Simultaneous Quantification of Five Bioactive Components of Acanthopanax senticosus and Its Extract by Ultra Performance Liquid Chromatography with Electrospray Ionization Time-of-Flight Mass Spectrometry

被引:20
|
作者
Liu, Shi-Ping [1 ]
An, Jing-Tao [2 ]
Wang, Rui [3 ]
Li, Qiang [4 ]
机构
[1] Harbin Med Univ, Affiliated Hosp 1, Dept Pharm, Harbin 150001, Peoples R China
[2] Harbin Med Univ, Sch Stomatol, Dept Orthodont, Harbin 150001, Peoples R China
[3] Harbin Med Univ, Sch Stomatol, Dept Pediat, Harbin 150001, Peoples R China
[4] Beijing Univ Chinese Med, Coll Pharm, Beijing 100029, Peoples R China
来源
MOLECULES | 2012年 / 17卷 / 07期
关键词
Acanthopanax senticosus; Acanthopanax extract; UPLC-TOF-MS; quantitative analysis; ISOFRAXIDIN;
D O I
10.3390/molecules17077903
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A simple and reliable ultra performance liquid chromatography coupled with electrospray ionization time-of-flight mass spectrometry method (UPLC-TOF-MS) was developed and validated for the simultaneous determination of the major bioactive constituents in Acanthopanax senticosus and its extract. The separation of five compounds was performed on a UPLC (TM) HSS T3 column (100 mm x 2.1 mm, 1.7 mu m) with gradient elution using a mobile phase consisting of 0.1% aqueous formic acid and acetonitrile containing 0.1% formic acid. All targeted compounds (syringin, chlorogenid acid, caffeic acid, eleutheroside E and isofraxidin) were baseline separated within 5.3 min in samples, which represented an approximate six-fold reduction in the analysis time in comparison to published HPLC method. Quantitation was carried out working in the V mode using the narrow widow extracted ion chromatograms (nwXICs) of each compound (extracted using a 20 mDa window). Furthermore, all calibration curves showed good linearity (r > 0.999) within the test ranges. The precision was evaluated by intra-and inter-day tests, which revealed relative standard deviation (RSD) values of less than 3.88%. The recoveries for the quantified compounds were between 96.3% and 103.7%, with RSD values below 2.89%. According to the literature, this study represents the first investigation of the simultaneous analysis of multiple components and the method can be applied to determine the amounts of the major compounds in Acanthopanax senticosus and its extract by UPLC-TOF-MS.
引用
收藏
页码:7903 / 7913
页数:11
相关论文
共 50 条
  • [1] Characterization of the multiple components of Acanthopanax Senticosus stem by ultra high performance liquid chromatography with quadrupole time-of-flight tandem mass spectrometry
    Sun, Hui
    Liu, Jianhua
    Zhang, Aihua
    Zhang, Ying
    Meng, Xiangcai
    Han, Ying
    Zhang, Yingzhi
    Wang, Xijun
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (03) : 496 - 502
  • [2] Polymer analysis by liquid chromatography electrospray ionization time-of-flight mass spectrometry
    Nielen, MWF
    Buijtenhuijs, FA
    ANALYTICAL CHEMISTRY, 1999, 71 (09) : 1809 - 1814
  • [3] Fragmentation patterns of five types of phospholipids by ultra-high-performance liquid chromatography electrospray ionization quadrupole time-of-flight tandem mass spectrometry
    Pi, Juanjuan
    Wu, Xia
    Feng, Yifan
    ANALYTICAL METHODS, 2016, 8 (06) : 1319 - 1332
  • [4] Characterization of polyethermethylsiloxanes using ultra-high performance liquid chromatography-electrospray ionization and time-of-flight mass spectrometry
    Yin, Changna
    Fu, Jie
    Lu, Xiuyang
    ANALYTICA CHIMICA ACTA, 2019, 1082 : 194 - 201
  • [5] Simultaneous quantification of eight major constituents in Herba Siegesbeckiae by liquid chromatography coupled with electrospray ionization time-of-flight tandem mass spectrometry
    Jiang, Zhen
    Yu, Qing-Hong
    Cheng, Yan
    Guo, Xing-Jie
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (03) : 452 - 457
  • [6] Application of Ultra-performance Liquid Chromatography with Time-of-Flight Mass Spectrometry for the Rapid Analysis of Constituents and Metabolites from the Extracts of Acanthopanax senticosus Harms Leaf
    Zhang, Yingzhi
    Zhang, Aihua
    Zhang, Ying
    Sun, Hui
    Meng, Xiangcai
    Yan, Guangli
    Wang, Xijun
    PHARMACOGNOSY MAGAZINE, 2016, 12 (46) : 145 - 152
  • [7] High performance liquid chromatography time of flight electrospray ionization mass spectrometry for quantification of sesquiterpenes in Chrysanthemi indici Flos active extract
    Fu, Ling
    Wang, Pan
    Sun, Yiqun
    Wang, Yangyang
    Zhao, Jing
    Ye, Yuting
    Zhang, Yanbin
    Bi, Yuefeng
    PHARMACOGNOSY MAGAZINE, 2015, 11 (44) : 740 - 744
  • [8] Improving mass accuracy of high performance liquid chromatography/electrospray ionization time-of-flight mass spectrometry of intact antibodies
    Gadgil, Himanshu S.
    Pipes, Gary D.
    Dillon, Thomas M.
    Treuheit, Michael J.
    Bondarenko, Pavel V.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (06) : 867 - 872
  • [9] Improving Mass Accuracy of High Performance Liquid Chromatography/Electrospray Ionization Time-of-Flight Mass Spectrometry of Intact Antibodies
    Gadgil, Himanshu S.
    Pipes, Gary D.
    Dillon, Thomas M.
    Treuheit, Michael J.
    Bondarenko, Pavel V.
    Journal of the American Society for Mass Spectrometry, 2006, 17 (06): : 867 - 872
  • [10] Metabolic profiling of rat hair and screening biomarkers using ultra performance liquid chromatography with electrospray ionization time-of-flight mass spectrometry
    Inagaki, Shinsuke
    Noda, Takumi
    Min, Jun Zhe
    Toyo'oka, Toshimasa
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1176 (1-2) : 94 - 99