviral Kumar
    Shukla, Gaurav
    Mishra, Devendra Kumar
    [J]. Optics Communications, 2024, 573