Glucose-responsive microneedle patch for closed-loop dual-hormone delivery in mice and pigs

被引:46
|
作者
Yang, Changwei [1 ]
Sheng, Tao [1 ]
Hou, Wenhui [1 ,2 ]
Zhang, Juan [1 ]
Cheng, Li [1 ]
Wang, Hao [1 ]
Liu, Wei [1 ]
Wang, Shiqi [1 ]
Yu, Xinmin [1 ]
Zhang, Yuqi [1 ,3 ]
Yu, Jicheng [1 ,4 ,5 ,6 ]
Gu, Zhen [1 ,4 ,5 ,6 ,7 ]
机构
[1] Zhejiang Univ, Coll Pharmaceut Sci, Key Lab Adv Drug Delivery Syst Zhejiang Prov, Hangzhou 310058, Peoples R China
[2] Zhejiang Univ Technol, Coll Bioengn, Hangzhou 310014, Peoples R China
[3] Zhejiang Univ, Affiliated Hosp 2, Dept Burns & Wound Ctr, Sch Med, Hangzhou 310009, Peoples R China
[4] Zhejiang Univ, Liangzhu Lab, Med Ctr, Hangzhou 311121, Peoples R China
[5] Zhejiang Univ, Jinhua Inst, Jinhua 321299, Zhejiang, Peoples R China
[6] Zhejiang Univ, Sir Run Run Shaw Hosp, Sch Med, Dept Gen Surg, Hangzhou 310016, Peoples R China
[7] Zhejiang Univ, Dept Polymer Sci & Engn, MOE Key Lab Macromol Synth & Functionalizat, Hangzhou 310027, Peoples R China
来源
SCIENCE ADVANCES | 2022年 / 8卷 / 48期
关键词
DIABETES-MELLITUS; INSULIN DELIVERY; GLUCAGON;
D O I
10.1126/sciadv.add3197
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Insulin and glucagon secreted from the pancreas with dynamic balance play a vital role in regulating blood glucose levels. Although distinct glucose-responsive insulin delivery systems have been developed, the lack of a self-regulated glucagon release module limits their clinical applications due to the potential risk of hypoglycemia. Here, we describe a transdermal polymeric microneedle patch for glucose-responsive closed-loop insulin and glucagon delivery to achieve glycemic regulation with minimized risk of hypoglycemia. The glucose-responsive phenylboronic acid units can bind to glucose to reversibly shift the net charge (from positive to negative) of the entire polymeric matrix within microneedles. Therefore, the release ratio of the negatively charged insulin and the positively charged glucagon analog from the patch can be dynamically tuned upon the fluctuation of blood glucose levels to realize glycemic homeostasis. In both chemically induced type 1 diabetic mouse and minipig models, this glucose-responsive dual-hormone microneedle patch demonstrated tight long-term regulation in blood glucose levels (>24 hours in minipigs).
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Role of Dual-Hormone Closed-Loop Delivery System in the Future
    Bally, Lia
    Thabit, Hood
    Hovorka, Roman
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 (08) : 452 - 454
  • [2] Glucose-Responsive Synthetic Closed-Loop Insulin Delivery Systems
    Zhang Yuqi
    Yu Jicheng
    Shen Qundong
    Gu Zhen
    [J]. PROGRESS IN CHEMISTRY, 2015, 27 (01) : 11 - 26
  • [3] Glucose-Responsive Microgels Integrated with Enzyme Nanocapsules for Closed-Loop Insulin Delivery
    Gu, Zhen
    Dang, Tram T.
    Ma, Minglin
    Tang, Benjamin C.
    Cheng, Hao
    Jiang, Shan
    Dong, Yizhou
    Zhang, Yunlong
    Anderson, Daniel G.
    [J]. ACS NANO, 2013, 7 (08) : 6758 - 6766
  • [4] Shrinking Fabrication of a Glucose-Responsive Glucagon Microneedle Patch
    Wang, Zejun
    Fu, Ruxing
    Han, Xiao
    Wen, Di
    Wu, Yifan
    Li, Song
    Gu, Zhen
    [J]. ADVANCED SCIENCE, 2022, 9 (28)
  • [5] Glucose-Responsive Composite Microneedle Patch for Hypoglycemia-Triggered Delivery of Native Glucagon
    GhavamiNejad, Amin
    Li, Jason
    Lu, Brian
    Zhou, Liwei
    Lam, Loretta
    Giacca, Adria
    Wu, Xiao Yu
    [J]. ADVANCED MATERIALS, 2019, 31 (30)
  • [6] Enzyme coated beta-cyclodextrin for effective adsorption and glucose-responsive closed-loop insulin delivery
    Anirudhan, T. S.
    Nair, Anoop S.
    Nair, Syam S.
    [J]. INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2016, 91 : 818 - 827
  • [7] The effect of degree of acrylic derivatisation on dextran and concanavalin A glucose-responsive materials for closed-loop insulin delivery
    Tanna, Sangeeta
    Sahota, Tarsem S.
    Sawicka, Kirsty
    Taylor, M. Joan
    [J]. BIOMATERIALS, 2006, 27 (25) : 4498 - 4507
  • [8] Estimation and Prediction of Glucose Appearance Rate for Use in a Fully Closed-Loop Dual-Hormone Intraperitoneal Artificial Pancreas
    Benam, Karim Davari
    Gros, Sebastien
    Fougner, Anders Lyngvi
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2024, 71 (01) : 343 - 354
  • [9] Glucose-responsive UV polymerised dextran-concanavalin A acrylic derivatised mixtures for closed-loop insulin delivery
    Tanna, S
    Taylor, MJ
    Sahota, TS
    Sawicka, K
    [J]. BIOMATERIALS, 2006, 27 (08) : 1586 - 1597
  • [10] Microneedle-array patch with pH-sensitive formulation for glucose-responsive insulin delivery
    Luo, Feng-Qin
    Chen, Guojun
    Xu, Wei
    Zhou, Daojia
    Li, Jia-Xian
    Huang, Yong-Cong
    Lin, Run
    Gu, Zhen
    Du, Jin-Zhi
    [J]. NANO RESEARCH, 2021, 14 (08) : 2689 - 2696