Flow Injection Chemiluminescence Sensor with Novel Rhodanine Ramification for Determination of Fenfluramine Based on Molecularly Imprinted Polymer

被引:9
|
作者
Yu Jing-hua [1 ]
Wan Fu-wei [1 ]
Dai Ping [1 ]
Ge Shen-guang [1 ]
Li Bo [1 ]
Huang Jia-dong [1 ]
机构
[1] Univ Jinan, Coll Chem & Chem Engn, Jinan 250022, Peoples R China
关键词
Chemiluminescence; fenfluramine; flow injection; molecularly imprinted polymer (MIP); rhodanine;
D O I
10.1080/00032710902722004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow injection chemiluminescence (FI-CL) with molecularly imprinted polymer (MIP) was applied to determine fenfluramine. The fenfluramine-imprinted polymer was prepared with acrylamide (AM) as functional monomer and ethylene glycol dimethacrylate (EGDMA) as cross-linker. Methyl and sulfonic group were introduced to rhodanine matrix, and a novel rhodanine ramification 3MORASP was synthesized by the author, and it was used as chemiluminescence reagent. 3-(3'-Methoxyphenyl)-5(2'-sulfonylphenylazo)-rhodanine (3MORASP), first synthesized by the authors, was used as chemiluminescence (CL) reagent. The novel flow path of FI-CL was designed, which made three merged streams of reactants injected into MIP column move through different pathways simultaneously. Fenfluramine was detected based on the reaction of fenfluramine, 3MORASP, and potassium permanganate in an acidic medium. The CL intensity was correlated linearly with the concentration of fenfluramine over the range of 1.010-7 to 5.010-6 gmL-1, and the detection limit was 9.4810-9 gmL-1. The relative standard deviation (RSD) was 2.4% for determination of 1.010-6gmL-1 fenfluramine (n=11). This method was successfully applied to the determination of fenfluramine in weight-reducing tonic.
引用
收藏
页码:746 / 757
页数:12
相关论文
共 50 条
  • [1] Quantification of fenfluramine with a molecularly imprinted chemiluminescence sensor and sulfonophenylazo rhodanine
    Yu, Jinghua
    Dai, Ping
    Wan, Fuwei
    Li, Bo
    Ge, Shenguang
    [J]. JOURNAL OF SEPARATION SCIENCE, 2009, 32 (12) : 2170 - 2179
  • [2] Determination of Amoxicillin with Novel Rhodanine Ramification by Flow Injection Chemiluminescence
    Yu Jing-hua
    Wan Fu-wei
    Dai Ping
    Huang Jia-dong
    Cui Jian-jie
    [J]. 2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 4405 - +
  • [3] Determination of Ascorbic Acid with Novel Rhodanine Ramification by Flow Injection Chemiluminescence
    Wan, Fu wei
    Yu, Jin hua
    Yan, Mei
    Ge, Shen guang
    Zhang, Cong cong
    [J]. LUMINESCENCE, 2010, 25 (02) : 99 - 100
  • [4] Flow chemiluminescence sensor for determination of clenbuterol based on molecularly imprinted polymer
    Zhou, HJ
    Zhang, ZJ
    He, DY
    Hu, YF
    Huang, Y
    Chen, DL
    [J]. ANALYTICA CHIMICA ACTA, 2004, 523 (02) : 237 - 242
  • [5] Flow-injection chemiluminescence sensor for determination of isoniazid in urine sample based on molecularly imprinted polymer
    Xiong, Yan
    Zhou, Houjiang
    Zhang, Zhujun
    He, Deyong
    He, Chao
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2007, 66 (02) : 341 - 346
  • [6] Determination of hydralazine with flow injection chemiluminescence sensor using molecularly imprinted polymer as recognition element
    Xiong, Yan
    Zhou, Houjiang
    Zhang, Zhujun
    He, Deyong
    He, Chao
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (03) : 694 - 700
  • [7] A chemiluminescence sensor based on molecularly imprinted polymer for determination of peimine
    Han, Hongping
    Zheng, Hong
    Li, Baolin
    Xiang, Hui
    Zhangluo, Yilan
    [J]. INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2017, 56 (05): : 501 - 507
  • [8] A Novel Chemiluminescence Array Sensor Based on Molecularly Imprinted Polymer
    Chang Pingping
    Zhang Zhujun
    [J]. ACTA CHIMICA SINICA, 2009, 67 (23) : 2727 - 2731
  • [9] Molecularly imprinted polymeric microspheres for determination of bovine serum albumin based on flow injection chemiluminescence sensor
    Yu Jinghua
    Wan Fuwei
    Zhang Congcong
    Yan Mei
    Zhang Xiaona
    Wang Shaowei
    [J]. BIOSENSORS & BIOELECTRONICS, 2010, 26 (02): : 632 - 637
  • [10] Micro flow sensor on a chip for the determination of terbutaline in human serum based on chemiluminescence and a molecularly imprinted polymer
    He, Deyong
    Zhang, Zhujun
    Zhou, Houjiang
    Huang, Ying
    [J]. TALANTA, 2006, 69 (05) : 1215 - 1220