Latched Limit Strategy for Single-phase Synchronous Inverter for Realization of Designed Grid Forming Performance

被引:0
|
作者
Sekizaki, Shinya [1 ]
Yorino, Naoto [1 ]
Sasaki, Yutaka [1 ]
Zoka, Yoshifumi [1 ]
Shimizu, Toshihisa [2 ]
Nishizaki, Ichiro [1 ]
机构
[1] Hiroshima Univ, Grad Sch Adv Sci & Engn, Higashihiroshima, Hiroshima, Japan
[2] Tokyo Metropolitan Univ, Tokyo, Japan
来源
IFAC PAPERSONLINE | 2022年 / 55卷 / 09期
关键词
single-phase synchronous inverter; grid forming inverter; single-phase microgrid; latched limit strategy; overcurrent suppression; POWER; SYNCHRONVERTER; VSCS;
D O I
10.1016/j.ifacol.2022.07.077
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Single-phase synchronous inverters (SSIs) with synthetic inertia connect to single-phase circuits and stabilize the grid. They also improve grid resilience by forming and operating an islanded single-phase microgrid when disasters disconnect the single-phase circuits from the bulk power system. Generally, voltage and current feedback controllers are implemented in grid-connected converters to track the output voltage to the voltage reference and protect themselves from overcurrent when the fault occurs. However, controllers with multiple feedback control loops in SSIs impair the grid stabilization performance depending on grid frequency variations. Without optimal parameter tuning according to grid conditions, they also cause instability of the controller during the islanding operation of a singlephase microgrid. This paper proposes a controller to realize the designed grid forming performance and avoid the above problems inherent in SSIs. The SSI with the proposed controller works as a grid forming inverter in a normal condition without the multiple feedback loops, stabilizing the grid and operating a single-phase microgrid stably. When an overcurrent is detected, the SSI shifts from a grid forming mode to a current control mode using a latched limit strategy to protect semiconductor devices from the overcurrent. Since the appropriate switching between the two modes is essential for realizing the designed performance of the SSI, the proposed controller employs a modified current-trip voltagereset limit. Numerical simulations and experiments demonstrate that the proposed controller provides the designed performance in both normal and faulted conditions. Copyright (C) 2022 The Authors.
引用
收藏
页码:442 / 447
页数:6
相关论文
共 50 条
  • [1] Single-phase Synchronous Inverter with Overcurrent Protection using Current Controller with Latched Limit Strategy
    Sekizaki, Shinya
    Yorino, Naoto
    Sasaki, Yutaka
    Zoka, Yoshifumi
    Shimizu, Toshihisa
    Nishizaki, Ichiro
    [J]. IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2023, 18 (06) : 1001 - 1014
  • [2] A Development of A Single-phase Synchronous Inverter for Grid Resilience and Stabilization
    Sekizaki, Shinya
    Sasaki, Yutaka
    Yorino, Naoto
    Zoka, Yoshifumi
    Nakamura, Yuki
    Nishizaki, Ichiro
    [J]. 2017 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT-ASIA), 2017, : 614 - 619
  • [3] Development of Single-Phase Synchronous Inverter for Single-Phase Microgrid
    Yorino, Naoto
    Zoka, Yoshifumi
    Sasaki, Yutaka
    Sekizaki, Shinya
    Yokonuma, Mitsuo
    Himuro, Takahiro
    Kuroki, Futoshi
    Fujii, Toshinori
    Inoue, Hirotaka
    [J]. ELECTRONICS, 2024, 13 (03)
  • [4] Realization of a Single-Phase Multilevel Inverter for Grid-Connected Photovoltaic System
    Nouaiti, Ayoub
    Mesbahi, Abdelouahed
    Saad, Abdallah
    Khafallah, Mohamed
    Reddak, Moussa
    [J]. ENGINEERING TECHNOLOGY & APPLIED SCIENCE RESEARCH, 2018, 8 (05) : 3344 - 3349
  • [5] Research on control strategy for single-phase grid-connected inverter
    Institute of Electrical Engineering, Yanshan University, Qinhuangdao 066004, China
    [J]. Zhongguo Dianji Gongcheng Xuebao, 2007, 16 (60-64):
  • [6] An Enhanced Control Strategy for Seamless Transfer of Grid-connected Single-Phase Inverter in Synchronous Rotating Frame
    Kim, Bum-Jun
    Cho, Jin-Ho
    Kim, Jung-Min
    Lee, Jung-Hyo
    Won, Chung-Yuen
    [J]. 2017 20TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2017,
  • [7] Grid-connected control for single-phase inverter based on synchronous frame transformation
    Shijiazhuang University of Economics, Shijiazhuang 050031, China
    不详
    [J]. Dianli Xitong Baohu yu Kongzhi, 2009, 17 (75-77):
  • [8] Gain scheduling control strategy for a single-phase grid-connected inverter
    Jiao, Jiao
    Hung, John Y.
    Nelms, R. M.
    [J]. 2017 IEEE 26TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2017, : 723 - 728
  • [9] A Virtual Synchronous Generation Strategy for a Single-Phase Grid-Connected qZSI
    Diaz, Manuel A.
    Ramirez, Roberto
    Torres, Miguel A.
    Saavedra, Jorge
    Rohten, Jaime
    Baier, Carlos R.
    [J]. 2018 IEEE INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2018,
  • [10] Design of a Virtual Synchronous Generator Strategy for a Single-Phase Current-Source Inverter
    Torres, Miguel
    Baier, Carlos
    [J]. 2015 IEEE 24TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2015, : 482 - 487