Computer-Assisted Surgical Navigation Does Not Improve the Alignment and Orientation of the Components in Total Knee Arthroplasty

被引:100
|
作者
Kim, Young-Hoo [1 ]
Kim, Jun-Shik [1 ]
Choi, Yoowang [1 ]
Kwon, Oh-Ryong [1 ]
机构
[1] Ewha Womans Univ, Ctr Joint Replacement, Mok Dong Hosp, Seoul 158710, South Korea
来源
关键词
CONVENTIONAL TECHNIQUE; REPLACEMENT; TRIAL; EXPERIENCE; PLACEMENT; ROTATION; SUPPORT;
D O I
10.2106/JBJS.G.01700
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Whether total knee arthroplasty with use of computer-assisted surgical navigation can improve the limb and component alignment is a matter of debate. We hypothesized that total knee arthroplasty with use of computer-assisted surgical navigation is superior to conventional total knee arthroplasty with regard to the precision of implant positioning. Methods: Sequential simultaneous bilateral total knee arthroplasties were carried out in 160 patients (320 knees). One knee was replaced with use of a computer-assisted surgical navigation system, and the other was replaced conventionally without use of computer-assisted surgical navigation. The two methods were compared for accuracy of orientation and alignment of the components as determined by radiographs and computed tomography scans. The mean duration of follow-up was 3.4 years. Results: The mean preoperative Knee Society score was 26 points, with an improvement to 92 points postoperatively, in the computer-assisted total knee arthroplasty group and 25 points, with an improvement to 93 points postoperatively, in the conventional total knee arthroplasty group. Preoperative and postoperative ranges of motion of the knees were similar in both groups. The operating and tourniquet times were significantly longer in the computer-assisted total knee arthroplasty group than in the conventional total knee arthroplasty group (p < 0.001). The groups were not significantly different with regard to the accuracy of component positioning and the number of outliers for the various radiographic parameters (p > 0.05). Conclusions: Our data demonstrate that total knee arthroplasty with use of computer-assisted surgical navigation did not result in more accurate implant positioning than that achieved in conventional total knee arthroplasty, as determined by both radiographs and computed tomography scans.
引用
收藏
页码:14 / 19
页数:6
相关论文
共 50 条
  • [1] Computer-Assisted Navigation in Total Knee Arthroplasty
    Mathew, Kevin K.
    DeGouveia, William
    Marchand, Kevin B.
    Ehiorobo, Joseph O.
    Tarazi, John M.
    Sodhi, Nipun
    Salem, Hytham S.
    Mont, Michael A.
    [J]. SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2020, 36
  • [2] Computer-assisted navigation in total knee arthroplasty
    de Zwart, P. M.
    Weise, K.
    Ochs, U.
    [J]. TRAUMA UND BERUFSKRANKHEIT, 2010, 12 (02) : 107 - 112
  • [3] Does computer-assisted surgical navigation total knee arthroplasty reduce venous thromboembolism compared with conventional total knee arthroplasty?
    Ooi, L. H.
    Lo, N. N.
    Yeo, S. J.
    Ong, B. C.
    Ding, Z. P.
    Lefi, A.
    [J]. SINGAPORE MEDICAL JOURNAL, 2008, 49 (08) : 610 - 614
  • [4] Computer-Assisted Navigation Software Advancements Improve the Accuracy of Total Knee Arthroplasty
    Molli, Ryan G.
    Anderson, Kevin C.
    Buehler, Knute C.
    Markel, David C.
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (03): : 432 - 438
  • [5] Computer-Assisted Navigation-Total Knee Arthroplasty
    O'Malley, Michael J.
    Klatt, Brian A.
    [J]. OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2012, 22 (04) : 176 - 181
  • [6] Computer-assisted total knee arthroplasty: Navigation in TKA
    Krackow, KA
    Phillips, MJ
    Bayers-Thering, M
    Serpe, L
    Mihalko, WM
    [J]. ORTHOPEDICS, 2003, 26 (10) : 1017 - 1023
  • [7] Reliability of Imageless Computer-Assisted Navigation for Femoral Rotational Alignment in Total Knee Arthroplasty
    Leelasestaporn, C.
    Thuwapitchayanant, M.
    Sirithanapipat, P.
    Sa-ngasoongsong, P.
    Ruengsilsuwit, P.
    [J]. MALAYSIAN ORTHOPAEDIC JOURNAL, 2021, 15 (01) : 79 - 84
  • [8] Computer-assisted revision total knee arthroplasty does not improve postoperative knee prosthesis alignment compared to the conventional technique
    Alling, Triine E.
    Conteh-Meijer, Marrigje F.
    Boerboom, Alexander L.
    Stevens, Martin
    Reininga, Inge H. F.
    [J]. JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [9] Prosthetic alignment and sizing in computer-assisted total knee arthroplasty
    Tomoyuki Matsumoto
    Nobuhiro Tsumura
    Masahiro Kurosaka
    Hirotsugu Muratsu
    Ryosuke Kuroda
    Katsuhiko Ishimoto
    Kazuo Tsujimoto
    Ryoichi Shiba
    Shinichi Yoshiya
    [J]. International Orthopaedics, 2004, 28 : 282 - 285
  • [10] Prosthetic alignment and sizing in computer-assisted total knee arthroplasty
    Matsumoto, T
    Tsumura, N
    Kurosaka, M
    Muratsu, H
    Kuroda, R
    Ishimoto, K
    Tsujimoto, K
    Shiba, R
    Yoshiya, S
    [J]. INTERNATIONAL ORTHOPAEDICS, 2004, 28 (05) : 282 - 285