Spatial distribution of steel fibers and air bubbles in UHPC cylinder determined by X-ray CT method

被引:88
|
作者
Wang, Rui [1 ]
Gao, Xiaojian [1 ,2 ,3 ]
Zhang, Junyi [1 ]
Han, Guangshuai [1 ]
机构
[1] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Heilongjiang, Peoples R China
[2] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Heilongjiang, Peoples R China
[3] Harbin Inst Technol, Minist Ind & Informat Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disast, Harbin 150090, Heilongjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
UHPC; Rheological properties; Homogeneity; X-ray CT; Splitting tensile strength; MECHANICAL-PROPERTIES; RHEOLOGICAL PROPERTIES; REINFORCED-CONCRETE; CEMENT PASTE; PERFORMANCE; WORKABILITY; MICROSTRUCTURE; SUSPENSIONS; COMPOSITES; DISPERSION;
D O I
10.1016/j.conbuildmat.2017.11.030
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigated the spatial distribution of steel fibers and air bubbles in UHPC cylinder specimen by using X-ray CT system. Four levels of superplasticizer dosage were adopted to obtain cement mortar mixtures with different rheological properties and then steel fibers were added by volume of 1%, 2% and 3% for every cement mortar mixture respectively. Cylindrical specimens with diameter of 100 mm and height of 200 mm were prepared under the same condition for every mixture and the content of steel fibers and air bubbles at different casting depth was determined by X-ray CT measurement. On the other hand, the cylinder specimen was cut into four pieces for evaluating the splitting tensile strength variation with the casting depth. The results reveal that steel fibers and air bubbles are uniformly distributed in UHPC specimen when the fresh mixture is prepared by adding a lower dosage of superplasticizer. This homogeneity is also proved by the splitting tensile strength for samples at different depths. When the yield stress of fresh mortar was reduced by the higher dosage of superplasticizer, the steel fiber sedimentation and air bubble rise occurred and the splitting tensile strength was significantly decreased at the top portion of cylinder specimen. The influence of steel fiber content on splitting tensile strength can be regressed into a good quadratic equation. Therefore, the balance between homogeneity and flowability should be fully considered for manufacturing UHPC elements with a high depth. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 50 条
  • [1] Spatial distribution of synthetic fibers in concrete with X-ray computed tomography
    Bordelon, Amanda C.
    Roesler, Jeffery R.
    CEMENT & CONCRETE COMPOSITES, 2014, 53 : 35 - 43
  • [2] LUNG-VOLUMES AND DISTRIBUTION OF REGIONAL AIR CONTENT DETERMINED BY CINE X-RAY CT OF PNEUMONECTOMIZED RABBITS
    OLSON, LE
    HOFFMAN, EA
    JOURNAL OF APPLIED PHYSIOLOGY, 1994, 76 (04) : 1774 - 1785
  • [3] Spatial distribution of voids in Hy-100 steel by X-ray tomography
    Everett, RK
    Simmonds, KE
    Geltmacher, AB
    SCRIPTA MATERIALIA, 2001, 44 (01) : 165 - 169
  • [4] Artefact on CT brain images caused by the presence of air bubbles in the cooling oil of the X-ray tube
    Trieu, Nelson
    Xia, Ryan
    Loneragan, Robert
    Ridley, Lloyd
    Trieu, Joseph
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2017, 61 (02) : 197 - 203
  • [5] Fiber-Distribution Assessment in Steel Fiber-Reinforced UHPC Using Conventional Imaging, X-Ray CT Scan, and Concrete Electrical Conductivity
    Ruan, T.
    Poursaee, A.
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2019, 31 (08)
  • [6] The cleanability of stainless steel as determined by X-ray photoelectron spectroscopy
    Boyd, RD
    Verran, J
    Hall, KE
    Underhill, C
    Hibbert, S
    West, R
    APPLIED SURFACE SCIENCE, 2001, 172 (1-2) : 135 - 143
  • [7] MRI and X-ray CT study of spatial distribution of core breakdown in 'Conference' pears
    Lammertyn, J
    Dresselaers, T
    Van Hecke, P
    Jancsók, P
    Wevers, M
    Nicolaï, BM
    MAGNETIC RESONANCE IMAGING, 2003, 21 (07) : 805 - 815
  • [8] Spatial and temporal motion characterization for x-ray CT
    Hsieh, Jiang
    MEDICAL PHYSICS, 2024, 51 (07) : 4607 - 4621
  • [9] Optimization method for x-ray CT exposure
    Tsujioka, K
    Ida, Y
    Chikamatsu, H
    Goka, S
    Mori, Y
    Katada, K
    RADIOLOGY, 1996, 201 : 824 - 824
  • [10] SPATIAL DISTRIBUTION OF X-RAY SOURCE IN A PLASMA FOCUS
    HAI, F
    BERNSTEI.MJ
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1970, 15 (11): : 1463 - &