Performance Analysis And Radiometric Correction of Novel Molecular Hyperspectral Imaging System

被引:6
|
作者
Liu Hong-ying [1 ]
Li Qing-li [1 ]
Gu Bin [1 ]
Wang Yi-ting [2 ]
Xue Yong-qi [3 ]
机构
[1] E China Normal Univ, Key Lab Polar Mat & Devices, Shanghai 200241, Peoples R China
[2] E China Normal Univ, Inst Adv Interdisciplinary Res, Shanghai 200062, Peoples R China
[3] Chinese Acad Sci, Shanghai Inst Tech Phys, Shanghai 200083, Peoples R China
关键词
MHSI; AOTF; Performance; Calibration;
D O I
10.3964/j.issn.1000-0593(2012)11-3161-06
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Integrating molecular imaging technology and hyperspectral technology, a novel molecular hyperspectral imaging (MHSI) system based on AOTF was presented. The system consists of microscope, spectrometer, matrix CCD, image collection card and computer. The system's performance was synthetically evaluated referring every part's performance. The spectral range of the MHSI system is from 550 to 1 000 nm. Two hundred twenty five bands can be continuously captured at a time. The spectral resolution is less than 2 nm. The spatial resolution is about 0.061 5 mu m. CCD acquisition speed achieved 2.612 5 s . B-1 in the integration mode and about 0.11 mu s . B-1 in the non-integration mode. Due to the infection of lamp, a spectral curve extracted directly from the original hyperspectral data can not truly present biochemical character and needs to be corrected. The paper proposes the gray correction coefficient algorithm with spatial dimension and spectral dimension, and gives concrete realization of the algorithm. Taking the sample of leukemia blood, by comparing the single-band images, pseudo-color images and spectra before and after correction, the results indicate the effectiveness of correction algorithm. The corrected data is effective for subsequent analysis.
引用
收藏
页码:3161 / 3166
页数:6
相关论文
共 9 条
  • [1] A novel optical imaging method for the early detection, quantitative grading, and mapping of cancerous and precancerous lesions of cervix
    Balas, C
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (01) : 96 - 104
  • [2] In vivo quantification of fluorescent molecular markers in real-time by ratio Imaging for diagnostic screening and image-guided surgery
    Bogaards, A.
    Sterenborg, H. J. C. M.
    Trachtenberg, J.
    Wilson, B. C.
    Lilge, L.
    [J]. LASERS IN SURGERY AND MEDICINE, 2007, 39 (07) : 605 - 613
  • [3] Fauvel M., 2009, REMOTE SENS ENVIRON, V113, P110, DOI DOI 10.1016/J.RSE.2007.07.028
  • [4] Kherlopian Armen, 2008, BMC SYSTEMS BIOL, V2, P74
  • [5] [李庆利 LI Qingli], 2008, [影像科学与光化学, Imaging Science and Photochemistry], V26, P507
  • [6] Tongue color analysis and discrimination based on hyperspectral images
    Li Qingli
    Liu Zhi
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2009, 33 (03) : 217 - 221
  • [7] An AOTF-based dual-modality hyperspectral imaging system (DMHSI) capable of simultaneous fluorescence and reflectance imaging
    Martin, ME
    Wabuyele, M
    Panjehpour, M
    Overholt, B
    DeNovo, R
    Kennel, S
    Cunningham, G
    Vo-Dinh, T
    [J]. MEDICAL ENGINEERING & PHYSICS, 2006, 28 (02) : 149 - 155
  • [8] Neelam G, 2005, ACOUSTOOPTIC TUNABLE, P5953
  • [9] Vo-Dinh T, 2004, IEEE ENG MED BIOL, V23, P40