Embolization of a high-output postnephrectomy aortocaval fistula with Gianturco coils and cyanoacrylate

被引:19
|
作者
Cekirge, S
Oguzkurt, L
Saatci, I
Boyvat, F
Balkanci, F
机构
关键词
arteriovenous fistula; kidney; embolization; coils;
D O I
10.1007/s002709900013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The authors describe the endovascular treatment of a high-output, large-caliber, postnephrectomy aortocaval fistula using a mixture of cyanoacrylate and lipiodol combined with Gianturco coil embolization. Thirty-nine coils were used to decrease the flow through the fistula so that a fast-polymerizing glue mixture could be injected into the fistula. During rapid polymerization, the N-butyl-2-cyanoacrylate (NBCA) mixture was trapped within the coils, providing an easily controllable glue cast in the fistula, thereby preventing inadvertent embolization into the lungs. This approach can be of considerable benefit for thee endovascular treatment of central high-output fistulas.
引用
收藏
页码:56 / 58
页数:3
相关论文
共 50 条
  • [1] AORTOCAVAL FISTULA CAUSING HIGH-OUTPUT HEART FAILURE
    Dominguez, Bianca M.
    Gosine, Adhiraj D.
    CHEST, 2024, 166 (04) : 414A - 415A
  • [2] High-Output Heart Failure Resulting From Chronic Aortocaval Fistula
    Lebon, Alain
    Agueznai, Moaad
    Labombarda, Fabien
    CIRCULATION, 2013, 127 (04) : 527 - 528
  • [3] Closure of a High-output Postoperative Pancreatic Fistula Grade B by Percutaneous Embolization with N-butyl-cyanoacrylate
    Rott, Gernot
    Gaina, Maria Magdalena
    Boecker, Frieder
    Simon, Dietmar
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 45 (02) : 268 - 269
  • [4] Closure of a High-output Postoperative Pancreatic Fistula Grade B by Percutaneous Embolization with N-butyl-cyanoacrylate
    Gernot Rott
    Maria Magdalena Gaina
    Frieder Boecker
    Dietmar Simon
    CardioVascular and Interventional Radiology, 2022, 45 : 268 - 269
  • [5] Aortocaval fistula on point-of-care ultrasound: a potential cause of high-output cardiac failure
    Aisha Batool
    Abhilash Koratala
    Internal and Emergency Medicine, 2023, 18 : 2135 - 2137
  • [6] Aortocaval fistula on point-of-care ultrasound: a potential cause of high-output cardiac failure
    Batool, Aisha
    Koratala, Abhilash
    INTERNAL AND EMERGENCY MEDICINE, 2023, 18 (07) : 2135 - 2137
  • [7] Endovascular Repair of Contained Abdominal Aortic Aneurysm Rupture With Aortocaval Fistula Presenting With High-Output Heart Failure
    Shah, Tejas R.
    Parikh, Parin
    Borkon, Matthew
    Mocharla, Robert
    Lonier, Jacqueline
    Rosenzweig, Barry P.
    Mussa, Firas F.
    VASCULAR AND ENDOVASCULAR SURGERY, 2013, 47 (01) : 51 - 56
  • [8] High Output Heart Failure from an Aortocaval Fistula
    Diaz, Laura Wubker
    Spence-Miller, Shanice
    Sancassani, Rhea
    Bornak, Arash
    Colombo, Rosario
    CIRCULATION, 2024, 150
  • [9] High-output cardiac failure secondary to high-output arteriovenous fistula: investigations, management and definitive treatment
    Hartley, James Leon
    Sharma, Asheesh
    Taha, Lamis
    Hestletine, Thomas
    BMJ CASE REPORTS, 2020, 13 (02)
  • [10] High-output heart failure secondary to arteriovenous fistula
    Stern, Adam B.
    Klemmer, Philip J.
    HEMODIALYSIS INTERNATIONAL, 2011, 15 (01) : 104 - 107