Clinical value of triple-energy window scatter correction in simultaneous dual-isotope single-photon emission tomography with I-123-BMIPP and Tl-201

被引:0
|
作者
Yang, JT [1 ]
Yamamoto, K [1 ]
Sadato, N [1 ]
Tsuchida, T [1 ]
Takahashi, N [1 ]
Hayashi, N [1 ]
Yonekura, Y [1 ]
Ishii, Y [1 ]
机构
[1] FUKUI MED SCH,BIOMED IMAGING RES CTR,MATSUOKA,FUKUI 91011,JAPAN
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1997年 / 24卷 / 09期
关键词
dual-isotope single-photon emission tomography; triple-energy window method; iodine-123; BMIPP; thallium-201; coronary artery disease;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To improve the image quality in simultaneous dual-isotope single-photon emission tomography (SPET) with iodine-123 labelled 15-(p-iodophenyl)-3-methylpentadecanoic acid (BMTPP) and thallium-201, we applied the triple-energy window method (TEW) for correction of the cross-talk and scatter artifact. Seventy-one patients with coronary artery disease were included. Tl-201 cross-talk into the I-123 acquisition window (group I, n = 30) and I-123 cross-talk into the Tl-201 window (group 2, n = 41) were studied. Tn group 1, I-123 images were first obtained (single-isotope images), followed by Tl-201 injection and SPET acquisition using dual-isotope windows (dual-isotope images). In group 2, the order was reversed, The dual-isotope SPET images with and without TEW were compared with the single-isotope images. Qualitative evaluation was performed by scoring the segmental defect pattern. Detectability of the mismatched fatty acid metabolism on dual-isotope SPET was evaluated by receiver operating characteristic (ROC) curve analysis. Segmental defect pattern agreement between dual and corrected single images was significantly improved by TEW correction (P<0.01). The agreement was particularly improved in segments with absence of uptake, There was no significant difference between TEW-corrected dual-isotope SPET and corresponding single-isotope SPET with regard to either % defect count or background activity. Mismatched fatty acid metabolism depicted by dual-isotope SPET predicted abnormal wall motion more accurately with TEW than without TEW. With TEW, a practical method for scatter and cross-talk correction in clinical settings, simultaneous dual I-123-BMIPP/Tl-201 SPET is feasible for the assessment of myocardial perfusion/metabolism mismatch.
引用
收藏
页码:1099 / 1106
页数:8
相关论文
共 41 条
  • [1] Clinical value of triple-energy window scatter correction in simultaneous dual-isotope single-photon emission tomography with 123I-BMIPP and 201TI
    Yang J.-T.
    Yamamoto K.
    Sadato N.
    Tsuchida T.
    Takahashi N.
    Hayashi N.
    Yonekura Y.
    Ishii Y.
    European Journal of Nuclear Medicine, 1997, 24 (9) : 1099 - 1106
  • [2] CLINICAL USEFULNESS OF THE TRIPLE ENERGY WINDOW METHOD FOR CROSSTALK CORRECTION IN DUAL-ISOTOPE ACQUISITION OF TL-201CL AND I-123 BMIPP MYOCARDIAL SPECT
    UEHARA, T
    NISHIMURA, T
    MOROZUMI, T
    YAMAGAMI, H
    FUKUCHI, K
    KUBOTA, M
    HASEGAWA, H
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P194 - P195
  • [3] A new method for crosstalk correction in simultaneous dual-isotope myocardial imaging with Tl-201 and I-123
    Akinori Tsuji
    Akihiro Kojima
    Masanori Matsumoto
    Yoichi Oyama
    Seiji Tomiguchi
    Tomohiro Kira
    Yoshikazu Takagi
    Osamu Shimomura
    Mutsumasa Takahashi
    Annals of Nuclear Medicine, 1999, 13 : 317 - 323
  • [4] COMPTON SCATTER COMPENSATION USING THE TRIPLE-ENERGY WINDOW METHOD FOR SINGLE-ISOTOPE AND DUAL-ISOTOPE SPECT
    ICHIHARA, T
    OGAWA, K
    MOTOMURA, N
    KUBO, A
    HASHIMOTO, S
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (12) : 2216 - 2221
  • [5] Evaluation of Triple-energy Window Method with Two Approximations for Scatter Correction Studies in Single-photon Emission Computed Tomography Imaging Using GATE
    Seifabadi, Mohammad
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2015, 46 (03) : 317 - 324
  • [6] Optimization of scatter correction method in samarium-153 single-photon emission computed tomography using triple-energy window: A monte carlo simulation study
    Asmi, Hicham
    Bentayeb, Farida
    Bouzekraoui, Youssef
    Bonutti, Faustino
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2020, 35 (03): : 210 - 215
  • [7] Usefulness of CT attenuation correction for 201Tl/123I-BMIPP dual-isotope myocardial SPECT on CZT camera
    Yoshimura, S.
    Tomiguchi, S.
    Sakamoto, F.
    Matsubara, T.
    Shiraishi, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S199 - S200
  • [8] Comparison of the dual-energy window method and the triple-energy window method for quantitative single photon emission computed tomography
    Ito, Y.
    Kuniyoshi, M.
    Suetake, M.
    Mochizuki, K.
    Matsumoto, K.
    Endo, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S647 - S647
  • [9] Clinical Feasibility of Simultaneous Acquisition Rest 99mTc/Stress 201Tl Dual-Isotope Myocardial Perfusion Single-Photon Emission Computed Tomography With Semiconductor Camera
    Makita, Ayano
    Matsumoto, Naoya
    Suzuki, Yasuyuki
    Hori, Yusuke
    Kuronuma, Keiichiro
    Yoda, Shunichi
    Kasama, Shu
    Iguchi, Nobuo
    Suzuki, Yasuhiro
    Hirayama, Atsushi
    CIRCULATION JOURNAL, 2016, 80 (03) : 689 - 695
  • [10] 123I-β-Methyl Iodophenyl Pentadecanoic Acid and 201Thallium Dual Myocardial Single-Photon Emission Computed Tomography (BMIPP/Tl SPECT) Detection of Myocardial Damage of Systemic Sclerosis
    Kawano, Hiroaki
    Kudo, Takashi
    Maemura, Koji
    CIRCULATION JOURNAL, 2020, 84 (10) : 1886 - 1886