Analysis of red cell parameters on the Sysmex XE 2100 and ADVIA 120 in iron deficiency and in uraemic chronic disease

被引:23
|
作者
David, O
Grillo, A
Ceoloni, B
Cavallo, F
Podda, G
Biancotti, PP
Bergamo, D
Canavese, C
机构
[1] Amedeo Avogadro Univ, Maggiore Hosp, Dept Nephrourol, Novara, Italy
[2] S Giovanni Battista Hosp, Dept Clin Pathol, Turin, Italy
[3] Regina Margherita S Anna Hosp, Dept Clin Pathol, Turin, Italy
关键词
anaemia; hypochromic-cell percentage ( HYPO); recombinant human erythropoietin (r-HuEPO); regular dialysis treatment (RDT); reticulocyte; reticulocyte haemoglobin content (CHr);
D O I
10.1080/00365510500406910
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective. The percentage measurement of hypochromic red cells ( HYPO) and reticulocyte haemoglobin content (CHr) using the ADVIA system has recently been validated as a useful tool in indicating iron deficiency, also in cases of chronic diseases such as renal failure. The aim of this study was to evaluate the extent to which the red cell parameters, RBC-Y and RET-Y, provided by Sysmex XE 2100, correlate with HYPO and CHr. Material and methods. The laboratory markers of iron status were evaluated together with HYPO, CHr, RBC-Y and RET-Y in 92 healthy subjects ( C), 42 iron-deficient patients ( ID) and 88 uraemic patients receiving regular dialysis treatment (RDT). Results. In ID patients, increased HYPO and decreased RBC-Y, CHr and RET-Y values, with no overlapping with reference values, were found and a significant correlation was present between ADVIA 120 and Sysmex indices ( p<0.001 for each correlation). In RDT patients, HYPO median values were increased with a wide distribution of values (95% reference range = 0.7 - 27.5 % and 0.7 - 22.6 % in men and women, respectively). In contrast, RBC-Y was normal/increased ( 95 % reference range = 169.4 - 191.1 and 168.7 - 190.5 in men and women, respectively), even though there was a significant correlation between them ( p<0.001). CHr and RET-Y values were within the reference range; moreover, in these patients mean cell volume of red cells and of reticulocytes (MCV and MCVr) median values were increased. Conclusions. This study confirmed the validity of RBC-Y in the management of ID, but not in RDT, where the diagnostic power of RBC-Y as an index of cell hypochromia is limited owing to high MCV values.
引用
收藏
页码:113 / 120
页数:8
相关论文
共 50 条
  • [1] New red cell parameters on the Sysmex XE-2100™ as potential markers of functional iron deficiency
    Briggs, C
    Rogers, R
    Thompson, B
    Machin, SJ
    [J]. INFUSION THERAPY AND TRANSFUSION MEDICINE-INFUSIONSTHERAPIE UND TRANSFUSIONSMEDIZIN, 2001, 28 (05): : 256 - 262
  • [2] Platelet counting by the Coulter LH 750, Sysmex XE 2100, and Advia 120
    Sandhaus, LM
    Osei, ES
    Agrawal, NN
    Dillman, CA
    Meyerson, HJ
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2002, 118 (02) : 235 - 241
  • [3] BASOPHIL COUNT ON CELL-DYN SAPPHIRE, SYSMEX XE-2100 AND ADVIA 120 EVALUATED BY A FLOW CYTOMETRIC METHOD
    Amundsen, E. K.
    Henriksson, C. E.
    Holthe, M. R.
    Urdal, P.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S457 - S457
  • [4] Hematological indices of Sysmex XE-2100 analyser in the evaluation of iron deficiency in dialysed patients
    Maconi, Mariacaterina
    Cavalca, Leandra
    Canovi, Laura
    Cardarelli, Francesca
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2007, 29 : 56 - 57
  • [5] Rapid identification of iron deficiency in blood donors with red cell indexes provided by Advia 120
    Radtke, H
    Meyer, T
    Kalus, U
    Röcker, L
    Salama, A
    Kiesewetter, H
    Latza, R
    [J]. TRANSFUSION, 2005, 45 (01) : 5 - 10
  • [6] AUTOMATED CELL COUNTING OF BODY FLUIDS: EVALUATION OF THE ABX PENTRA DX 120 COMPARED TO THE MANUAL MICROSCOPE METHOD, THE SIEMENS ADVIA 2120 AND THE SYSMEX XE 2100
    Danise, P.
    Rovetti, A.
    Ricciardi, C.
    Esposito, C.
    Di Palma, A.
    Avino, D.
    Pirofalo, M. G.
    Talento, B.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S718 - S718
  • [7] Comparison of four hematology analyzers, CELL-DYN Sapphire, ADVIA 120, Coulter LH 750, and Sysmex XE-2100, in terms of clinical usefulness
    Kang, S. -H.
    Kim, H. K.
    Ham, C. K.
    Lee, D. S.
    Cho, H. -I.
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2008, 30 (06) : 480 - 486
  • [8] The Advia 120 red blood cell and reticulocyte indices are useful in diagnosis of iron-deficiency anemia
    Kotisaari, S
    Romppanen, J
    Penttilä, I
    Punnonen, K
    [J]. EUROPEAN JOURNAL OF HAEMATOLOGY, 2002, 68 (03) : 150 - 156
  • [9] Stability of hematological analytes depends on the hematology analyser used: A stability study with Bayer Advia 120, Beckman Coulter LH 750 and Sysmex XE 2100
    Imeri, Fatime
    Herklotz, Roberto
    Risch, Lorenz
    Arbetsleitner, Christine
    Zerlauth, Manfred
    Risch, Gerhard M.
    Huber, Andreas R.
    [J]. CLINICA CHIMICA ACTA, 2008, 397 (1-2) : 68 - 71
  • [10] Comparison of Automated Differential Blood Cell Counts From Abbott Sapphire, Siemens Advia 120, Beckman Coulter DxH 800, and Sysmex XE-2100 in Normal and Pathologic Samples
    Meintker, Lisa
    Ringwald, Juergen
    Rauh, Manfred
    Krause, Stefan W.
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2013, 139 (05) : 641 - 650