A theoretical CHF model for downward facing surfaces and gaps under saturated boiling

被引:16
|
作者
Yu, Hongxing [1 ,2 ]
Zhang, Yapei [1 ]
Su, Guanghui [1 ]
Qiu, Suizheng [1 ]
Tian, Wenxi [1 ]
机构
[1] Xi An Jiao Tong Univ, Dept Nucl Sci & Technol, Xian 710049, Peoples R China
[2] Nucl Power Inst China, Chengdu 610041, Peoples R China
基金
中国国家自然科学基金;
关键词
CHF; Bubble hydrodynamics; Surface orientation; Gap size; Severe accident; CRITICAL HEAT-FLUX; VESSEL LOWER PLENA; SEVERE ACCIDENT; REACTOR VESSEL; NATURAL-CONVECTION; ORIENTATION; NUCLEATE; PRESSURE; PLATES; SPACE;
D O I
10.1016/j.ijmultiphaseflow.2012.05.001
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
A theoretical model is developed to predict the critical heat flux (CHF) based on the description of the hydrodynamic behavior of the vapor-liquid interface of a bubble at the heater surface leading to the initiation of CHF condition under saturated boiling. The CHF model considering heater size and gap size effects is developed to account for surface orientation effect, gap size effect, pressure effect, and contact angle effect for downward facing surfaces and gaps with orientations of 0 degrees (horizontal downward facing position) to 90 degrees (vertical position). The CHF in pool boiling and gap boiling was well predicted by the model for different effects. And the CHF model was extended to predict the CHF of the reactor-scaling hemispherical surface. The results indicated that the CHF model could also well predict the experimental data on large scale hemispherical surface. The present work is instructive for the safety analysis of the lower head of PWR in case of core meltdown during severe accident. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:30 / 39
页数:10
相关论文
共 50 条
  • [1] A hydrodynamic CHF model for downward facing boiling on a coated vessel
    Yang, J
    Cheung, FB
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2005, 26 (03) : 474 - 484
  • [2] Saturated pool boiling from downward facing structured surfaces with grooves
    Zhong D.
    Meng J.
    Li Z.
    Huagong Xuebao/CIESC Journal, 2016, 67 (09): : 3559 - 3565
  • [3] Effect of metal honeycomb structure on enhancing CHF in saturated downward-facing flow boiling
    Wang, Laishun
    Yuan, Yuan
    Erkan, Nejdet
    Li, Fengchen
    Okamoto, Koji
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 149
  • [4] Experimental study of saturated pool boiling from downward facing structured surfaces
    Zhong, Dawen
    Meng, Jian
    Li, Zhixin
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2016, 108 : 52 - 61
  • [5] TRANSIENT BOILING FROM INCLINED AND DOWNWARD-FACING SURFACES IN A SATURATED POOL
    ELGENK, MS
    GUO, ZX
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1993, 16 (06): : 414 - 422
  • [6] Experimental study of saturated pool boiling from downward facing surfaces with artificial cavities
    Zhong, Dawen
    Meng, Ji'an
    Li, Zhixin
    Guo, Zengyuan
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2015, 68 : 442 - 451
  • [7] AN EXPERIMENTAL-STUDY OF SATURATED POOL BOILING FROM DOWNWARD FACING AND INCLINED SURFACES
    GUO, ZX
    ELGENK, MS
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1992, 35 (09) : 2109 - 2117
  • [8] Experimental investigation on saturated pool boiling CHF for downward facing heating surface with different sizes and aspect ratio
    Zhang, Yapei
    Deng, Kuanghan
    Wang, Chenglong
    Su, G. H.
    Tian, Wenxi
    Qiu, Suizheng
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 138 : 459 - 466
  • [9] Oxidation effect of copper on the downward-facing flow boiling CHF under atmospheric condition
    Wang, Kai
    Erkan, Nejdet
    Okamoto, Koji
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 156 (156)
  • [10] Critical heat flux for downward-facing saturated pool boiling on pin fin surfaces
    Zhong, Dawen
    Meng, Ji'an
    Li, Zhixin
    Guo, Zengyuan
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 87 : 201 - 211